打印层厚度对纳米复合 3D 打印树脂抗弯强度的影响:体外比较研究

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Saudi Dental Journal Pub Date : 2024-10-01 DOI:10.1016/j.sdentj.2024.07.009
Mohammed M. Gad , Fatimah Abdullah Alzaki , Fatimah Ahmed Abuwarwar , Ali Alhammad , Mohammed Al Hussain , Soban Q. Khan , Essam A. Nassar , Neveen M. Ayad
{"title":"打印层厚度对纳米复合 3D 打印树脂抗弯强度的影响:体外比较研究","authors":"Mohammed M. Gad ,&nbsp;Fatimah Abdullah Alzaki ,&nbsp;Fatimah Ahmed Abuwarwar ,&nbsp;Ali Alhammad ,&nbsp;Mohammed Al Hussain ,&nbsp;Soban Q. Khan ,&nbsp;Essam A. Nassar ,&nbsp;Neveen M. Ayad","doi":"10.1016/j.sdentj.2024.07.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>This study evaluated the influence of various printing layer thicknesses with silicon dioxide nanoparticles (SiO<sub>2</sub>NPs) incorporated as a reinforcement material on the flexural strength of 3D-printed denture base resins.</div></div><div><h3>Material and Methods</h3><div>Asiga (DentaBASE, Asiga, Erfurt, Germany) and NextDent (Denture 3D+, NextDent B.V., Soesterberg, The Netherlands) 3D-printed resins were modified with different concentrations of SiO<sub>2</sub>NPs (0.25 % and 0.5 wt%). A total of 180 specimens (bar-shaped, 64 × 10 × 3.3 mm) were fabricated (N = 90/resin). Each resin was subdivided into three groups (n = 30) according to the SiO<sub>2</sub>NP concentration (0 %, 0.25 %, and 0.5 wt%) Each concentration was divided into three groups (n = 10) according to the printing layer thickness (50 µm, 75 µm, and 100 µm). Specimens were printed according to the manufacturer’s instructions and then subjected to 10,000 thermal cycles. A three-point bending test was used to measure the flexural strength (MPa). One-way analysis of variance (ANOVA) and Tukey’s post hoc tests were used to analyze the data (α = 0.05).</div></div><div><h3>Results</h3><div>For both resins, printing layer thicknesses of 50 µm and 75 µm exhibited significantly higher flexural strength than 100 µm (P &lt; 0.001). The 50 µm thickness showed the greatest flexural strength values (81.65 ± 4.77 MPa and 84.59 ± 6.21 MPa for Asiga and NextDent, respectively). The 100 µm thickness showed the lowest flexural strength values (74.35 ± 5.37 and 73.66 ± 5.55 MPa) for Asiga and NextDent, respectively. The flexural strength significantly increased with the addition of SiO<sub>2</sub>NPs with printing layer thicknesses of 50 µm and 75 µm (P &lt; 0.001), whereas the modified and unmodified groups printed with a 100 µm layer thickness did not differ significantly. Asiga 0.25 %/50 µm and NextDent 0.5 %/50 µm showed the highest flexural strength values (97.32 ± 6.82 MPa and 97.54 ± 7.04 MPa, respectively). Scanning electron microscopy fractured surfaces analysis revealed more lamellae and irregularities with lower printing layer thicknesses and SiO<sub>2</sub>NP concentrations.</div></div><div><h3>Conclusion</h3><div>The flexural strength increased with printing layer thicknesses of 50 µm or 75 µm combined with SiO<sub>2</sub>NP reinforcement.</div></div>","PeriodicalId":47246,"journal":{"name":"Saudi Dental Journal","volume":"36 10","pages":"Pages 1307-1312"},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of printing layer thickness on the flexural strength of nanocomposite 3D printed resins: An in vitro comparative study\",\"authors\":\"Mohammed M. Gad ,&nbsp;Fatimah Abdullah Alzaki ,&nbsp;Fatimah Ahmed Abuwarwar ,&nbsp;Ali Alhammad ,&nbsp;Mohammed Al Hussain ,&nbsp;Soban Q. Khan ,&nbsp;Essam A. Nassar ,&nbsp;Neveen M. Ayad\",\"doi\":\"10.1016/j.sdentj.2024.07.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>This study evaluated the influence of various printing layer thicknesses with silicon dioxide nanoparticles (SiO<sub>2</sub>NPs) incorporated as a reinforcement material on the flexural strength of 3D-printed denture base resins.</div></div><div><h3>Material and Methods</h3><div>Asiga (DentaBASE, Asiga, Erfurt, Germany) and NextDent (Denture 3D+, NextDent B.V., Soesterberg, The Netherlands) 3D-printed resins were modified with different concentrations of SiO<sub>2</sub>NPs (0.25 % and 0.5 wt%). A total of 180 specimens (bar-shaped, 64 × 10 × 3.3 mm) were fabricated (N = 90/resin). Each resin was subdivided into three groups (n = 30) according to the SiO<sub>2</sub>NP concentration (0 %, 0.25 %, and 0.5 wt%) Each concentration was divided into three groups (n = 10) according to the printing layer thickness (50 µm, 75 µm, and 100 µm). Specimens were printed according to the manufacturer’s instructions and then subjected to 10,000 thermal cycles. A three-point bending test was used to measure the flexural strength (MPa). One-way analysis of variance (ANOVA) and Tukey’s post hoc tests were used to analyze the data (α = 0.05).</div></div><div><h3>Results</h3><div>For both resins, printing layer thicknesses of 50 µm and 75 µm exhibited significantly higher flexural strength than 100 µm (P &lt; 0.001). The 50 µm thickness showed the greatest flexural strength values (81.65 ± 4.77 MPa and 84.59 ± 6.21 MPa for Asiga and NextDent, respectively). The 100 µm thickness showed the lowest flexural strength values (74.35 ± 5.37 and 73.66 ± 5.55 MPa) for Asiga and NextDent, respectively. The flexural strength significantly increased with the addition of SiO<sub>2</sub>NPs with printing layer thicknesses of 50 µm and 75 µm (P &lt; 0.001), whereas the modified and unmodified groups printed with a 100 µm layer thickness did not differ significantly. Asiga 0.25 %/50 µm and NextDent 0.5 %/50 µm showed the highest flexural strength values (97.32 ± 6.82 MPa and 97.54 ± 7.04 MPa, respectively). Scanning electron microscopy fractured surfaces analysis revealed more lamellae and irregularities with lower printing layer thicknesses and SiO<sub>2</sub>NP concentrations.</div></div><div><h3>Conclusion</h3><div>The flexural strength increased with printing layer thicknesses of 50 µm or 75 µm combined with SiO<sub>2</sub>NP reinforcement.</div></div>\",\"PeriodicalId\":47246,\"journal\":{\"name\":\"Saudi Dental Journal\",\"volume\":\"36 10\",\"pages\":\"Pages 1307-1312\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Dental Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1013905224002062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1013905224002062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

