{"title":"基于人工智能监测平台的患者实时质量控制在唐氏综合征血清筛查质量风险持续监测中的应用。","authors":"Xuran Yang,&nbsp;Qianlan Chen,&nbsp;Zhifeng Pan,&nbsp;Jingmao Cheng,&nbsp;Wenting Zheng,&nbsp;Yingliang Liang,&nbsp;Hui Chen,&nbsp;Guanghui Chen,&nbsp;Wandang Wang","doi":"10.1002/jcla.25019","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Patient-based real-time quality control (PBRTQC) has gained attention because of its potential to continuously monitor the analytical quality in situations wherein internal quality control (IQC) is less effective. Therefore, we tried to investigate the application of PBRTQC method based on an artificial intelligence monitoring (AI-MA) platform in quality risk monitoring of Down syndrome (DS) serum screening.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The DS serum screening item determination data and relative IQC data from January 4 to September 7 in 2021 were collected. Then, PBRTQC exponentially weighted moving average (EWMA) and moving average (MA) procedures were built and optimized in the AI-MA platform. The efficiency of the EWMA and MA procedures with intelligent and traditional control rules were compared. Next, the optimal EWMA procedures that contributed to the quality assurance of serum screening were run and generated early warning cases were investigated.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Optimal EWMA and MA procedures on the AI-MA platform were built. Comparison results showed the EWMA procedure with intelligent QC rules but not traditional quality rules contained the best efficiency. Based on the AI-MA platform, two early warning cases were generated by using the optimal EWMA procedure, which finally found were caused by instrument failure. Moreover, the EWMA procedure could truly reflect the detection accuracy and quality in situations wherein traditional IQC products were unstable or concentrations were inappropriate.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The EWMA procedure built by the AI-MA platform could be a good complementary control tool for the DS serum screening by truly and timely reflecting the detection quality risks.</p>\n </section>\n </div>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jcla.25019","citationCount":"0","resultStr":"{\"title\":\"Application of Patient-Based Real-Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening\",\"authors\":\"Xuran Yang,&nbsp;Qianlan Chen,&nbsp;Zhifeng Pan,&nbsp;Jingmao Cheng,&nbsp;Wenting Zheng,&nbsp;Yingliang Liang,&nbsp;Hui Chen,&nbsp;Guanghui Chen,&nbsp;Wandang Wang\",\"doi\":\"10.1002/jcla.25019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>Patient-based real-time quality control (PBRTQC) has gained attention because of its potential to continuously monitor the analytical quality in situations wherein internal quality control (IQC) is less effective. Therefore, we tried to investigate the application of PBRTQC method based on an artificial intelligence monitoring (AI-MA) platform in quality risk monitoring of Down syndrome (DS) serum screening.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The DS serum screening item determination data and relative IQC data from January 4 to September 7 in 2021 were collected. Then, PBRTQC exponentially weighted moving average (EWMA) and moving average (MA) procedures were built and optimized in the AI-MA platform. The efficiency of the EWMA and MA procedures with intelligent and traditional control rules were compared. Next, the optimal EWMA procedures that contributed to the quality assurance of serum screening were run and generated early warning cases were investigated.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Optimal EWMA and MA procedures on the AI-MA platform were built. Comparison results showed the EWMA procedure with intelligent QC rules but not traditional quality rules contained the best efficiency. Based on the AI-MA platform, two early warning cases were generated by using the optimal EWMA procedure, which finally found were caused by instrument failure. Moreover, the EWMA procedure could truly reflect the detection accuracy and quality in situations wherein traditional IQC products were unstable or concentrations were inappropriate.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The EWMA procedure built by the AI-MA platform could be a good complementary control tool for the DS serum screening by truly and timely reflecting the detection quality risks.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15509,\"journal\":{\"name\":\"Journal of Clinical Laboratory Analysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-03-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jcla.25019\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Laboratory Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jcla.25019\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jcla.25019","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:基于患者的实时质量控制(PBRTQC)因其在内部质量控制(IQC)效果不佳的情况下持续监测分析质量的潜力而备受关注。因此,我们尝试研究基于人工智能监测(AI-MA)平台的 PBRTQC 方法在唐氏综合征(DS)血清筛查质量风险监测中的应用:方法:收集2021年1月4日至9月7日的DS血清筛查项目测定数据和相对IQC数据。然后,在 AI-MA 平台上构建并优化了 PBRTQC 指数加权移动平均(EWMA)和移动平均(MA)程序。比较了采用智能控制规则和传统控制规则的 EWMA 和 MA 程序的效率。接下来,运行了有助于保证血清筛查质量的最优 EWMA 程序,并对产生的预警案例进行了调查:结果:在 AI-MA 平台上建立了最优 EWMA 和 MA 程序。比较结果表明,采用智能质量控制规则而非传统质量规则的 EWMA 程序效率最高。基于 AI-MA 平台,使用最优 EWMA 程序生成了两个预警案例,最终发现这两个案例是由仪器故障引起的。此外,在传统 IQC 产品不稳定或浓度不合适的情况下,EWMA 程序能真实反映检测精度和质量:由 AI-MA 平台构建的 EWMA 程序可以真实、及时地反映 DS 血清筛查的检测质量风险,是一种很好的辅助控制工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of Patient-Based Real-Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening

Background

Patient-based real-time quality control (PBRTQC) has gained attention because of its potential to continuously monitor the analytical quality in situations wherein internal quality control (IQC) is less effective. Therefore, we tried to investigate the application of PBRTQC method based on an artificial intelligence monitoring (AI-MA) platform in quality risk monitoring of Down syndrome (DS) serum screening.

Methods

The DS serum screening item determination data and relative IQC data from January 4 to September 7 in 2021 were collected. Then, PBRTQC exponentially weighted moving average (EWMA) and moving average (MA) procedures were built and optimized in the AI-MA platform. The efficiency of the EWMA and MA procedures with intelligent and traditional control rules were compared. Next, the optimal EWMA procedures that contributed to the quality assurance of serum screening were run and generated early warning cases were investigated.

Results

Optimal EWMA and MA procedures on the AI-MA platform were built. Comparison results showed the EWMA procedure with intelligent QC rules but not traditional quality rules contained the best efficiency. Based on the AI-MA platform, two early warning cases were generated by using the optimal EWMA procedure, which finally found were caused by instrument failure. Moreover, the EWMA procedure could truly reflect the detection accuracy and quality in situations wherein traditional IQC products were unstable or concentrations were inappropriate.

Conclusions

The EWMA procedure built by the AI-MA platform could be a good complementary control tool for the DS serum screening by truly and timely reflecting the detection quality risks.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Laboratory Analysis
Journal of Clinical Laboratory Analysis 医学-医学实验技术
CiteScore
5.60
自引率
7.40%
发文量
584
审稿时长
6-12 weeks
期刊介绍: Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.
期刊最新文献
Evaluating Bacterial Viability in Faecal Microbiota Transplantation: A Comparative Analysis of In Vitro Cultivation and Membrane Integrity Methods. Effects of Blood Collection Tubes on the Quantification of Catecholamines and Their O-Methylated Metabolites by Liquid Chromatography Coupled With Tandem Mass Spectrometry. Diagnostic Performance of CLEIA Versus FEIA for KL-6 Peripheral and Alveolar Concentrations in Fibrotic Interstitial Lung Diseases: A Multicentre Study. Application of Different Staining Methods in the Diagnosis of Pigment-Rich Melanoma. Clinical Utility of Circulating Tumor DNA for Detecting Lung Cancer Mutations by Targeted Next-Generation Sequencing With Insufficient Tumor Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1