计算和测量imp和凹坑:为什么精确的计数极其罕见。

J E Rash, F D Giddings
{"title":"计算和测量imp和凹坑:为什么精确的计数极其罕见。","authors":"J E Rash,&nbsp;F D Giddings","doi":"10.1002/jemt.1060130307","DOIUrl":null,"url":null,"abstract":"<p><p>Particle counting and measuring techniques are now widely used to characterize normal membranes and to identify molecular changes occurring during development, maturation, and aging during progression of disease and following pharmacological manipulation. However, the use of particle counting and measuring for the identification of molecular changes in membranes has been premature. We show that current procedures rarely yield replicas that are free of cryogenic or mechanical prefractures, and as a result, the \"complementarity\" of membrane faces is severely compromised. However, with simple alterations of procedure, combined with the resolve to recognize and discard images of pre-fractured membrane faces, a high degree of \"complementarity\" may be obtained. Criteria for recognizing the occurrence and relative frequency of noncomplementarity are presented and a cleaving method for avoiding a primary source of water vapor contamination is described. In such replicas, membrane pits are found in equivalent numbers and near-identical diameters as the intramembrane particles (IMPs) in the complementary-type membrane faces. When conditions of \"cold fracture\" and immediate replication are demonstrated, fracture faces are minimally contaminated by frozen water vapor, yielding images where 1) diameters of IMPs vs. pits are very nearly identical, 2) large diameter IMPs are very rare, and 3) the numbers of IMPs and pits are increased substantially over the numbers currently reported. Thus, we reiterate previous proposals that complementarity of membrane faces is the single most important criterion that must be met before accepting the validity of IMP counts or for attributing perceived changes in IMP density or size to conditions of experimental manipulation, to normal developmental processes, or to disease etiology.</p>","PeriodicalId":15690,"journal":{"name":"Journal of electron microscopy technique","volume":"13 3","pages":"204-15"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/jemt.1060130307","citationCount":"8","resultStr":"{\"title\":\"Counting and measuring IMPs and pits: why accurate counts are exceedingly rare.\",\"authors\":\"J E Rash,&nbsp;F D Giddings\",\"doi\":\"10.1002/jemt.1060130307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Particle counting and measuring techniques are now widely used to characterize normal membranes and to identify molecular changes occurring during development, maturation, and aging during progression of disease and following pharmacological manipulation. However, the use of particle counting and measuring for the identification of molecular changes in membranes has been premature. We show that current procedures rarely yield replicas that are free of cryogenic or mechanical prefractures, and as a result, the \\\"complementarity\\\" of membrane faces is severely compromised. However, with simple alterations of procedure, combined with the resolve to recognize and discard images of pre-fractured membrane faces, a high degree of \\\"complementarity\\\" may be obtained. Criteria for recognizing the occurrence and relative frequency of noncomplementarity are presented and a cleaving method for avoiding a primary source of water vapor contamination is described. In such replicas, membrane pits are found in equivalent numbers and near-identical diameters as the intramembrane particles (IMPs) in the complementary-type membrane faces. When conditions of \\\"cold fracture\\\" and immediate replication are demonstrated, fracture faces are minimally contaminated by frozen water vapor, yielding images where 1) diameters of IMPs vs. pits are very nearly identical, 2) large diameter IMPs are very rare, and 3) the numbers of IMPs and pits are increased substantially over the numbers currently reported. Thus, we reiterate previous proposals that complementarity of membrane faces is the single most important criterion that must be met before accepting the validity of IMP counts or for attributing perceived changes in IMP density or size to conditions of experimental manipulation, to normal developmental processes, or to disease etiology.</p>\",\"PeriodicalId\":15690,\"journal\":{\"name\":\"Journal of electron microscopy technique\",\"volume\":\"13 3\",\"pages\":\"204-15\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/jemt.1060130307\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of electron microscopy technique\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/jemt.1060130307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electron microscopy technique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/jemt.1060130307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

颗粒计数和测量技术现在广泛用于表征正常膜,并识别在发育、成熟、疾病进展和药物操作过程中发生的分子变化。然而,使用颗粒计数和测量来识别膜中的分子变化还为时过早。我们发现,目前的方法很少产生没有低温或机械预断裂的复制品,因此,膜表面的“互补性”受到严重损害。然而,通过简单的程序改变,结合识别和丢弃预破裂膜面图像的决心,可以获得高度的“互补性”。提出了识别非互补性发生和相对频率的标准,并描述了一种避免水蒸气污染主要来源的切割方法。在这样的复制品中,发现膜坑与互补型膜表面的膜内颗粒(IMPs)具有相同的数量和几乎相同的直径。当“冷断裂”和立即复制的条件被证明时,裂缝面被冷冻水蒸气污染的程度最低,产生的图像中,1)imp和凹坑的直径非常接近,2)大直径imp非常罕见,3)imp和凹坑的数量比目前报道的数量大大增加。因此,我们重申先前的建议,即在接受IMP计数的有效性或将IMP密度或大小的感知变化归因于实验操作条件、正常发育过程或疾病病因之前,必须满足膜面互补性是唯一最重要的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Counting and measuring IMPs and pits: why accurate counts are exceedingly rare.

Particle counting and measuring techniques are now widely used to characterize normal membranes and to identify molecular changes occurring during development, maturation, and aging during progression of disease and following pharmacological manipulation. However, the use of particle counting and measuring for the identification of molecular changes in membranes has been premature. We show that current procedures rarely yield replicas that are free of cryogenic or mechanical prefractures, and as a result, the "complementarity" of membrane faces is severely compromised. However, with simple alterations of procedure, combined with the resolve to recognize and discard images of pre-fractured membrane faces, a high degree of "complementarity" may be obtained. Criteria for recognizing the occurrence and relative frequency of noncomplementarity are presented and a cleaving method for avoiding a primary source of water vapor contamination is described. In such replicas, membrane pits are found in equivalent numbers and near-identical diameters as the intramembrane particles (IMPs) in the complementary-type membrane faces. When conditions of "cold fracture" and immediate replication are demonstrated, fracture faces are minimally contaminated by frozen water vapor, yielding images where 1) diameters of IMPs vs. pits are very nearly identical, 2) large diameter IMPs are very rare, and 3) the numbers of IMPs and pits are increased substantially over the numbers currently reported. Thus, we reiterate previous proposals that complementarity of membrane faces is the single most important criterion that must be met before accepting the validity of IMP counts or for attributing perceived changes in IMP density or size to conditions of experimental manipulation, to normal developmental processes, or to disease etiology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Real time computer simulation of transmission electron microscope images with tilted illumination: grain boundary applications. Cryofixation of vascular endothelium. The endothelial vesicle system in cryofixed frog mesenteric capillaries analysed by ultrathin serial sectioning. Lectin and immunolabeling of microvascular endothelia. Quick-freeze, deep-etch studies of endothelial components, with special reference to cytoskeletons and vesicle structures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1