在空间受限环境中通过改变聚焦-探测器-距离为基于机器人的 X 射线断层扫描选择可行轨迹

IF 2.6 3区 材料科学 Q2 MATERIALS SCIENCE, CHARACTERIZATION & TESTING Journal of Nondestructive Evaluation Pub Date : 2024-05-17 DOI:10.1007/s10921-024-01075-8
Maximilian Linde, Wolfram Wiest, Anna Trauth, Markus G. R. Sause
{"title":"在空间受限环境中通过改变聚焦-探测器-距离为基于机器人的 X 射线断层扫描选择可行轨迹","authors":"Maximilian Linde,&nbsp;Wolfram Wiest,&nbsp;Anna Trauth,&nbsp;Markus G. R. Sause","doi":"10.1007/s10921-024-01075-8","DOIUrl":null,"url":null,"abstract":"<div><p>Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.</p></div>","PeriodicalId":655,"journal":{"name":"Journal of Nondestructive Evaluation","volume":"43 2","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10921-024-01075-8.pdf","citationCount":"0","resultStr":"{\"title\":\"Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments\",\"authors\":\"Maximilian Linde,&nbsp;Wolfram Wiest,&nbsp;Anna Trauth,&nbsp;Markus G. R. Sause\",\"doi\":\"10.1007/s10921-024-01075-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.</p></div>\",\"PeriodicalId\":655,\"journal\":{\"name\":\"Journal of Nondestructive Evaluation\",\"volume\":\"43 2\",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s10921-024-01075-8.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nondestructive Evaluation\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10921-024-01075-8\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nondestructive Evaluation","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s10921-024-01075-8","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

摘要

计算机断层扫描已发展成为汽车行业无损检测的重要工具。应用基于机器人的计算机断层扫描技术,可以对超过传统系统容纳尺寸的部件进行高分辨率 CT 检测。然而,大型部件(如车身)通常会出现轨迹限制因素。使用具有恒定焦点-探测器-间距的传统轨迹可能会导致图像数据的各向异性,因为某些角度方向无法访问。在这项工作中,我们介绍了两种方法,通过整合不同聚焦-探测器-距离的投影,在扫描难以进入的区域时选择合适的采集点集。X 射线硬件的可变距离使其能够绕过碰撞结构,从而促进对缺失角度方向的扫描。最初的方法是沿着球形轨迹纳入无碰撞视点,通过保持焦点-物体-距离和物体-探测器-距离之间的比率恒定来保留视野,同时谨慎地延长焦点-探测器-距离。第二种方法代表了一种更直接的方法,通过绕过这些碰撞元素周围的 X 射线源,可以扫描以前在传统圆形轨迹上无法进入的角扇区。在定性和定量评估中,我们将以恒定探焦距离为特征的传统轨迹与采用可变探焦距离的拟议技术进行了对比,结果表明,所开发的方法提高了有限可达性扫描的物体结构可解释性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Selecting Feasible Trajectories for Robot-Based X-ray Tomography by Varying Focus-Detector-Distance in Space Restricted Environments

Computed tomography has evolved as an essential tool for non-destructive testing within the automotive industry. The application of robot-based computed tomography enables high-resolution CT inspections of components exceeding the dimensions accommodated by conventional systems. However, large-scale components, e.g. vehicle bodies, often exhibit trajectory-limiting elements. The utilization of conventional trajectories with constant Focus-Detector-Distances can lead to anisotropy in image data due to the inaccessibility of some angular directions. In this work, we introduce two approaches that are able to select suitable acquisitions point sets in scans of challenging to access regions through the integration of projections with varying Focus-Detector-Distances. The variable distances of the X-ray hardware enable the capability to navigate around collision structures, thus facilitating the scanning of absent angular directions. The initial approach incorporates collision-free viewpoints along a spherical trajectory, preserving the field of view by maintaining a constant ratio between the Focus-Object-Distance and the Object-Detector-Distance, while discreetly extending the Focus-Detector-Distance. The second methodology represents a more straightforward approach, enabling the scanning of angular sectors that were previously inaccessible on the conventional circular trajectory by circumventing the X-ray source around these collision elements. Both the qualitative and quantitative evaluations, contrasting classical trajectories characterized by constant Focus-Detector-Distances with the proposed techniques employing variable Focus-Detector-Distances, indicate that the developed methods improve the object structure interpretability for scans of limited accessibility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Nondestructive Evaluation
Journal of Nondestructive Evaluation 工程技术-材料科学:表征与测试
CiteScore
4.90
自引率
7.10%
发文量
67
审稿时长
9 months
期刊介绍: Journal of Nondestructive Evaluation provides a forum for the broad range of scientific and engineering activities involved in developing a quantitative nondestructive evaluation (NDE) capability. This interdisciplinary journal publishes papers on the development of new equipment, analyses, and approaches to nondestructive measurements.
期刊最新文献
Electromagnetic Radiation Characteristics and Mechanical Properties of Cement-Mortar Under Impact Load Instance Segmentation XXL-CT Challenge of a Historic Airplane Publisher Correction: Intelligent Extraction of Surface Cracks on LNG Outer Tanks Based on Close-Range Image Point Clouds and Infrared Imagery Acoustic Emission Signal Feature Extraction for Bearing Faults Using ACF and GMOMEDA Modeling and Analysis of Ellipticity Dispersion Characteristics of Lamb Waves in Pre-stressed Plates
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1