{"title":"将深度强化学习应用于现有商业楼宇空气处理机组系统的比例-积分-微分控制器调整","authors":"Dongkyu Lee, Jinhwa Jeong, Young Tae Chae","doi":"10.3390/buildings14010066","DOIUrl":null,"url":null,"abstract":"An effective control of air handling unit (AHU) systems is crucial not only for managing the energy consumption of buildings but ensuring indoor thermal comfort for occupants. Although the initial control schema of AHU is appropriate at installation and testing, it is frequently necessary to adjust the control variables due to the changing thermal response of the building envelope and space usage. This paper presents a novel optimization process for the control parameters of old AHU systems in existing commercial buildings without system downtime and massive operational data. First, calibrating the building and system simulator with limited system operation data and unknown building parameters can provide identical responses to the system operation with the Hooke–Jeeves algorithm during the cooling season. The deep deterministic policy gradient algorithm is employed to determine the optimal control parameters for the valve opening position of the cooling coil within less than three hours of training based on the calibrated simulator. By using actual implementations with the developed optimal control variables for an old AHU in a real building, the proposed auto-tuned PID control in the simulator and with machine learning improves thermal environments with a steady room temperature (23.5 ± 0.5 °C) by 97% in occupied periods. It is also proved that this can reduce cooling energy consumption by up to 13.71% on a daily average. The successful AHU controller can improve not only the stability of AHU systems but the efficiency of a building’s energy use and indoor thermal comfort.","PeriodicalId":48546,"journal":{"name":"Buildings","volume":"14 4","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2023-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of Deep Reinforcement Learning for Proportional–Integral–Derivative Controller Tuning on Air Handling Unit System in Existing Commercial Building\",\"authors\":\"Dongkyu Lee, Jinhwa Jeong, Young Tae Chae\",\"doi\":\"10.3390/buildings14010066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An effective control of air handling unit (AHU) systems is crucial not only for managing the energy consumption of buildings but ensuring indoor thermal comfort for occupants. Although the initial control schema of AHU is appropriate at installation and testing, it is frequently necessary to adjust the control variables due to the changing thermal response of the building envelope and space usage. This paper presents a novel optimization process for the control parameters of old AHU systems in existing commercial buildings without system downtime and massive operational data. First, calibrating the building and system simulator with limited system operation data and unknown building parameters can provide identical responses to the system operation with the Hooke–Jeeves algorithm during the cooling season. The deep deterministic policy gradient algorithm is employed to determine the optimal control parameters for the valve opening position of the cooling coil within less than three hours of training based on the calibrated simulator. By using actual implementations with the developed optimal control variables for an old AHU in a real building, the proposed auto-tuned PID control in the simulator and with machine learning improves thermal environments with a steady room temperature (23.5 ± 0.5 °C) by 97% in occupied periods. It is also proved that this can reduce cooling energy consumption by up to 13.71% on a daily average. The successful AHU controller can improve not only the stability of AHU systems but the efficiency of a building’s energy use and indoor thermal comfort.\",\"PeriodicalId\":48546,\"journal\":{\"name\":\"Buildings\",\"volume\":\"14 4\",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2023-12-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Buildings\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/buildings14010066\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Buildings","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/buildings14010066","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Application of Deep Reinforcement Learning for Proportional–Integral–Derivative Controller Tuning on Air Handling Unit System in Existing Commercial Building
An effective control of air handling unit (AHU) systems is crucial not only for managing the energy consumption of buildings but ensuring indoor thermal comfort for occupants. Although the initial control schema of AHU is appropriate at installation and testing, it is frequently necessary to adjust the control variables due to the changing thermal response of the building envelope and space usage. This paper presents a novel optimization process for the control parameters of old AHU systems in existing commercial buildings without system downtime and massive operational data. First, calibrating the building and system simulator with limited system operation data and unknown building parameters can provide identical responses to the system operation with the Hooke–Jeeves algorithm during the cooling season. The deep deterministic policy gradient algorithm is employed to determine the optimal control parameters for the valve opening position of the cooling coil within less than three hours of training based on the calibrated simulator. By using actual implementations with the developed optimal control variables for an old AHU in a real building, the proposed auto-tuned PID control in the simulator and with machine learning improves thermal environments with a steady room temperature (23.5 ± 0.5 °C) by 97% in occupied periods. It is also proved that this can reduce cooling energy consumption by up to 13.71% on a daily average. The successful AHU controller can improve not only the stability of AHU systems but the efficiency of a building’s energy use and indoor thermal comfort.
期刊介绍:
BUILDINGS content is primarily staff-written and submitted information is evaluated by the editors for its value to the audience. Such information may be used in articles with appropriate attribution to the source. The editorial staff considers information on the following topics: -Issues directed at building owners and facility managers in North America -Issues relevant to existing buildings, including retrofits, maintenance and modernization -Solution-based content, such as tips and tricks -New construction but only with an eye to issues involving maintenance and operation We generally do not review the following topics because these are not relevant to our readers: -Information on the residential market with the exception of multifamily buildings -International news unrelated to the North American market -Real estate market updates or construction updates