{"title":"不同压实系数下丘式储罐的边坡稳定性分析","authors":"Yunsheng Ma, Zizhuo Tao, Yu Zhang, Zhenxue Liu, Shengke Wei, Fenghao Qing","doi":"10.1155/2024/6682882","DOIUrl":null,"url":null,"abstract":"Mounded storage tank is to cover the storage tank with compacted soil on the ground to avoid steam cloud explosion, ensuring the stability and safety of the storage tank. In view of the influence of large diameter and surface radian of the tank, slope stability of mounded storage tank under different compaction coefficients has become the focus of research. In this paper, a series of laboratory tests were carried out to obtain the physical and mechanical parameters of the soil samples collected from the overburden of one specific engineering project. On this basis, Plaxis2D finite element software was used to establish a numerical model of the horizontal tank with a diameter of 7.6 m and a length of 76 m and the mounded slope with a height of 16.25 m as the research object. The effects of different compaction coefficients, slope angles, and overburden thicknesses on the slope stability of the mounded storage tank are investigated. Results indicate that the slope stability coefficients increase with the increase of compaction coefficient but decrease with the increase of slope angle and overburden thickness. Under the condition of the compaction coefficient 0.75–0.95, slope angle 30°–60°, and overburden thickness 0.5–1.3 m, the sensitivity ranking on the slope stability of mounded storage tank is: compaction coefficient, slope angle, and overburden thickness. The analysis results can provide an important theoretical basis and technical support for the safety and stability evaluation of mounded horizontal tank project.","PeriodicalId":7242,"journal":{"name":"Advances in Civil Engineering","volume":"1 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Slope Stability Analysis of Mounded Storage Tank under Different Compaction Coefficients\",\"authors\":\"Yunsheng Ma, Zizhuo Tao, Yu Zhang, Zhenxue Liu, Shengke Wei, Fenghao Qing\",\"doi\":\"10.1155/2024/6682882\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mounded storage tank is to cover the storage tank with compacted soil on the ground to avoid steam cloud explosion, ensuring the stability and safety of the storage tank. In view of the influence of large diameter and surface radian of the tank, slope stability of mounded storage tank under different compaction coefficients has become the focus of research. In this paper, a series of laboratory tests were carried out to obtain the physical and mechanical parameters of the soil samples collected from the overburden of one specific engineering project. On this basis, Plaxis2D finite element software was used to establish a numerical model of the horizontal tank with a diameter of 7.6 m and a length of 76 m and the mounded slope with a height of 16.25 m as the research object. The effects of different compaction coefficients, slope angles, and overburden thicknesses on the slope stability of the mounded storage tank are investigated. Results indicate that the slope stability coefficients increase with the increase of compaction coefficient but decrease with the increase of slope angle and overburden thickness. Under the condition of the compaction coefficient 0.75–0.95, slope angle 30°–60°, and overburden thickness 0.5–1.3 m, the sensitivity ranking on the slope stability of mounded storage tank is: compaction coefficient, slope angle, and overburden thickness. The analysis results can provide an important theoretical basis and technical support for the safety and stability evaluation of mounded horizontal tank project.\",\"PeriodicalId\":7242,\"journal\":{\"name\":\"Advances in Civil Engineering\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-02-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Civil Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/6682882\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Civil Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2024/6682882","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Slope Stability Analysis of Mounded Storage Tank under Different Compaction Coefficients
Mounded storage tank is to cover the storage tank with compacted soil on the ground to avoid steam cloud explosion, ensuring the stability and safety of the storage tank. In view of the influence of large diameter and surface radian of the tank, slope stability of mounded storage tank under different compaction coefficients has become the focus of research. In this paper, a series of laboratory tests were carried out to obtain the physical and mechanical parameters of the soil samples collected from the overburden of one specific engineering project. On this basis, Plaxis2D finite element software was used to establish a numerical model of the horizontal tank with a diameter of 7.6 m and a length of 76 m and the mounded slope with a height of 16.25 m as the research object. The effects of different compaction coefficients, slope angles, and overburden thicknesses on the slope stability of the mounded storage tank are investigated. Results indicate that the slope stability coefficients increase with the increase of compaction coefficient but decrease with the increase of slope angle and overburden thickness. Under the condition of the compaction coefficient 0.75–0.95, slope angle 30°–60°, and overburden thickness 0.5–1.3 m, the sensitivity ranking on the slope stability of mounded storage tank is: compaction coefficient, slope angle, and overburden thickness. The analysis results can provide an important theoretical basis and technical support for the safety and stability evaluation of mounded horizontal tank project.
期刊介绍:
Advances in Civil Engineering publishes papers in all areas of civil engineering. The journal welcomes submissions across a range of disciplines, and publishes both theoretical and practical studies. Contributions from academia and from industry are equally encouraged.
Subject areas include (but are by no means limited to):
-Structural mechanics and engineering-
Structural design and construction management-
Structural analysis and computational mechanics-
Construction technology and implementation-
Construction materials design and engineering-
Highway and transport engineering-
Bridge and tunnel engineering-
Municipal and urban engineering-
Coastal, harbour and offshore engineering--
Geotechnical and earthquake engineering
Engineering for water, waste, energy, and environmental applications-
Hydraulic engineering and fluid mechanics-
Surveying, monitoring, and control systems in construction-
Health and safety in a civil engineering setting.
Advances in Civil Engineering also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.