后续双边关键对比研究--有机溶剂校准溶液--乙腈(ACN)中黄曲霉毒素 B1(AfB1)的重量制备和数值分配

IF 2.1 3区 工程技术 Q2 INSTRUMENTS & INSTRUMENTATION Metrologia Pub Date : 2024-03-13 DOI:10.1088/0026-1394/61/1a/08004
R D Josephs, M Bedu, A Daireaux, Xiuqin Li, Xiaomin Li, Z Guo, Xianjiang Li, T Choteau, G Martos, S Westwood, R I Wielgosz, H Li, H Klich, R Torkhani, W Bellazreg, S Chaieb, H Sallemi, K Alimi
{"title":"后续双边关键对比研究--有机溶剂校准溶液--乙腈(ACN)中黄曲霉毒素 B1(AfB1)的重量制备和数值分配","authors":"R D Josephs, M Bedu, A Daireaux, Xiuqin Li, Xiaomin Li, Z Guo, Xianjiang Li, T Choteau, G Martos, S Westwood, R I Wielgosz, H Li, H Klich, R Torkhani, W Bellazreg, S Chaieb, H Sallemi, K Alimi","doi":"10.1088/0026-1394/61/1a/08004","DOIUrl":null,"url":null,"abstract":"<title>Main text</title>The original CCQM-K154.b comparison was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM) on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA) and/or have participated in the BIPM's Mycotoxin Metrology Capacity Building and Knowledge Transfer (MMCBKT) project as part of its \"Metrology for Safe Food and Feed in Developing Economies\" Capacity Building Programme.Gravimetrically-prepared solutions having an assigned mass fraction of specified organic analytes are routinely used to calibrate measurement processes for the quantification of the same analytes in matrix samples. Appropriate assignments of the property value and associated uncertainty of calibration solutions thus underpin the traceability of routine analysis and are critical for accurate measurements. Evidence of successful participation in relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes and designated institutes. In total, eleven NMIs/DIs participated in the Track C, Model II, Key Comparison CCQM-K154.b [Gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)] for emerging areas of global interest and innovation. Participants were requested to gravimetrically prepare calibration solutions and value assign the mass fractions, expressed in mg/kg, of aflatoxin B1 (AfB1) in the acetonitrile (ACN) solution. Study samples, with assigned values and associated uncertainties were prepared by the comparison participants and sent to the coordinating laboratory for comparison. The Key Comparison Reference Values (KCRVs), calculated form values measured by the coordinating laboratory based on calibrations obtained from independent gravimetrically prepared calibrant solutions, agreed with participants reported values, within their stated uncertainties.AfB1 was selected to be representative of polar aflatoxins. Aflatoxins are a class of mycotoxins generally produced by fungi of the genus Aspergillus. It was anticipated to provide a challenge representative for the gravimetrical preparation and value assignment of calibration solutions in the mass fraction range of 2 mg/kg to 50 mg/kg of mycotoxins with broadly similar structural characteristics.In the original study CCQM-K154.b, nine participants of the MMCBKT programme were provided with a stock solution having a known AfB1 mass fraction and expanded uncertainty to use to gravimetrically prepare and value assign a calibration solution. Three NMIs/DIs also participated using their own calibration solutions. The use of in-house solutions required anadditional capacity to undertake a fit-for-purpose purity assessment. NIM was the only NMI participating using both the MMCBKT based and their own in-house assigned solutions in order to connect the two different groups.It was decided to propose separate KCRVs for each of the two ampoules provided by the participating NMIs/DIs based on the AfB1 mass fraction. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibrations solutions and to assess the AfB1 mass fraction.The majority of the AfB1 mass fraction KCRVs (wKCRV) for CCQM-K154.b spanned a mass fraction range of 2.02 mg/kg to 31.57 mg/kg. The relative expanded uncertainties U(wKCRV) ranged from 0.69 % to 2.93 %. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments in CCQM-K154.b indicated that there was an excellent agreement of results. Solely, the AfB1 mass fraction assignments of the INRAP (Institut National de Recherche et d'Analyse Physico-Chimique, Tunisia) did not agree with the KCRVs. It was found that the samples were altered as a result of an acid contamination.The INRAP has produced a new batch of AfB1 calibration solution using the AfB1 stock solution originally provided to MMCBKT participants to be able to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibrations solutions and to assess the AfB1 mass fraction. The BIPM organized the present subsequent bilateral comparison CCQM-K154.b.1 to assess the new batch of AfB1 calibration solution of the INRAP. