{"title":"测试深度学习模型在诊所中的通用性和有效性:精子检测试点研究。","authors":"Jiaqi Wang, Yufei Jin, Aojun Jiang, Wenyuan Chen, Guanqiao Shan, Yifan Gu, Yue Ming, Jichang Li, Chunfeng Yue, Zongjie Huang, Clifford Librach, Ge Lin, Xibu Wang, Huan Zhao, Yu Sun, Zhuoran Zhang","doi":"10.1186/s12958-024-01232-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Deep learning has been increasingly investigated for assisting clinical in vitro fertilization (IVF). The first technical step in many tasks is to visually detect and locate sperm, oocytes, and embryos in images. For clinical deployment of such deep learning models, different clinics use different image acquisition hardware and different sample preprocessing protocols, raising the concern over whether the reported accuracy of a deep learning model by one clinic could be reproduced in another clinic. Here we aim to investigate the effect of each imaging factor on the generalizability of object detection models, using sperm analysis as a pilot example.</p><p><strong>Methods: </strong>Ablation studies were performed using state-of-the-art models for detecting human sperm to quantitatively assess how model precision (false-positive detection) and recall (missed detection) were affected by imaging magnification, imaging mode, and sample preprocessing protocols. The results led to the hypothesis that the richness of image acquisition conditions in a training dataset deterministically affects model generalizability. The hypothesis was tested by first enriching the training dataset with a wide range of imaging conditions, then validated through internal blind tests on new samples and external multi-center clinical validations.</p><p><strong>Results: </strong>Ablation experiments revealed that removing subsets of data from the training dataset significantly reduced model precision. Removing raw sample images from the training dataset caused the largest drop in model precision, whereas removing 20x images caused the largest drop in model recall. by incorporating different imaging and sample preprocessing conditions into a rich training dataset, the model achieved an intraclass correlation coefficient (ICC) of 0.97 (95% CI: 0.94-0.99) for precision, and an ICC of 0.97 (95% CI: 0.93-0.99) for recall. Multi-center clinical validation showed no significant differences in model precision or recall across different clinics and applications.</p><p><strong>Conclusions: </strong>The results validated the hypothesis that the richness of data in the training dataset is a key factor impacting model generalizability. These findings highlight the importance of diversity in a training dataset for model evaluation and suggest that future deep learning models in andrology and reproductive medicine should incorporate comprehensive feature sets for enhanced generalizability across clinics.</p>","PeriodicalId":21011,"journal":{"name":"Reproductive Biology and Endocrinology","volume":"22 1","pages":"59"},"PeriodicalIF":4.2000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11110326/pdf/","citationCount":"0","resultStr":"{\"title\":\"Testing the generalizability and effectiveness of deep learning models among clinics: sperm detection as a pilot study.\",\"authors\":\"Jiaqi Wang, Yufei Jin, Aojun Jiang, Wenyuan Chen, Guanqiao Shan, Yifan Gu, Yue Ming, Jichang Li, Chunfeng Yue, Zongjie Huang, Clifford Librach, Ge Lin, Xibu Wang, Huan Zhao, Yu Sun, Zhuoran Zhang\",\"doi\":\"10.1186/s12958-024-01232-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Deep learning has been increasingly investigated for assisting clinical in vitro fertilization (IVF). The first technical step in many tasks is to visually detect and locate sperm, oocytes, and embryos in images. For clinical deployment of such deep learning models, different clinics use different image acquisition hardware and different sample preprocessing protocols, raising the concern over whether the reported accuracy of a deep learning model by one clinic could be reproduced in another clinic. Here we aim to investigate the effect of each imaging factor on the generalizability of object detection models, using sperm analysis as a pilot example.</p><p><strong>Methods: </strong>Ablation studies were performed using state-of-the-art models for detecting human sperm to quantitatively assess how model precision (false-positive detection) and recall (missed detection) were affected by imaging magnification, imaging mode, and sample preprocessing protocols. The results led to the hypothesis that the richness of image acquisition conditions in a training dataset deterministically affects model generalizability. The hypothesis was tested by first enriching the training dataset with a wide range of imaging conditions, then validated through internal blind tests on new samples and external multi-center clinical validations.