粘合剂活化对多层碳纤维织物叠层中平面内毛细流动的影响

IF 2.3 4区 材料科学 Q3 MATERIALS SCIENCE, COMPOSITES Applied Composite Materials Pub Date : 2023-12-21 DOI:10.1007/s10443-023-10198-6
Stefan Neunkirchen, Marcel Bender, Ralf Schledjewski
{"title":"粘合剂活化对多层碳纤维织物叠层中平面内毛细流动的影响","authors":"Stefan Neunkirchen,&nbsp;Marcel Bender,&nbsp;Ralf Schledjewski","doi":"10.1007/s10443-023-10198-6","DOIUrl":null,"url":null,"abstract":"<div><p>Binder/tackifier materials are commonly used in preforming processes to preserve the structural integrity of the preform during processing. In the following resin infusion or injection process, this additional material will influence the resin flow. While the influence on fabric permeability is thoroughly examined in scientific literature, only few studies investigate the capillary behavior. By thermal activation of the binder, the material melts and spreads across the layer’s surface or is imbibed by the rovings.</p><p>In this study, capillary rise experiments in planar direction with four different carbon fiber fabrics were performed. The tested stacks were activated at different temperature levels and compressed in a vacuum bag, one of them with additional external pressure in an autoclave. In case of no external pressure, the processing and testing conditions showed a larger influence than binder activation temperature, while autoclave-conditioned specimens showed a decreased capillary rise velocity for all levels of activation temperature. Digital microscopy images of the specimens show that molten binder can create a thin film between the layers, which prevents peripheral flow and thus forces the fluid to rise in the (angulated) capillary tubes inside the rovings.</p></div>","PeriodicalId":468,"journal":{"name":"Applied Composite Materials","volume":"31 2","pages":"709 - 719"},"PeriodicalIF":2.3000,"publicationDate":"2023-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10443-023-10198-6.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of Binder Activation on in-Plane Capillary Flow in Multilayer Stacks of Carbon Fiber Fabrics\",\"authors\":\"Stefan Neunkirchen,&nbsp;Marcel Bender,&nbsp;Ralf Schledjewski\",\"doi\":\"10.1007/s10443-023-10198-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Binder/tackifier materials are commonly used in preforming processes to preserve the structural integrity of the preform during processing. In the following resin infusion or injection process, this additional material will influence the resin flow. While the influence on fabric permeability is thoroughly examined in scientific literature, only few studies investigate the capillary behavior. By thermal activation of the binder, the material melts and spreads across the layer’s surface or is imbibed by the rovings.</p><p>In this study, capillary rise experiments in planar direction with four different carbon fiber fabrics were performed. The tested stacks were activated at different temperature levels and compressed in a vacuum bag, one of them with additional external pressure in an autoclave. In case of no external pressure, the processing and testing conditions showed a larger influence than binder activation temperature, while autoclave-conditioned specimens showed a decreased capillary rise velocity for all levels of activation temperature. Digital microscopy images of the specimens show that molten binder can create a thin film between the layers, which prevents peripheral flow and thus forces the fluid to rise in the (angulated) capillary tubes inside the rovings.</p></div>\",\"PeriodicalId\":468,\"journal\":{\"name\":\"Applied Composite Materials\",\"volume\":\"31 2\",\"pages\":\"709 - 719\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s10443-023-10198-6.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Composite Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10443-023-10198-6\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MATERIALS SCIENCE, COMPOSITES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Composite Materials","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s10443-023-10198-6","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MATERIALS SCIENCE, COMPOSITES","Score":null,"Total":0}
引用次数: 0

摘要

预成型工艺中通常使用粘合剂/增粘材料,以保持预成型件在加工过程中的结构完整性。在接下来的树脂灌注或注射过程中,这种附加材料会影响树脂流动。虽然科学文献对织物渗透性的影响进行了深入研究,但只有少数研究对毛细管行为进行了调查。在本研究中,对四种不同的碳纤维织物进行了平面方向的毛细管上升实验。在不同的温度水平下,测试的叠层被激活并在真空袋中压缩,其中一个真空袋在高压灭菌器中带有额外的外部压力。在无外部压力的情况下,加工和测试条件比粘合剂活化温度的影响更大,而经过高压灭菌器处理的试样在所有活化温度下的毛细管上升速度都有所下降。试样的数码显微镜图像显示,熔融粘结剂可在层间形成一层薄膜,阻止外围流动,从而迫使流体在粗纱内部的(成角度的)毛细管中上升。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Binder Activation on in-Plane Capillary Flow in Multilayer Stacks of Carbon Fiber Fabrics

Binder/tackifier materials are commonly used in preforming processes to preserve the structural integrity of the preform during processing. In the following resin infusion or injection process, this additional material will influence the resin flow. While the influence on fabric permeability is thoroughly examined in scientific literature, only few studies investigate the capillary behavior. By thermal activation of the binder, the material melts and spreads across the layer’s surface or is imbibed by the rovings.

In this study, capillary rise experiments in planar direction with four different carbon fiber fabrics were performed. The tested stacks were activated at different temperature levels and compressed in a vacuum bag, one of them with additional external pressure in an autoclave. In case of no external pressure, the processing and testing conditions showed a larger influence than binder activation temperature, while autoclave-conditioned specimens showed a decreased capillary rise velocity for all levels of activation temperature. Digital microscopy images of the specimens show that molten binder can create a thin film between the layers, which prevents peripheral flow and thus forces the fluid to rise in the (angulated) capillary tubes inside the rovings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Composite Materials
Applied Composite Materials 工程技术-材料科学:复合
CiteScore
4.20
自引率
4.30%
发文量
81
审稿时长
1.6 months
期刊介绍: Applied Composite Materials is an international journal dedicated to the publication of original full-length papers, review articles and short communications of the highest quality that advance the development and application of engineering composite materials. Its articles identify problems that limit the performance and reliability of the composite material and composite part; and propose solutions that lead to innovation in design and the successful exploitation and commercialization of composite materials across the widest spectrum of engineering uses. The main focus is on the quantitative descriptions of material systems and processing routes. Coverage includes management of time-dependent changes in microscopic and macroscopic structure and its exploitation from the material''s conception through to its eventual obsolescence.
期刊最新文献
A Coupled Elastoplastic-Damage Analytical Model for 3D Resin-Matrix Woven Composites Effect of Temperature on the Mixed mode I/II Translaminar Fracture of Epoxy Composites Reinforced with Cotton Fibers Experimental Characterisation of Cure-Dependent Spring-Back Behaviour of Metal-Composite Laminates in a Hot-Pressing Process Cutting Force Model of SiCp/Al Composites in Ultrasonic Elliptical Vibration Assisted Cutting with Negative Rake Angle Experimental and Simulation Analysis of the Mechanical Deterioration Mechanisms in SiCp/A356 Composites Under Thermal Cycling Load
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1