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments indicated that there is an excellent agreement of the INRAP results for CCQM-K154.b.1.To reach the main text of this paper, click on <ext-link xlink:href=\"https://www.bipm.org/documents/d/guest/ccqm-k154-b-1-1\" xlink:type=\"simple\">Final Report</ext-link>. Note that this text is that which appears in Appendix B of the BIPM key comparison database <ext-link xlink:href=\"https://www.bipm.org/kcdb/\" xlink:type=\"simple\">https://www.bipm.org/kcdb/</ext-link>.The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":"31 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Subsequent bilateral key comparison study - organic solvent calibration solution - gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)\",\"authors\":\"R D Josephs, M Bedu, A Daireaux, Xiuqin Li, Xiaomin Li, Z Guo, Xianjiang Li, T Choteau, G Martos, S Westwood, R I Wielgosz, H Li, H Klich, R Torkhani, W Bellazreg, S Chaieb, H Sallemi, K Alimi\",\"doi\":\"10.1088/0026-1394/61/1a/08004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<title>Main text</title>The original CCQM-K154.b comparison was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM) on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA) and/or have participated in the BIPM's Mycotoxin Metrology Capacity Building and Knowledge Transfer (MMCBKT) project as part of its \\\"Metrology for Safe Food and Feed in Developing Economies\\\" Capacity Building Programme.Gravimetrically-prepared solutions having an assigned mass fraction of specified organic analytes are routinely used to calibrate measurement processes for the quantification of the same analytes in matrix samples. Appropriate assignments of the property value and associated uncertainty of calibration solutions thus underpin the traceability of routine analysis and are critical for accurate measurements. Evidence of successful participation in relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes and designated institutes. In total, eleven NMIs/DIs participated in the Track C, Model II, Key Comparison CCQM-K154.b [Gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)] for emerging areas of global interest and innovation. Participants were requested to gravimetrically prepare calibration solutions and value assign the mass fractions, expressed in mg/kg, of aflatoxin B1 (AfB1) in the acetonitrile (ACN) solution. Study samples, with assigned values and associated uncertainties were prepared by the comparison participants and sent to the coordinating laboratory for comparison. The Key Comparison Reference Values (KCRVs), calculated form values measured by the coordinating laboratory based on calibrations obtained from independent gravimetrically prepared calibrant solutions, agreed with participants reported values, within their stated uncertainties.AfB1 was selected to be representative of polar aflatoxins. Aflatoxins are a class of mycotoxins generally produced by fungi of the genus Aspergillus. It was anticipated to provide a challenge representative for the gravimetrical preparation and value assignment of calibration solutions in the mass fraction range of 2 mg/kg to 50 mg/kg of mycotoxins with broadly similar structural characteristics.In the original study CCQM-K154.b, nine participants of the MMCBKT programme were provided with a stock solution having a known AfB1 mass fraction and expanded uncertainty to use to gravimetrically prepare and value assign a calibration solution. Three NMIs/DIs also participated using their own calibration solutions. The use of in-house solutions required anadditional capacity to undertake a fit-for-purpose purity assessment. NIM was the only NMI participating using both the MMCBKT based and their own in-house assigned solutions in order to connect the two different groups.It was decided to propose separate KCRVs for each of the two ampoules provided by the participating NMIs/DIs based on the AfB1 mass fraction. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibrations solutions and to assess the AfB1 mass fraction.The majority of the AfB1 mass fraction KCRVs (wKCRV) for CCQM-K154.b spanned a mass fraction range of 2.02 mg/kg to 31.57 mg/kg. The relative expanded uncertainties U(wKCRV) ranged from 0.69 % to 2.93 %. