考虑微循环功能的动脉旁路移植血液动力学模型

IF 1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Bio-medical materials and engineering Pub Date : 2024-03-05 DOI:10.3233/bme-230145
Fan He, Minru Li, Lu Hua, Tingting Guo
{"title":"考虑微循环功能的动脉旁路移植血液动力学模型","authors":"Fan He, Minru Li, Lu Hua, Tingting Guo","doi":"10.3233/bme-230145","DOIUrl":null,"url":null,"abstract":"BACKGROUND:The incidence of arterial stenosis is increasing year by year. In order to better diagnose and treat arterial stenosis, numerical simulation technology has become a popular method. OBJECTIVE:A novel model is constructed to investigate the influence of microcirculation on the hemodynamicsof artery bypass graft. METHODS:In this paper, a severely narrow artery bypass graft model is considered. The geometric shape includes a narrow artery tube and a bypass graft of the same diameter with a 45° suture angle. The fluid-structure interaction model is considered by finite element numerical calculation, and the flow is simulated with microcirculation as the outlet boundary condition. The changes of blood flow velocity, pressure and wall shear stress are analyzed. RESULTS:The results show that blood almost entirely flows into the graft tube and there is no recirculation area at the anastomosis. CONCLUSION:The artery bypass graft model considering microcirculation function could simulate the physiological characteristics of blood flow more reasonably, and it provide helps for clinicians to diagnose and treat arterial stenosis.","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":"9 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A hemodynamic model of artery bypass graft considering microcirculation function\",\"authors\":\"Fan He, Minru Li, Lu Hua, Tingting Guo\",\"doi\":\"10.3233/bme-230145\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND:The incidence of arterial stenosis is increasing year by year. In order to better diagnose and treat arterial stenosis, numerical simulation technology has become a popular method. OBJECTIVE:A novel model is constructed to investigate the influence of microcirculation on the hemodynamicsof artery bypass graft. METHODS:In this paper, a severely narrow artery bypass graft model is considered. The geometric shape includes a narrow artery tube and a bypass graft of the same diameter with a 45° suture angle. The fluid-structure interaction model is considered by finite element numerical calculation, and the flow is simulated with microcirculation as the outlet boundary condition. The changes of blood flow velocity, pressure and wall shear stress are analyzed. RESULTS:The results show that blood almost entirely flows into the graft tube and there is no recirculation area at the anastomosis. CONCLUSION:The artery bypass graft model considering microcirculation function could simulate the physiological characteristics of blood flow more reasonably, and it provide helps for clinicians to diagnose and treat arterial stenosis.\",\"PeriodicalId\":9109,\"journal\":{\"name\":\"Bio-medical materials and engineering\",\"volume\":\"9 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-03-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bio-medical materials and engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/bme-230145\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/bme-230145","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:动脉狭窄的发病率逐年上升。为了更好地诊断和治疗动脉狭窄,数值模拟技术已成为一种流行的方法。目的:建立一个新模型,研究微循环对动脉旁路移植血液动力学的影响。方法:本文考虑了一个严重狭窄的动脉旁路移植模型。该模型的几何形状包括一个狭窄的动脉管和一个直径相同、缝合角为 45°的旁路移植管。通过有限元数值计算考虑流体与结构相互作用模型,并以微循环为出口边界条件模拟流动。分析了血流速度、压力和壁剪应力的变化。结果:结果表明,血液几乎全部流入移植管,吻合处没有再循环区域。结论:考虑微循环功能的动脉旁路移植模型能更合理地模拟血流的生理特性,有助于临床医生诊断和治疗动脉狭窄。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A hemodynamic model of artery bypass graft considering microcirculation function
BACKGROUND:The incidence of arterial stenosis is increasing year by year. In order to better diagnose and treat arterial stenosis, numerical simulation technology has become a popular method. OBJECTIVE:A novel model is constructed to investigate the influence of microcirculation on the hemodynamicsof artery bypass graft. METHODS:In this paper, a severely narrow artery bypass graft model is considered. The geometric shape includes a narrow artery tube and a bypass graft of the same diameter with a 45° suture angle. The fluid-structure interaction model is considered by finite element numerical calculation, and the flow is simulated with microcirculation as the outlet boundary condition. The changes of blood flow velocity, pressure and wall shear stress are analyzed. RESULTS:The results show that blood almost entirely flows into the graft tube and there is no recirculation area at the anastomosis. CONCLUSION:The artery bypass graft model considering microcirculation function could simulate the physiological characteristics of blood flow more reasonably, and it provide helps for clinicians to diagnose and treat arterial stenosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bio-medical materials and engineering
Bio-medical materials and engineering 工程技术-材料科学:生物材料
CiteScore
1.80
自引率
0.00%
发文量
73
审稿时长
6 months
期刊介绍: The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.
期刊最新文献
Extract from Falcaria vulgaris loaded with exosomes for the treatment of hypertension in pregnant mice: In vitro and In vivo investigations. Acupuncture navigation method integrated with augmented reality. Assessment of decellularization strategy and biocompatibility testing of full-thickness abdominal wall to produce a tissue-engineered graft. Effect of bioceramic inclusions on gel-cast aliphatic polymer membranes for bone tissue engineering applications: An in vitro study. Promotion of maturation in CDM3-induced embryonic stem cell-derived cardiomyocytes by palmitic acid.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1