通过浸入式和滴注式浇铸工艺制作可抛光、可重复使用的三电极,作为新一代三电极系统,用于电化学分析应用

IF 5.4 Q1 CHEMISTRY, ANALYTICAL Sensing and Bio-Sensing Research Pub Date : 2024-02-01 DOI:10.1016/j.sbsr.2024.100635
Mehrdad Abbasi , Ali Rasi Mahmoudi , Karim Asadpour-Zeynali
{"title":"通过浸入式和滴注式浇铸工艺制作可抛光、可重复使用的三电极,作为新一代三电极系统,用于电化学分析应用","authors":"Mehrdad Abbasi ,&nbsp;Ali Rasi Mahmoudi ,&nbsp;Karim Asadpour-Zeynali","doi":"10.1016/j.sbsr.2024.100635","DOIUrl":null,"url":null,"abstract":"<div><p>An innovative three-electrode system was developed for electrochemical analysis, aiming to overcome the limitations of conventional approaches. The system incorporates a glassy carbon rod as the working electrode, platinum wire as the counter electrode, and silver wire as the quasi-reference electrode that are positioned within an epoxy resin substrate. The advantages of this type of three-electrode system include the possibility of sample analysis in both drop mode and when immersed in the solution, low manufacturing cost, reduction of chemical consumption, no need for special maintenance protocols, no requirement for stand, absence of liquid junction potential (due to the direct contact of the reference electrode with the solution), usability for on-site analysis, and usability for non-aqueous solutions.</p><p>To check the efficiency of this electrode, cyclic voltammetry technique was used. Also, for direct comparison of PTE with conventional three-electrode system and screen-printed electrode (SPE), current density was used instead of peak current. According to the results, PTE system shows more peak current for the same surface area of the working electrode compared to other systems, which shows the high efficiency of the proposed system for electrochemical analysis. Acetaminophen (ACT) was chosen in order to investigate the ability to measure an analyte with PTE using differential pulse voltammetry (DPV). The linear range was obtained from 29.12 μM to 609.37 μM with a detection limit (LOD) 20.22 μM. Also, PTE was used to measure ACT in tablet as real sample.</p></div>","PeriodicalId":424,"journal":{"name":"Sensing and Bio-Sensing Research","volume":"43 ","pages":"Article 100635"},"PeriodicalIF":5.4000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2214180424000175/pdfft?md5=c7a40efc2b56536bbc1311380d4898e8&pid=1-s2.0-S2214180424000175-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Fabrication of a polishable and reusable triple electrode as a new generation of three-electrode systems for the electrochemical analysis applications through both immersion and drop casting-procedures\",\"authors\":\"Mehrdad Abbasi ,&nbsp;Ali Rasi Mahmoudi ,&nbsp;Karim Asadpour-Zeynali\",\"doi\":\"10.1016/j.sbsr.2024.100635\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>An innovative three-electrode system was developed for electrochemical analysis, aiming to overcome the limitations of conventional approaches. The system incorporates a glassy carbon rod as the working electrode, platinum wire as the counter electrode, and silver wire as the quasi-reference electrode that are positioned within an epoxy resin substrate. The advantages of this type of three-electrode system include the possibility of sample analysis in both drop mode and when immersed in the solution, low manufacturing cost, reduction of chemical consumption, no need for special maintenance protocols, no requirement for stand, absence of liquid junction potential (due to the direct contact of the reference electrode with the solution), usability for on-site analysis, and usability for non-aqueous solutions.</p><p>To check the efficiency of this electrode, cyclic voltammetry technique was used. Also, for direct comparison of PTE with conventional three-electrode system and screen-printed electrode (SPE), current density was used instead of peak current. According to the results, PTE system shows more peak current for the same surface area of the working electrode compared to other systems, which shows the high efficiency of the proposed system for electrochemical analysis. Acetaminophen (ACT) was chosen in order to investigate the ability to measure an analyte with PTE using differential pulse voltammetry (DPV). The linear range was obtained from 29.12 μM to 609.37 μM with a detection limit (LOD) 20.22 μM. Also, PTE was used to measure ACT in tablet as real sample.</p></div>\",\"PeriodicalId\":424,\"journal\":{\"name\":\"Sensing and Bio-Sensing Research\",\"volume\":\"43 \",\"pages\":\"Article 100635\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2214180424000175/pdfft?md5=c7a40efc2b56536bbc1311380d4898e8&pid=1-s2.0-S2214180424000175-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensing and Bio-Sensing Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214180424000175\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing and Bio-Sensing Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214180424000175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