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments in CCQM-K154.b indicated that there was an excellent agreement of results. Solely, the AfB1 mass fraction assignments of the INRAP (Institut National de Recherche et d'Analyse Physico-Chimique, Tunisia) did not agree with the KCRVs. It was found that the samples were altered as a result of an acid contamination.The INRAP has produced a new batch of AfB1 calibration solution using the AfB1 stock solution originally provided to MMCBKT participants to be able to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibrations solutions and to assess the AfB1 mass fraction. The BIPM organized the present subsequent bilateral comparison CCQM-K154.b.1 to assess the new batch of AfB1 calibration solution of the INRAP. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments indicated that there is an excellent agreement of the INRAP results for CCQM-K154.b.1.To reach the main text of this paper, click on <ext-link xlink:href=\\\"https://www.bipm.org/documents/d/guest/ccqm-k154-b-1-1\\\" xlink:type=\\\"simple\\\">Final Report</ext-link>. Note that this text is that which appears in Appendix B of the BIPM key comparison database <ext-link xlink:href=\\\"https://www.bipm.org/kcdb/\\\" xlink:type=\\\"simple\\\">https://www.bipm.org/kcdb/</ext-link>.The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).\",\"PeriodicalId\":18444,\"journal\":{\"name\":\"Metrologia\",\"volume\":\"31 1\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrologia\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/0026-1394/61/1a/08004\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/0026-1394/61/1a/08004","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

正文最初的 CCQM-K154.b 比对由国际计量局(BIPM)和中国计量科学研究院(NIM)代表材料定量咨询委员会(CCQM)有机分析工作组(OAWG)协调,对象是根据 "国际计量委员会互认安排"(CIPM MRA)提供有机分析测量服务和/或参加过CCQM-K154.B比对的国家计量机构(NMI)和指定机构(DIs)。根据 "国际计量委员会互认安排"(CIPM MRA)提供有机分析计量服务和/或参加了 BIPM 的霉菌毒素计量能力建设和知识转让 (MMCBKT) 项目,该项目是其 "发展中经济体安全食品和饲料计量 "能力建设计划的一部分。用重力法制备的溶液中含有指定质量分数的有机分析物,通常用于校准测量过程,对基质样品中的相同分析物进行定量。因此,对校准溶液的属性值和相关不确定性进行适当分配,是例行分析可追溯性的基础,也是准确测量的关键。国家计量机构和指定机构需要提供成功参与相关国际比对的证据,以证明其校准和测量能力声明(CMC)。共有 11 个国家计量院/指定计量院参加了 C 轨道 II 型关键比对 CCQM-K154.b[乙腈(ACN)中黄曲霉毒素 B1(AfB1)的重量制备和赋值],以了解全球关注的新领域和创新。要求参加者用重量法配制校准溶液,并对乙腈(ACN)溶液中黄曲霉毒素 B1(AfB1)的质量分数进行赋值(以毫克/千克表示)。参 与 比 对 的 研 究 人 员 会 制 备 标 定 值 及 相 关 不 确 定 值 的 研 究 样 本 , 并 送 交 协 调 实 验 室 进 行 比 对 。关键比较参考值(KCRVs)是协调实验室根据从独立的重力校准溶液中获得的校准值计算得出的,与参与者报告的值一致,且不超出其所述的不确定性范围。黄曲霉毒素是一类霉菌毒素,通常由曲霉属真菌产生。在最初的 CCQM-K154.b 研究中,九名参与 MMCBKT 计划的人员获得了已知 AfB1 质量分数和扩大不确定度的储备溶液,用于以重力法配制校准溶液并进行赋值。三个国家监测机构/国际数据中心也使用自己的校准溶液参与了该计划。使用内部溶液需要额外的能力来进行适合目的的纯度评估。NIM 是唯一一个同时使用基于 MMCBKT 的溶液和自己的内部指定溶液的 NMI,以便将两个不同的小组联系起来。这使参与者能够展示其实施用于重力制备校准溶液和评估 AfB1 质量分数的方法的有效性。CCQM-K154.b 的大多数 AfB1 质量分数 KCRV(wKCRV)的质量分数范围为 2.02 mg/kg 至 31.57 mg/kg。相对扩展不确定度 U(wKCRV) 在 0.69 % 至 2.93 % 之间。对CCQM-K154.b中AfB1质量分数分配的等值度图进行检查后发现,结果非常一致。只有 INRAP(Institut National de Recherche et d'Analyse Physico-Chimique, Tunisia)的 AfB1 质量分数分配与 KCRVs 不一致。INRAP 使用最初提供给 MMCBKT 参与者的 AfB1 储存溶液,生产了一批新的 AfB1 校准溶液,以便能够证明他们采用重力制备校准溶液和评估 AfB1 质量分数的方法的有效性。随后,BIPM 组织了 CCQM-K154.b.1 双边比对,以评估 INRAP 的新一批 AfB1 校准溶液。对 AfB1 质量分数分配的等效度图的检查表明,INRAP 对 CCQM-K154.b.1 的结果非常一致。请注意,本文是 BIPM 关键比对数据库 https://www.bipm.org/kcdb/ 附录 B 中的文本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Subsequent bilateral key comparison study - organic solvent calibration solution - gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)
Main textThe original CCQM-K154.b comparison was coordinated by the Bureau International des Poids et Mesures (BIPM) and the Chinese National Institute of Metrology (NIM) on behalf of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) for National Measurement Institutes (NMIs) and Designated Institutes (DIs) which provide measurement services in organic analysis under the 'Comité International des Poids et Mesures' Mutual Recognition Arrangement (CIPM MRA) and/or have participated in the BIPM's Mycotoxin Metrology Capacity Building and Knowledge Transfer (MMCBKT) project as part of its "Metrology for Safe Food and Feed in Developing Economies" Capacity Building Programme.Gravimetrically-prepared solutions having an assigned mass fraction of specified organic analytes are routinely used to calibrate measurement processes for the quantification of the same analytes in matrix samples. Appropriate assignments of the property value and associated uncertainty of calibration solutions