肉鸡非接触式生命体征监测

Md. Shafkat Hossain, Sourav Kumar Pramanik, Atikur Rahman, Shahin Ali, Shekh Md Mahmudul Islam
{"title":"肉鸡非接触式生命体征监测","authors":"Md. Shafkat Hossain, Sourav Kumar Pramanik, Atikur Rahman, Shahin Ali, Shekh Md Mahmudul Islam","doi":"10.1049/tje2.12320","DOIUrl":null,"url":null,"abstract":"Abstract Measuring the heartbeat and respiration of animals continuously can provide valuable information about their health status. Respiratory‐related diseases are very common in the poultry industry and unfortunately, there is no non‐contact respiratory monitoring system for measuring the breathing rate and heart rate of the broiler chicken. In this letter, the authors explored and tested the feasibility of utilizing a 24‐GHz continuous‐wave (CW) radar module for monitoring the vital signs (breathing rate and heart rate) of broiler chickens. A signal processing approach has been developed to extract vital signs of broiler chicken from Radar‐captured signals. The experiment was carried out on three different normal broiler chickens with the ages of 25–30 days, weight 1.18–1.6 kg where a 24‐GHz radar module was mounted at a distance of 0.2 m above the chest surface of the chicken, and this particular experiment was repeated for 20 times. The authors also used a reference ECG module (Biopac System) for extracting the breathing rate and heart rate of the broiler chicken and compared the accuracy of their proposed system. Experimental results demonstrated that the radar measurement closely matches the Biopac ECG acquisition module measurement and showed an accuracy of 96% for a short‐scale study.","PeriodicalId":22858,"journal":{"name":"The Journal of Engineering","volume":"90 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Non‐contact vital signs monitoring in broiler chickens\",\"authors\":\"Md. Shafkat Hossain, Sourav Kumar Pramanik, Atikur Rahman, Shahin Ali, Shekh Md Mahmudul Islam\",\"doi\":\"10.1049/tje2.12320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Measuring the heartbeat and respiration of animals continuously can provide valuable information about their health status. Respiratory‐related diseases are very common in the poultry industry and unfortunately, there is no non‐contact respiratory monitoring system for measuring the breathing rate and heart rate of the broiler chicken. In this letter, the authors explored and tested the feasibility of utilizing a 24‐GHz continuous‐wave (CW) radar module for monitoring the vital signs (breathing rate and heart rate) of broiler chickens. A signal processing approach has been developed to extract vital signs of broiler chicken from Radar‐captured signals. The experiment was carried out on three different normal broiler chickens with the ages of 25–30 days, weight 1.18–1.6 kg where a 24‐GHz radar module was mounted at a distance of 0.2 m above the chest surface of the chicken, and this particular experiment was repeated for 20 times. The authors also used a reference ECG module (Biopac System) for extracting the breathing rate and heart rate of the broiler chicken and compared the accuracy of their proposed system. Experimental results demonstrated that the radar measurement closely matches the Biopac ECG acquisition module measurement and showed an accuracy of 96% for a short‐scale study.\",\"PeriodicalId\":22858,\"journal\":{\"name\":\"The Journal of Engineering\",\"volume\":\"90 6\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/tje2.12320\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/tje2.12320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

持续测量动物的心跳和呼吸可以提供有价值的健康状况信息。呼吸相关疾病在家禽业中非常常见,不幸的是,没有非接触呼吸监测系统来测量肉鸡的呼吸频率和心率。在这封信中,作者探索并测试了利用24 GHz连续波(CW)雷达模块监测肉鸡生命体征(呼吸频率和心率)的可行性。从雷达捕获的信号中提取肉鸡生命体征的信号处理方法已经被开发出来。本试验以3只25 ~ 30日龄、体重1.18 ~ 1.6 kg的正常肉鸡为试验对象,在鸡胸表面上方0.2 m处安装24 GHz雷达模块,重复试验20次。作者还使用参考心电图模块(Biopac系统)来提取肉鸡的呼吸率和心率,并比较了他们提出的系统的准确性。实验结果表明,雷达测量与Biopac ECG采集模块测量结果非常接近,在短尺度研究中准确率达到96%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Non‐contact vital signs monitoring in broiler chickens
Abstract Measuring the heartbeat and respiration of animals continuously can provide valuable information about their health status. Respiratory‐related diseases are very common in the poultry industry and unfortunately, there is no non‐contact respiratory monitoring system for measuring the breathing rate and heart rate of the broiler chicken. In this letter, the authors explored and tested the feasibility of utilizing a 24‐GHz continuous‐wave (CW) radar module for monitoring the vital signs (breathing rate and heart rate) of broiler chickens. A signal processing approach has been developed to extract vital signs of broiler chicken from Radar‐captured signals. The experiment was carried out on three different normal broiler chickens with the ages of 25–30 days, weight 1.18–1.6 kg where a 24‐GHz radar module was mounted at a distance of 0.2 m above the chest surface of the chicken, and this particular experiment was repeated for 20 times. The authors also used a reference ECG module (Biopac System) for extracting the breathing rate and heart rate of the broiler chicken and compared the accuracy of their proposed system. Experimental results demonstrated that the radar measurement closely matches the Biopac ECG acquisition module measurement and showed an accuracy of 96% for a short‐scale study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel jittered‐carrier phase‐shifted sine pulse width modulation for cascaded H‐bridge converter An improved hybrid network‐on‐chip with flexible topology and frugal routing Magnetic sensors for contactless and non‐intrusive measurement of current in AC power systems Regulation of mixed convective flow in a horizontal channel with multiple slots using P, PI, and PID controllers BrutNet: A novel approach for violence detection and classification using DCNN with GRU
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1