为克服传统方法的局限性,我们开发了一种用于电化学分析的创新型三电极系统。该系统将玻璃碳棒作为工作电极,铂丝作为对电极,银丝作为准参比电极,放置在环氧树脂基底中。这种三电极系统的优点包括:可在滴液模式和浸入溶液模式下进行样品分析;制造成本低;减少化学品消耗;无需特殊维护规程;无需支架;无液交电位(由于参比电极与溶液直接接触);适用于现场分析;适用于非水溶液。此外,为了将 PTE 与传统的三电极系统和丝网印刷电极(SPE)进行直接比较,使用了电流密度而不是峰值电流。结果表明,与其他系统相比,PTE 系统在工作电极表面积相同的情况下显示出更高的峰值电流,这表明所提议的系统在电化学分析中具有很高的效率。选择对乙酰氨基酚(ACT)作为研究对象,考察 PTE 使用差分脉冲伏安法(DPV)测量分析物的能力。其线性范围为 29.12 μM 至 609.37 μM,检测限(LOD)为 20.22 μM。此外,还使用 PTE 检测了片剂中的 ACT(真实样品)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fabrication of a polishable and reusable triple electrode as a new generation of three-electrode systems for the electrochemical analysis applications through both immersion and drop casting-procedures

An innovative three-electrode system was developed for electrochemical analysis, aiming to overcome the limitations of conventional approaches. The system incorporates a glassy carbon rod as the working electrode, platinum wire as the counter electrode, and silver wire as the quasi-reference electrode that are positioned within an epoxy resin substrate. The advantages of this type of three-electrode system include the possibility of sample analysis in both drop mode and when immersed in the solution, low manufacturing cost, reduction of chemical consumption, no need for special maintenance protocols, no requirement for stand, absence of liquid junction potential (due to the direct contact of the reference electrode with the solution), usability for on-site analysis, and usability for non-aqueous solutions.

To check the efficiency of this electrode, cyclic voltammetry technique was used. Also, for direct comparison of PTE with conventional three-electrode system and screen-printed electrode (SPE), current density was used instead of peak current. According to the results, PTE system shows more peak current for the same surface area of the working electrode compared to other systems, which shows the high efficiency of the proposed system for electrochemical analysis. Acetaminophen (ACT) was chosen in order to investigate the ability to measure an analyte with PTE using differential pulse voltammetry (DPV). The linear range was obtained from 29.12 μM to 609.37 μM with a detection limit (LOD) 20.22 μM. Also, PTE was used to measure ACT in tablet as real sample.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensing and Bio-Sensing Research
Sensing and Bio-Sensing Research Engineering-Electrical and Electronic Engineering
CiteScore
10.70
自引率
3.80%
发文量
68
审稿时长
87 days
期刊介绍: Sensing and Bio-Sensing Research is an open access journal dedicated to the research, design, development, and application of bio-sensing and sensing technologies. The editors will accept research papers, reviews, field trials, and validation studies that are of significant relevance. These submissions should describe new concepts, enhance understanding of the field, or offer insights into the practical application, manufacturing, and commercialization of bio-sensing and sensing technologies. The journal covers a wide range of topics, including sensing principles and mechanisms, new materials development for transducers and recognition components, fabrication technology, and various types of sensors such as optical, electrochemical, mass-sensitive, gas, biosensors, and more. It also includes environmental, process control, and biomedical applications, signal processing, chemometrics, optoelectronic, mechanical, thermal, and magnetic sensors, as well as interface electronics. Additionally, it covers sensor systems and applications, µTAS (Micro Total Analysis Systems), development of solid-state devices for transducing physical signals, and analytical devices incorporating biological materials.
期刊最新文献
“All-on-a-Tube” POCT of Salmonella in large-volume sample Design of flexible polyimide-based serpentine EMG sensor for AI-enabled fatigue detection in construction Molecular displacement approach for the electrochemical detection of protein-bound propofol Biosensor for integrin inhibition of mammalian cell adhesion and migration using micropatterned cell culture substrate and retroreflective optical signaling Advancements in electrochemiluminescence-based sensors for ultra-sensitive pesticide residue detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1