Qiang Sun, Shoufeng Zhang, Ke Liu, Xinyi Wu, Guowei Zhang, Bei Cheng
{"title":"不同剪力跨度和轴向压缩比下隔热单面复合剪力墙抗震性能的实验研究","authors":"Qiang Sun, Shoufeng Zhang, Ke Liu, Xinyi Wu, Guowei Zhang, Bei Cheng","doi":"10.1155/2024/8818666","DOIUrl":null,"url":null,"abstract":"The new insulated single-sided composite shear wall (NISCSW) composition involves setting a precast wall panel on one side and an insulation panel on the other side, with a middle cavity for casting concrete. To investigate the seismic performance of NISCSW under different shear spans and axial compression ratios, eight specimens are made, including six composite and two cast-in-place walls. The shear span ratio is controlled at 1.2 and 1.9, and the axial compression ratio is controlled at 0.1, 0.3, and 0.4. The specimens are subjected to quasistatic tests to analyze failure modes, hysteresis characteristics, stiffness degradation, displacement ductility, and energy dissipation capacity and to compare the seismic performance of the composite and cast-in-place walls. Results show that for each composite specimen, under the same axial compression ratio, the large shear span ratio specimen has a lower ultimate bearing capacity and faster stiffness degradation but better ductility and postyield energy dissipation capacity. Under the same shear span ratio, the high axial compression ratio specimen had a higher ultimate bearing capacity, slightly worse ductility, and similar stiffness degradation and energy dissipation capacity compared to other specimens. Compared with the cast-in-place specimen with the same axial compression ratio, the composite specimen failure mode and hysteresis characteristics are similar, and the ductility and energy dissipation capacity are comparable to the cast-in-place shear wall specimen, indicating that NISCSW has similar seismic performance to the cast-in-place shear wall under conditions of a large shear span ratio and high axial compression ratio. Based on the test results, the program ABAQUS is used to simulate the specimens. Compared with the test results, the simulated specimen failure mode is consistent with the test results, and the hysteresis and skeleton curves are consistent with the test curve, indicating that the model is correct, reliable, and can be verified with test results.","PeriodicalId":7242,"journal":{"name":"Advances in Civil Engineering","volume":"84 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Study on the Seismic Performance of Insulated Single-Sided Composite Shear Walls under Different Shear Spans and Axial Compression Ratios\",\"authors\":\"Qiang Sun, Shoufeng Zhang, Ke Liu, Xinyi Wu, Guowei Zhang, Bei Cheng\",\"doi\":\"10.1155/2024/8818666\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The new insulated single-sided composite shear wall (NISCSW) composition involves setting a precast wall panel on one side and an insulation panel on the other side, with a middle cavity for casting concrete. To investigate the seismic performance of NISCSW under different shear spans and axial compression ratios, eight specimens are made, including six composite and two cast-in-place walls. The shear span ratio is controlled at 1.2 and 1.9, and the axial compression ratio is controlled at 0.1, 0.3, and 0.4. The specimens are subjected to quasistatic tests to analyze failure modes, hysteresis characteristics, stiffness degradation, displacement ductility, and energy dissipation capacity and to compare the seismic performance of the composite and cast-in-place walls. Results show that for each composite specimen, under the same axial compression ratio, the large shear span ratio specimen has a lower ultimate bearing capacity and faster stiffness degradation but better ductility and postyield energy dissipation capacity. Under the same shear span ratio, the high axial compression ratio specimen had a higher ultimate bearing capacity, slightly worse ductility, and similar stiffness degradation and energy dissipation capacity compared to other specimens. Compared with the cast-in-place specimen with the same axial compression ratio, the composite specimen failure mode and hysteresis characteristics are similar, and the ductility and energy dissipation capacity are comparable to the cast-in-place shear wall specimen, indicating that NISCSW has similar seismic performance to the cast-in-place shear wall under conditions of a large shear span ratio and high axial compression ratio. Based on the test results, the program ABAQUS is used to simulate the specimens. Compared with the test results, the simulated specimen failure mode is consistent with the test results, and the hysteresis and skeleton curves are consistent with the test curve, indicating that the model is correct, reliable, and can be verified with test results.\",\"PeriodicalId\":7242,\"journal\":{\"name\":\"Advances in Civil Engineering\",\"volume\":\"84 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-05-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Civil Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/8818666\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Civil Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1155/2024/8818666","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Experimental Study on the Seismic Performance of Insulated Single-Sided Composite Shear Walls under Different Shear Spans and Axial Compression Ratios
The new insulated single-sided composite shear wall (NISCSW) composition involves setting a precast wall panel on one side and an insulation panel on the other side, with a middle cavity for casting concrete. To investigate the seismic performance of NISCSW under different shear spans and axial compression ratios, eight specimens are made, including six composite and two cast-in-place walls. The shear span ratio is controlled at 1.2 and 1.9, and the axial compression ratio is controlled at 0.1, 0.3, and 0.4. The specimens are subjected to quasistatic tests to analyze failure modes, hysteresis characteristics, stiffness degradation, displacement ductility, and energy dissipation capacity and to compare the seismic performance of the composite and cast-in-place walls. Results show that for each composite specimen, under the same axial compression ratio, the large shear span ratio specimen has a lower ultimate bearing capacity and faster stiffness degradation but better ductility and postyield energy dissipation capacity. Under the same shear span ratio, the high axial compression ratio specimen had a higher ultimate bearing capacity, slightly worse ductility, and similar stiffness degradation and energy dissipation capacity compared to other specimens. Compared with the cast-in-place specimen with the same axial compression ratio, the composite specimen failure mode and hysteresis characteristics are similar, and the ductility and energy dissipation capacity are comparable to the cast-in-place shear wall specimen, indicating that NISCSW has similar seismic performance to the cast-in-place shear wall under conditions of a large shear span ratio and high axial compression ratio. Based on the test results, the program ABAQUS is used to simulate the specimens. Compared with the test results, the simulated specimen failure mode is consistent with the test results, and the hysteresis and skeleton curves are consistent with the test curve, indicating that the model is correct, reliable, and can be verified with test results.
期刊介绍:
Advances in Civil Engineering publishes papers in all areas of civil engineering. The journal welcomes submissions across a range of disciplines, and publishes both theoretical and practical studies. Contributions from academia and from industry are equally encouraged.
Subject areas include (but are by no means limited to):
-Structural mechanics and engineering-
Structural design and construction management-
Structural analysis and computational mechanics-
Construction technology and implementation-
Construction materials design and engineering-
Highway and transport engineering-
Bridge and tunnel engineering-
Municipal and urban engineering-
Coastal, harbour and offshore engineering--
Geotechnical and earthquake engineering
Engineering for water, waste, energy, and environmental applications-
Hydraulic engineering and fluid mechanics-
Surveying, monitoring, and control systems in construction-
Health and safety in a civil engineering setting.
Advances in Civil Engineering also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.