Amanda Rodrigues , Gabriela Ferreira Carvalho , Lidiane Lima Florencio , Jaqueline Martins , Carina Ferreira Pinheiro-Araújo , Milena Dietrich Deitos Rosa , Fabíola Dach , Débora Bevilaqua-Grossi
{"title":"偏头痛患者颅颈屈曲测试的可靠性和结构有效性","authors":"Amanda Rodrigues , Gabriela Ferreira Carvalho , Lidiane Lima Florencio , Jaqueline Martins , Carina Ferreira Pinheiro-Araújo , Milena Dietrich Deitos Rosa , Fabíola Dach , Débora Bevilaqua-Grossi","doi":"10.1016/j.bjpt.2024.101085","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.</p></div><div><h3>Objectives</h3><p>To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.</p></div><div><h3>Methods</h3><p>Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7–10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test – 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.</p></div><div><h3>Results</h3><p>A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (<em>p</em> = 0.004, <em>R</em> = 0.35).</p></div><div><h3>Conclusion</h3><p>The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.</p></div>","PeriodicalId":49621,"journal":{"name":"Brazilian Journal of Physical Therapy","volume":"28 4","pages":"Article 101085"},"PeriodicalIF":3.1000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability and construct validity of the Craniocervical Flexion Test in patients with migraine\",\"authors\":\"Amanda Rodrigues , Gabriela Ferreira Carvalho , Lidiane Lima Florencio , Jaqueline Martins , Carina Ferreira Pinheiro-Araújo , Milena Dietrich Deitos Rosa , Fabíola Dach , Débora Bevilaqua-Grossi\",\"doi\":\"10.1016/j.bjpt.2024.101085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.</p></div><div><h3>Objectives</h3><p>To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.</p></div><div><h3>Methods</h3><p>Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7–10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test – 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.</p></div><div><h3>Results</h3><p>A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (<em>p</em> = 0.004, <em>R</em> = 0.35).</p></div><div><h3>Conclusion</h3><p>The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.</p></div>\",\"PeriodicalId\":49621,\"journal\":{\"name\":\"Brazilian Journal of Physical Therapy\",\"volume\":\"28 4\",\"pages\":\"Article 101085\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Journal of Physical Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1413355524004957\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Physical Therapy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1413355524004957","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Reliability and construct validity of the Craniocervical Flexion Test in patients with migraine
Background
Migraine may be accompanied by several cervical musculoskeletal dysfunctions, for example an altered performance on the Craniocervical Flexion Test (CCFT). However, CCFT measurement properties are still unclear in patients with migraine.
Objectives
To determine intra- and inter-examiner reliability, construct validity, standard measurement error (SEM), and minimal detectable change (MDC) of the CCFT in patients with migraine.
Methods
Women diagnosed with migraine were considered eligible for this study. Participants were assessed by two examiners for the inter-examiner reliability, and with 7–10 days interval for the intra-examiner reliability. Construct validity was assessed considering headache and neck pain frequency and intensity, and self-reported questionnaires, including the Headache Impact Test – 6 items (HIT-6), the 12-item Allodynia Symptom Checklist/Brazil (ASC-12), and the Neck Disability Index (NDI). In addition, participants performed cervical endurance and maximal voluntary isometric contraction of the cervical flexors.
Results
A total of 103 women with migraine were recruited. The intra-examiner reliability was rated as good (ICC= 0.81, 95% CI: 0.73, 0.87), while the inter-examiner reliability was rated as moderate (ICC= 0.55, 95% CI: 0.40, 0.67). The intra and inter-examiner SEM were 1.31 and 1.36 mmHg respectively, and MDC were 3.63 and 3.77 mmHg. The HIT-6 and the cervical endurance flexion test were associated with the CCFT in a multiple linear regression model (p = 0.004, R = 0.35).
Conclusion
The CCFT presents adequate intra- and inter-examiner reliability. Better performance on the CCFT test was associated with better HIT-6 scores and greater cervical endurance time, which was not influenced by the presence of neck pain.
期刊介绍:
The Brazilian Journal of Physical Therapy (BJPT) is the official publication of the Brazilian Society of Physical Therapy Research and Graduate Studies (ABRAPG-Ft). It publishes original research articles on topics related to the areas of physical therapy and rehabilitation sciences, including clinical, basic or applied studies on the assessment, prevention, and treatment of movement disorders.