{"title":"间接比较用于 EUS 引导下胆道和胆囊引流的各种管腔贴壁金属支架:系统回顾和荟萃分析。","authors":"","doi":"10.1016/j.gie.2024.05.024","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aims</h3><div>Studies assessing EUS-guided biliary drainage (EUS-BD) or gallbladder drainage (EUS-GB) using lumen-apposing metal stents (LAMSs) have shown variable results based on the type of LAMS. We performed a meta-analysis of the available data.</div></div><div><h3>Methods</h3><div>Multiple online databases were searched for studies using LAMSs (Axios [Boston Scientific, Marlborough, Mass, USA] or Spaxus [Taewoong Medical Co, Gimpo, Korea]) for EUS-BD and EUS-GB. The outcomes of interest were technical success, clinical success, and adverse events. Pooled proportions along with 95% confidence intervals were calculated.</div></div><div><h3>Results</h3><div>A total of 18 observational studies were included: 11 for the Axios stent (433 patients; mean age, 72 years; 54% male) and 7 for the Spaxus stent (242 patients; mean age, 74 years; 50% male). The respective pooled outcomes for the Axios stent (EUS-BD and EUS-GB, respectively) were technical success, 96.2% and 96.2%; clinical success, 92.8% and 92.7%; total adverse events, 10.1% and 23.6%; and bleeding, 3.7% and 4.8%. The respective pooled outcomes for the Spaxus stent (EUS-BD and EUS-GB, respectively) were technical success, 93.8% and 95.9%; clinical success, 90.1% and 94.2%; total adverse events, 12.6% and 9.5%; and bleeding, 3.1% and 1.8%.</div></div><div><h3>Conclusions</h3><div>Axios and Spaxus stents demonstrate similar pooled technical and clinical success rates. Adverse events occurred in 23.6% of patients (Axios stent) and 9.5% of patients (Spaxus stent) during EUS-GB.</div></div>","PeriodicalId":12542,"journal":{"name":"Gastrointestinal endoscopy","volume":"100 5","pages":"Pages 829-839.e3"},"PeriodicalIF":6.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Indirect comparison of various lumen-apposing metal stents for EUS-guided biliary and gallbladder drainage: a systematic review and meta-analysis\",\"authors\":\"\",\"doi\":\"10.1016/j.gie.2024.05.024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background and Aims</h3><div>Studies assessing EUS-guided biliary drainage (EUS-BD) or gallbladder drainage (EUS-GB) using lumen-apposing metal stents (LAMSs) have shown variable results based on the type of LAMS. We performed a meta-analysis of the available data.</div></div><div><h3>Methods</h3><div>Multiple online databases were searched for studies using LAMSs (Axios [Boston Scientific, Marlborough, Mass, USA] or Spaxus [Taewoong Medical Co, Gimpo, Korea]) for EUS-BD and EUS-GB. The outcomes of interest were technical success, clinical success, and adverse events. Pooled proportions along with 95% confidence intervals were calculated.</div></div><div><h3>Results</h3><div>A total of 18 observational studies were included: 11 for the Axios stent (433 patients; mean age, 72 years; 54% male) and 7 for the Spaxus stent (242 patients; mean age, 74 years; 50% male). The respective pooled outcomes for the Axios stent (EUS-BD and EUS-GB, respectively) were technical success, 96.2% and 96.2%; clinical success, 92.8% and 92.7%; total adverse events, 10.1% and 23.6%; and bleeding, 3.7% and 4.8%. The respective pooled outcomes for the Spaxus stent (EUS-BD and EUS-GB, respectively) were technical success, 93.8% and 95.9%; clinical success, 90.1% and 94.2%; total adverse events, 12.6% and 9.5%; and bleeding, 3.1% and 1.8%.</div></div><div><h3>Conclusions</h3><div>Axios and Spaxus stents demonstrate similar pooled technical and clinical success rates. Adverse events occurred in 23.6% of patients (Axios stent) and 9.5% of patients (Spaxus stent) during EUS-GB.</div></div>\",\"PeriodicalId\":12542,\"journal\":{\"name\":\"Gastrointestinal endoscopy\",\"volume\":\"100 5\",\"pages\":\"Pages 829-839.e3\"},\"PeriodicalIF\":6.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gastrointestinal endoscopy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0016510724032619\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gastrointestinal endoscopy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0016510724032619","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
Indirect comparison of various lumen-apposing metal stents for EUS-guided biliary and gallbladder drainage: a systematic review and meta-analysis
Background and Aims
Studies assessing EUS-guided biliary drainage (EUS-BD) or gallbladder drainage (EUS-GB) using lumen-apposing metal stents (LAMSs) have shown variable results based on the type of LAMS. We performed a meta-analysis of the available data.
Methods
Multiple online databases were searched for studies using LAMSs (Axios [Boston Scientific, Marlborough, Mass, USA] or Spaxus [Taewoong Medical Co, Gimpo, Korea]) for EUS-BD and EUS-GB. The outcomes of interest were technical success, clinical success, and adverse events. Pooled proportions along with 95% confidence intervals were calculated.
Results
A total of 18 observational studies were included: 11 for the Axios stent (433 patients; mean age, 72 years; 54% male) and 7 for the Spaxus stent (242 patients; mean age, 74 years; 50% male). The respective pooled outcomes for the Axios stent (EUS-BD and EUS-GB, respectively) were technical success, 96.2% and 96.2%; clinical success, 92.8% and 92.7%; total adverse events, 10.1% and 23.6%; and bleeding, 3.7% and 4.8%. The respective pooled outcomes for the Spaxus stent (EUS-BD and EUS-GB, respectively) were technical success, 93.8% and 95.9%; clinical success, 90.1% and 94.2%; total adverse events, 12.6% and 9.5%; and bleeding, 3.1% and 1.8%.
Conclusions
Axios and Spaxus stents demonstrate similar pooled technical and clinical success rates. Adverse events occurred in 23.6% of patients (Axios stent) and 9.5% of patients (Spaxus stent) during EUS-GB.
期刊介绍:
Gastrointestinal Endoscopy is a journal publishing original, peer-reviewed articles on endoscopic procedures for studying, diagnosing, and treating digestive diseases. It covers outcomes research, prospective studies, and controlled trials of new endoscopic instruments and treatment methods. The online features include full-text articles, video and audio clips, and MEDLINE links. The journal serves as an international forum for the latest developments in the specialty, offering challenging reports from authorities worldwide. It also publishes abstracts of significant articles from other clinical publications, accompanied by expert commentaries.