Que N N Tran, Takeshi Moriguchi, Masateru Ueno, Tomohiko Iwano, Kentaro Yoshimura
{"title":"基于环境质谱和机器学习的急性冠状动脉综合征诊断系统。","authors":"Que N N Tran, Takeshi Moriguchi, Masateru Ueno, Tomohiko Iwano, Kentaro Yoshimura","doi":"10.5702/massspectrometry.A0147","DOIUrl":null,"url":null,"abstract":"<p><p><b>Aims:</b> The purpose of this study is to establish a novel diagnosis system in early acute coronary syndrome (ACS) using probe electrospray ionization-mass spectrometry (PESI-MS) and machine learning (ML) and to validate the diagnostic accuracy. <b>Methods:</b> A total of 32 serum samples derived from 16 ACS patients and 16 control patients were analyzed by PESI-MS. The acquired mass spectrum dataset was subsequently analyzed by partial least squares (PLS) regression to find the relationship between the two groups. A support vector machine, an ML method, was applied to the dataset to construct the diagnostic algorithm. <b>Results:</b> Control and ACS groups were separated into the two clusters in the PLS plot, indicating ACS patients differed from the control in the profile of serum composition obtained by PESI-MS. The sensitivity, specificity, and accuracy of our diagnostic system were all 93.8%, and the area under the receiver operating characteristic curve showed 0.965 (95% CI: 0.84-1). <b>Conclusion:</b> The PESI-MS and ML-based diagnosis system are likely an optimal solution to assist physicians in ACS diagnosis with its remarkably predictive accuracy.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"13 1","pages":"A0147"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11239961/pdf/","citationCount":"0","resultStr":"{\"title\":\"Ambient Mass Spectrometry and Machine Learning-Based Diagnosis System for Acute Coronary Syndrome.\",\"authors\":\"Que N N Tran, Takeshi Moriguchi, Masateru Ueno, Tomohiko Iwano, Kentaro Yoshimura\",\"doi\":\"10.5702/massspectrometry.A0147\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Aims:</b> The purpose of this study is to establish a novel diagnosis system in early acute coronary syndrome (ACS) using probe electrospray ionization-mass spectrometry (PESI-MS) and machine learning (ML) and to validate the diagnostic accuracy. <b>Methods:</b> A total of 32 serum samples derived from 16 ACS patients and 16 control patients were analyzed by PESI-MS. The acquired mass spectrum dataset was subsequently analyzed by partial least squares (PLS) regression to find the relationship between the two groups. A support vector machine, an ML method, was applied to the dataset to construct the diagnostic algorithm. <b>Results:</b> Control and ACS groups were separated into the two clusters in the PLS plot, indicating ACS patients differed from the control in the profile of serum composition obtained by PESI-MS. The sensitivity, specificity, and accuracy of our diagnostic system were all 93.8%, and the area under the receiver operating characteristic curve showed 0.965 (95% CI: 0.84-1). <b>Conclusion:</b> The PESI-MS and ML-based diagnosis system are likely an optimal solution to assist physicians in ACS diagnosis with its remarkably predictive accuracy.</p>\",\"PeriodicalId\":18243,\"journal\":{\"name\":\"Mass spectrometry\",\"volume\":\"13 1\",\"pages\":\"A0147\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11239961/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mass spectrometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5702/massspectrometry.A0147\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5702/massspectrometry.A0147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
Ambient Mass Spectrometry and Machine Learning-Based Diagnosis System for Acute Coronary Syndrome.
Aims: The purpose of this study is to establish a novel diagnosis system in early acute coronary syndrome (ACS) using probe electrospray ionization-mass spectrometry (PESI-MS) and machine learning (ML) and to validate the diagnostic accuracy. Methods: A total of 32 serum samples derived from 16 ACS patients and 16 control patients were analyzed by PESI-MS. The acquired mass spectrum dataset was subsequently analyzed by partial least squares (PLS) regression to find the relationship between the two groups. A support vector machine, an ML method, was applied to the dataset to construct the diagnostic algorithm. Results: Control and ACS groups were separated into the two clusters in the PLS plot, indicating ACS patients differed from the control in the profile of serum composition obtained by PESI-MS. The sensitivity, specificity, and accuracy of our diagnostic system were all 93.8%, and the area under the receiver operating characteristic curve showed 0.965 (95% CI: 0.84-1). Conclusion: The PESI-MS and ML-based diagnosis system are likely an optimal solution to assist physicians in ACS diagnosis with its remarkably predictive accuracy.