</p><p><strong>Results: </strong>Ablation experiments revealed that removing subsets of data from the training dataset significantly reduced model precision. Removing raw sample images from the training dataset caused the largest drop in model precision, whereas removing 20x images caused the largest drop in model recall. by incorporating different imaging and sample preprocessing conditions into a rich training dataset, the model achieved an intraclass correlation coefficient (ICC) of 0.97 (95% CI: 0.94-0.99) for precision, and an ICC of 0.97 (95% CI: 0.93-0.99) for recall. Multi-center clinical validation showed no significant differences in model precision or recall across different clinics and applications.</p><p><strong>Conclusions: </strong>The results validated the hypothesis that the richness of data in the training dataset is a key factor impacting model generalizability. These findings highlight the importance of diversity in a training dataset for model evaluation and suggest that future deep learning models in andrology and reproductive medicine should incorporate comprehensive feature sets for enhanced generalizability across clinics.</p>\",\"PeriodicalId\":21011,\"journal\":{\"name\":\"Reproductive Biology and Endocrinology\",\"volume\":\"22 1\",\"pages\":\"59\"},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2024-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11110326/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reproductive Biology and Endocrinology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12958-024-01232-8\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reproductive Biology and Endocrinology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12958-024-01232-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
Testing the generalizability and effectiveness of deep learning models among clinics: sperm detection as a pilot study.
Background: Deep learning has been increasingly investigated for assisting clinical in vitro fertilization (IVF). The first technical step in many tasks is to visually detect and locate sperm, oocytes, and embryos in images. For clinical deployment of such deep learning models, different clinics use different image acquisition hardware and different sample preprocessing protocols, raising the concern over whether the reported accuracy of a deep learning model by one clinic could be reproduced in another clinic. Here we aim to investigate the effect of each imaging factor on the generalizability of object detection models, using sperm analysis as a pilot example.
Methods: Ablation studies were performed using state-of-the-art models for detecting human sperm to quantitatively assess how model precision (false-positive detection) and recall (missed detection) were affected by imaging magnification, imaging mode, and sample preprocessing protocols. The results led to the hypothesis that the richness of image acquisition conditions in a training dataset deterministically affects model generalizability. The hypothesis was tested by first enriching the training dataset with a wide range of imaging conditions, then validated through internal blind tests on new samples and external multi-center clinical validations.
Results: Ablation experiments revealed that removing subsets of data from the training dataset significantly reduced model precision. Removing raw sample images from the training dataset caused the largest drop in model precision, whereas removing 20x images caused the largest drop in model recall. by incorporating different imaging and sample preprocessing conditions into a rich training dataset, the model achieved an intraclass correlation coefficient (ICC) of 0.97 (95% CI: 0.94-0.99) for precision, and an ICC of 0.97 (95% CI: 0.93-0.99) for recall. Multi-center clinical validation showed no significant differences in model precision or recall across different clinics and applications.
Conclusions: The results validated the hypothesis that the richness of data in the training dataset is a key factor impacting model generalizability. These findings highlight the importance of diversity in a training dataset for model evaluation and suggest that future deep learning models in andrology and reproductive medicine should incorporate comprehensive feature sets for enhanced generalizability across clinics.
期刊介绍:
Reproductive Biology and Endocrinology publishes and disseminates high-quality results from excellent research in the reproductive sciences.
The journal publishes on topics covering gametogenesis, fertilization, early embryonic development, embryo-uterus interaction, reproductive development, pregnancy, uterine biology, endocrinology of reproduction, control of reproduction, reproductive immunology, neuroendocrinology, and veterinary and human reproductive medicine, including all vertebrate species.