对表面硬化的工业混凝土地面过早损坏进行诊断

IF 0.5 4区 工程技术 Q4 CONSTRUCTION & BUILDING TECHNOLOGY Cement Wapno Beton Pub Date : 2024-06-05 DOI:10.32047/cwb.2023.28.6.4
M. Glinicki, D. Jóźwiak-Niedźwiedzka, Andrzej M. Brandt
{"title":"对表面硬化的工业混凝土地面过早损坏进行诊断","authors":"M. Glinicki, D. Jóźwiak-Niedźwiedzka, Andrzej M. Brandt","doi":"10.32047/cwb.2023.28.6.4","DOIUrl":null,"url":null,"abstract":"The article presents the diagnostic results on surface-hardened industrial concrete floors. Selected examples of floors showcased premature damage to surface layers, characterized by intense dusting, delamination, and local spalling, while the structural system remained unaffected. Quantitative petrographic analysis of concrete was applied to core specimens from the floors, involving the examination of digital images from a polarizing optical microscope and a scanning electron microscope. The hardening compound and powdered specimens of the cement matrix were characterized using differential thermal analysis and X-ray diffraction. A multiple microindentation method was employed to assess local variations in mechanical properties. Concrete cross-section analysis revealed areas with a non-uniform distribution of air voids, identified regions exhibiting increased porosity, highlighted areas of cracking in the concrete, indicated local variability in the phase composition of cement hydration products, and pointed out the presence of carbonated areas. The causes of the damage were discussed based on these findings,. The crucial role of quantitative petrographic analysis in diagnosing premature surface damage to industrial floors was demonstrated.","PeriodicalId":55632,"journal":{"name":"Cement Wapno Beton","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostics of premature damage to surface-hardened industrial concrete floors\",\"authors\":\"M. Glinicki, D. Jóźwiak-Niedźwiedzka, Andrzej M. Brandt\",\"doi\":\"10.32047/cwb.2023.28.6.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article presents the diagnostic results on surface-hardened industrial concrete floors. Selected examples of floors showcased premature damage to surface layers, characterized by intense dusting, delamination, and local spalling, while the structural system remained unaffected. Quantitative petrographic analysis of concrete was applied to core specimens from the floors, involving the examination of digital images from a polarizing optical microscope and a scanning electron microscope. The hardening compound and powdered specimens of the cement matrix were characterized using differential thermal analysis and X-ray diffraction. A multiple microindentation method was employed to assess local variations in mechanical properties. Concrete cross-section analysis revealed areas with a non-uniform distribution of air voids, identified regions exhibiting increased porosity, highlighted areas of cracking in the concrete, indicated local variability in the phase composition of cement hydration products, and pointed out the presence of carbonated areas. The causes of the damage were discussed based on these findings,. The crucial role of quantitative petrographic analysis in diagnosing premature surface damage to industrial floors was demonstrated.\",\"PeriodicalId\":55632,\"journal\":{\"name\":\"Cement Wapno Beton\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cement Wapno Beton\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.32047/cwb.2023.28.6.4\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cement Wapno Beton","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.32047/cwb.2023.28.6.4","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

文章介绍了对表面硬化的工业混凝土地面的诊断结果。所选地板实例显示了表层的过早损坏,其特点是严重起灰、分层和局部剥落,而结构系统则未受影响。通过偏光光学显微镜和扫描电子显微镜的数字图像检查,对来自地面的核心试样进行了混凝土定量岩相分析。利用差热分析和 X 射线衍射对硬化化合物和水泥基质粉末试样进行了表征。采用多重微压痕法评估了机械性能的局部变化。混凝土横截面分析显示了气孔分布不均匀的区域,确定了孔隙率增加的区域,突出了混凝土开裂的区域,显示了水泥水化产物相组成的局部变化,并指出了碳化区域的存在。根据这些发现讨论了损坏的原因。定量岩相分析在诊断工业地面过早表面损坏方面的关键作用得到了证明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Diagnostics of premature damage to surface-hardened industrial concrete floors
The article presents the diagnostic results on surface-hardened industrial concrete floors. Selected examples of floors showcased premature damage to surface layers, characterized by intense dusting, delamination, and local spalling, while the structural system remained unaffected. Quantitative petrographic analysis of concrete was applied to core specimens from the floors, involving the examination of digital images from a polarizing optical microscope and a scanning electron microscope. The hardening compound and powdered specimens of the cement matrix were characterized using differential thermal analysis and X-ray diffraction. A multiple microindentation method was employed to assess local variations in mechanical properties. Concrete cross-section analysis revealed areas with a non-uniform distribution of air voids, identified regions exhibiting increased porosity, highlighted areas of cracking in the concrete, indicated local variability in the phase composition of cement hydration products, and pointed out the presence of carbonated areas. The causes of the damage were discussed based on these findings,. The crucial role of quantitative petrographic analysis in diagnosing premature surface damage to industrial floors was demonstrated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cement Wapno Beton
Cement Wapno Beton CONSTRUCTION & BUILDING TECHNOLOGY-MATERIALS SCIENCE, COMPOSITES
CiteScore
1.30
自引率
28.60%
发文量
0
审稿时长
>12 weeks
期刊介绍: The Publisher of the scientific bimonthly of international circulation, entitled "Cement-Wapno-Beton" ["Cement-Lime-Concrete"], is the Fundacja Cement, Wapno, Beton [Foundation Cement, Lime, Concrete]. The periodical is dedicated to the issues concerning mineral setting materials and concrete. It is concerned with the publication of academic and research works from the field of chemistry and technology of building setting materials and concrete
期刊最新文献
Investigation of calcite and huntite/hydromagnesite mineral in co-presence regarding flame retardant and mechanical properties of wood composites Durability self-compacting mortar under external chemical attacks based on composite binder Perspective of concrete with Portland composite cement CEM II/C-M (S-LL) Transport Properties of Internally Cured Self Compacting Concrete with Fly Ash Environmental Assessment of Construction Products – Challenges, Priorities, and Needs from Producers’ Perspective. A Review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1