Roro Prasti Hapsari, Hidajat Sugihardjo, Ahmad Basshofi Habieb
{"title":"非工程建筑砌筑墙缝角穿孔板性能研究","authors":"Roro Prasti Hapsari, Hidajat Sugihardjo, Ahmad Basshofi Habieb","doi":"10.12962/j20861206.v38i2.17451","DOIUrl":null,"url":null,"abstract":"Indonesian houses are characterized as non-engineered and vernacular, constructed using local material, techniques, and architectural style. As a results these houses are typically built without the involvement of experts. In Indonesia, most lower class houses are unreinforced masonry (URM), masonry without structural elements. The absence of structural elements makes URM highly vulnerable to earthquakes and makes the masonry walls the main load bearers. This study analyses the performance of corner joint masonry wall with perforated plate to enhance the integrity between the perpendicular walls. This research was carried out experimentally. The results indicate that URM joint corner walls without perforated plates has the highest load capacity and ductility. Perforated plates in layers of masonry walls can decrease the lateral load capacity by 55%. The failure pattern occurred are slip failure, with cracks appearing at mortar-brick joint and mortar-perforated plate interfaces. From the test that have been carried out, it was found that perforated plate could reduce the cohesiveness of the walls rather than enhance the integrity of the perpendicular walls.","PeriodicalId":9414,"journal":{"name":"Canadian Journal of Civil Engineering","volume":"54 1","pages":"0"},"PeriodicalIF":1.1000,"publicationDate":"2023-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PERFORMANCE OF MASONRY WALL JOINT CORNER WITH PERFORATED PLATE IN NON-ENGINEERING BUILDING\",\"authors\":\"Roro Prasti Hapsari, Hidajat Sugihardjo, Ahmad Basshofi Habieb\",\"doi\":\"10.12962/j20861206.v38i2.17451\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Indonesian houses are characterized as non-engineered and vernacular, constructed using local material, techniques, and architectural style. As a results these houses are typically built without the involvement of experts. In Indonesia, most lower class houses are unreinforced masonry (URM), masonry without structural elements. The absence of structural elements makes URM highly vulnerable to earthquakes and makes the masonry walls the main load bearers. This study analyses the performance of corner joint masonry wall with perforated plate to enhance the integrity between the perpendicular walls. This research was carried out experimentally. The results indicate that URM joint corner walls without perforated plates has the highest load capacity and ductility. Perforated plates in layers of masonry walls can decrease the lateral load capacity by 55%. The failure pattern occurred are slip failure, with cracks appearing at mortar-brick joint and mortar-perforated plate interfaces. From the test that have been carried out, it was found that perforated plate could reduce the cohesiveness of the walls rather than enhance the integrity of the perpendicular walls.\",\"PeriodicalId\":9414,\"journal\":{\"name\":\"Canadian Journal of Civil Engineering\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Journal of Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12962/j20861206.v38i2.17451\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12962/j20861206.v38i2.17451","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
PERFORMANCE OF MASONRY WALL JOINT CORNER WITH PERFORATED PLATE IN NON-ENGINEERING BUILDING
Indonesian houses are characterized as non-engineered and vernacular, constructed using local material, techniques, and architectural style. As a results these houses are typically built without the involvement of experts. In Indonesia, most lower class houses are unreinforced masonry (URM), masonry without structural elements. The absence of structural elements makes URM highly vulnerable to earthquakes and makes the masonry walls the main load bearers. This study analyses the performance of corner joint masonry wall with perforated plate to enhance the integrity between the perpendicular walls. This research was carried out experimentally. The results indicate that URM joint corner walls without perforated plates has the highest load capacity and ductility. Perforated plates in layers of masonry walls can decrease the lateral load capacity by 55%. The failure pattern occurred are slip failure, with cracks appearing at mortar-brick joint and mortar-perforated plate interfaces. From the test that have been carried out, it was found that perforated plate could reduce the cohesiveness of the walls rather than enhance the integrity of the perpendicular walls.
期刊介绍:
The Canadian Journal of Civil Engineering is the official journal of the Canadian Society for Civil Engineering. It contains articles on environmental engineering, hydrotechnical engineering, structural engineering, construction engineering, engineering mechanics, engineering materials, and history of civil engineering. Contributors include recognized researchers and practitioners in industry, government, and academia. New developments in engineering design and construction are also featured.