使用基于样品压缩测功机的测量装置校准基斯勒压电测功机

A. S. Karelsky, A. R. Maslov
{"title":"使用基于样品压缩测功机的测量装置校准基斯勒压电测功机","authors":"A. S. Karelsky, A. R. Maslov","doi":"10.14489/td.2023.10.pp.050-053","DOIUrl":null,"url":null,"abstract":"Establishing the error values of instruments with other control instruments that give correct readings by identifying and documenting differences between readings is a common method. A description of the measuring device for direct measurement of basic properties of technological equipment characterizing the accuracy of force measurement by a laboratory dynamometer. A measurement method is used, in which the desired value is determined directly by the displaying measuring instrument. The device is reconfigured by changing the included modules.","PeriodicalId":432853,"journal":{"name":"Kontrol'. Diagnostika","volume":"25 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CALIBRATION OF THE PIEZOELECTRIC DYNAMOMETER KISTLER USING A MEASURING DEVICE BASED ON A SAMPLE COMPRESSION DYNAMOMETER\",\"authors\":\"A. S. Karelsky, A. R. Maslov\",\"doi\":\"10.14489/td.2023.10.pp.050-053\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Establishing the error values of instruments with other control instruments that give correct readings by identifying and documenting differences between readings is a common method. A description of the measuring device for direct measurement of basic properties of technological equipment characterizing the accuracy of force measurement by a laboratory dynamometer. A measurement method is used, in which the desired value is determined directly by the displaying measuring instrument. The device is reconfigured by changing the included modules.\",\"PeriodicalId\":432853,\"journal\":{\"name\":\"Kontrol'. Diagnostika\",\"volume\":\"25 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kontrol'. Diagnostika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14489/td.2023.10.pp.050-053\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kontrol'. Diagnostika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14489/td.2023.10.pp.050-053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过识别和记录读数之间的差异来确定仪器与其他提供正确读数的控制仪器之间的误差值是一种常用方法。描述直接测量技术设备基本特性的测量装置,表征实验室测力计的测力精度。采用的测量方法是通过显示测量仪器直接确定所需值。该设备可通过更换所含模块进行重新配置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CALIBRATION OF THE PIEZOELECTRIC DYNAMOMETER KISTLER USING A MEASURING DEVICE BASED ON A SAMPLE COMPRESSION DYNAMOMETER
Establishing the error values of instruments with other control instruments that give correct readings by identifying and documenting differences between readings is a common method. A description of the measuring device for direct measurement of basic properties of technological equipment characterizing the accuracy of force measurement by a laboratory dynamometer. A measurement method is used, in which the desired value is determined directly by the displaying measuring instrument. The device is reconfigured by changing the included modules.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DIAGNOSTICS OF INTERELECTRODE GAP’S CONDITION USING VIBROACOUSTIC EMISSION APPLICATION OF ACOUSTIC EMISSION METHOD FOR DETECTING DIFFUSION INTERLAYERS IN DIFFERENT WELDED JOINTS CALIBRATION OF THE PIEZOELECTRIC DYNAMOMETER KISTLER USING A MEASURING DEVICE BASED ON A SAMPLE COMPRESSION DYNAMOMETER TOPOLOGY OF MANUFACTURING A SORPTION-CAPACITIVE HUMIDITY SENSOR BASED ON THIN FILMS OBTAINED BY MICROARC OXIDATION AND MAGNETRON SPUTTERING INVESTIGATION OF THE TEMPERATURE ERROR OF COORDINATE MEASURING MACHINES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1