{"title":"关键对比 CCAUV.W-K2:水听器校准功能","authors":"A. Isaev, A. Matveev, S. V. Strelov, N. G. Shcherblyuk","doi":"10.32446/0368-1025it.2024-1-67-72","DOIUrl":null,"url":null,"abstract":"The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.","PeriodicalId":14651,"journal":{"name":"Izmeritel`naya Tekhnika","volume":"124 S175","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Key comparison CCAUV.W-K2: features of hydrophone calibration\",\"authors\":\"A. Isaev, A. Matveev, S. V. Strelov, N. G. Shcherblyuk\",\"doi\":\"10.32446/0368-1025it.2024-1-67-72\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.\",\"PeriodicalId\":14651,\"journal\":{\"name\":\"Izmeritel`naya Tekhnika\",\"volume\":\"124 S175\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Izmeritel`naya Tekhnika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32446/0368-1025it.2024-1-67-72\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Izmeritel`naya Tekhnika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32446/0368-1025it.2024-1-67-72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

关键比对结果是确认新开发测量方法正确性和准确性的最有说服力的客观指标。本文介绍了由国际计量委员会声学、超声波和振动咨询委员会组织的第二次水中声压单位 CCAUV.W-K2 国家标准关键比对的比对结果和测量方法。这次比对的一个特点是,与第一次关键比对 CCAUV.W-K1 相比,校准范围向低频区扩展了两个八度。CCAUV.W-K2 的比对结果被认为是成功的。参加比对的重要科学成果是:确认了 VNIIFTRI 开发的水听器自由声场校准方法的正确性(在声反射水箱的超低频率和水箱的噪声混响声场中),以及在辐射各种类型信号时校准结果的等效性:鸣声、噪声和音爆。在进行控制校准的过程中,试验实验室发现对比参考水听器的稳定性有问题。在比较参与者获得的结果时,60-100 千赫频率范围内的结果差异有所增加,而这一频率范围被认为是问题最少的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Key comparison CCAUV.W-K2: features of hydrophone calibration
The results of key comparison are the most convincing and objective indicator of confirmation of the correctness and accuracy of the newly developed measurement method. The results of comparison and measurement methods applied at the second key comparison of national standards of the unit of sound pressure in water CCAUV.W-K2, organized by the Consultative Committee for Acoustics, Ultrasound and Vibration of the International Committee for Weights and Measures, are described. A feature of the comparison is that the calibration range has been expanded into the low frequency region by two octaves compared to the first key comparison CCAUV.W-K1. The results of the CCAUV.W-K2 comparison were considered successful. Important scientific results of participation in the comparison were confirmation of: the correctness of the hydrophone free-field calibration methods developed at VNIIFTRI (at ultra-low frequencies for a sound-reflecting water tank and in the noise reverberant sound field of the water tank), the equivalence of the calibration results when radiating signals of various types: chirp, noise and ton-burst. In the process of performing control calibrations, the pilot laboratory discovered violations of the stability of the reference hydrophone of comparison. When comparing the results obtained by participants, there was an increase in the discrepancy between the results in the frequency range 60–100 kHz, which is considered the least problematic.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
International comparisons in the field of measurement of specific adsorption of gases and specific surface area of solids: the optimal amount to ensure calibration and measurement capabilities Experimental installation of a reference source of low currents for calibration of electrometers Development of state information systems in the field of metrology: main tasks Effect of surfactants on the degree of polydispersity of a suspension of polystyrene latex spheres Scientific equipment for the “Sun-Terahertz” space experiment: study of the temperature effect of the Golay cell
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1