thus underpin the traceability of routine analysis and are critical for accurate measurements. Evidence of successful participation in relevant international comparisons is needed to document calibration and measurement capability claims (CMCs) made by national metrology institutes and designated institutes. In total, eleven NMIs/DIs participated in the Track C, Model II, Key Comparison CCQM-K154.b [Gravimetric preparation and value assignment of aflatoxin B1 (AfB1) in acetonitrile (ACN)] for emerging areas of global interest and innovation. Participants were requested to gravimetrically prepare calibration solutions and value assign the mass fractions, expressed in mg/kg, of aflatoxin B1 (AfB1) in the acetonitrile (ACN) solution. Study samples, with assigned values and associated uncertainties were prepared by the comparison participants and sent to the coordinating laboratory for comparison. The Key Comparison Reference Values (KCRVs), calculated form values measured by the coordinating laboratory based on calibrations obtained from independent gravimetrically prepared calibrant solutions, agreed with participants reported values, within their stated uncertainties.AfB1 was selected to be representative of polar aflatoxins. Aflatoxins are a class of mycotoxins generally produced by fungi of the genus Aspergillus. It was anticipated to provide a challenge representative for the gravimetrical preparation and value assignment of calibration solutions in the mass fraction range of 2 mg/kg to 50 mg/kg of mycotoxins with broadly similar structural characteristics.In the original study CCQM-K154.b, nine participants of the MMCBKT programme were provided with a stock solution having a known AfB1 mass fraction and expanded uncertainty to use to gravimetrically prepare and value assign a calibration solution. Three NMIs/DIs also participated using their own calibration solutions. The use of in-house solutions required anadditional capacity to undertake a fit-for-purpose purity assessment. NIM was the only NMI participating using both the MMCBKT based and their own in-house assigned solutions in order to connect the two different groups.It was decided to propose separate KCRVs for each of the two ampoules provided by the participating NMIs/DIs based on the AfB1 mass fraction. This allowed participants to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibrations solutions and to assess the AfB1 mass fraction.The majority of the AfB1 mass fraction KCRVs (wKCRV) for CCQM-K154.b spanned a mass fraction range of 2.02 mg/kg to 31.57 mg/kg. The relative expanded uncertainties U(wKCRV) ranged from 0.69 % to 2.93 %. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments in CCQM-K154.b indicated that there was an excellent agreement of results. Solely, the AfB1 mass fraction assignments of the INRAP (Institut National de Recherche et d'Analyse Physico-Chimique, Tunisia) did not agree with the KCRVs. It was found that the samples were altered as a result of an acid contamination.The INRAP has produced a new batch of AfB1 calibration solution using the AfB1 stock solution originally provided to MMCBKT participants to be able to demonstrate the efficacy of their implementation of the approaches used to gravimetrically prepare calibrations solutions and to assess the AfB1 mass fraction. The BIPM organized the present subsequent bilateral comparison CCQM-K154.b.1 to assess the new batch of AfB1 calibration solution of the INRAP. Inspection of the degree of equivalence plots for the AfB1 mass fraction assignments indicated that there is an excellent agreement of the INRAP results for CCQM-K154.b.1.To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metrologia
Metrologia 工程技术-物理:应用
CiteScore
2.80
自引率
25.00%
发文量
137
审稿时长
12 months
期刊介绍: Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them. The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics. In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.
期刊最新文献
Conversion of a piston-cylinder dimensional dataset to the effective area of a mechanical pressure generator. Evaluating the structural and predictive validity of a derivational morphology task with struggling adult readers. A robust time scale for space applications using the student’s t-distribution A digital four-arm bridge for the comparison of resistance with capacitance Traceable characterisation of fibre-coupled single-photon detectors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1