材料和方法 使用不同浓度的二氧化硅纳米粒子(SiO2NPs)(0.25 % 和 0.5 wt%)对 Asiga(DentaBASE,Asiga,德国埃尔富特)和 NextDent(Denture 3D+,NextDent B.V.,荷兰 Soesterberg)三维打印树脂进行改性。共制作了 180 个试样(条形,64 × 10 × 3.3 毫米)(N = 90/树脂)。根据 SiO2NP 的浓度(0%、0.25% 和 0.5 wt%),每种树脂又分为三组(n = 30);根据印刷层的厚度(50 µm、75 µm 和 100 µm),每种浓度又分为三组(n = 10)。试样按照制造商的说明进行印刷,然后进行 10,000 次热循环。三点弯曲试验用于测量弯曲强度(兆帕)。结果对于两种树脂,印刷层厚度为 50 微米和 75 微米的弯曲强度明显高于 100 微米(P < 0.001)。50 微米厚度的抗折强度值最大(Asiga 和 NextDent 分别为 81.65 ± 4.77 兆帕和 84.59 ± 6.21 兆帕)。厚度为 100 微米的 Asiga 和 NextDent 的抗折强度值最低(分别为 74.35 ± 5.37 和 73.66 ± 5.55 兆帕)。在印刷层厚度为 50 µm 和 75 µm 时,添加 SiO2NPs 后的抗折强度明显增加(P < 0.001),而印刷层厚度为 100 µm 的改性组和未改性组没有明显差异。Asiga 0.25 %/50 µm 和 NextDent 0.5 %/50 µm 的抗折强度值最高(分别为 97.32 ± 6.82 MPa 和 97.54 ± 7.04 MPa)。扫描电子显微镜断裂表面分析表明,印刷层厚度和 SiO2NP 浓度越低,层状和不规则现象越多。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of printing layer thickness on the flexural strength of nanocomposite 3D printed resins: An in vitro comparative study

Background

This study evaluated the influence of various printing layer thicknesses with silicon dioxide nanoparticles (SiO2NPs) incorporated as a reinforcement material on the flexural strength of 3D-printed denture base resins.

Material and Methods

Asiga (DentaBASE, Asiga, Erfurt, Germany) and NextDent (Denture 3D+, NextDent B.V., Soesterberg, The Netherlands) 3D-printed resins were modified with different concentrations of SiO2NPs (0.25 % and 0.5 wt%). A total of 180 specimens (bar-shaped, 64 × 10 × 3.3 mm) were fabricated (N = 90/resin). Each resin was subdivided into three groups (n = 30) according to the SiO2NP concentration (0 %, 0.25 %, and 0.5 wt%) Each concentration was divided into three groups (n = 10) according to the printing layer thickness (50 µm, 75 µm, and 100 µm). Specimens were printed according to the manufacturer’s instructions and then subjected to 10,000 thermal cycles. A three-point bending test was used to measure the flexural strength (MPa). One-way analysis of variance (ANOVA) and Tukey’s post hoc tests were used to analyze the data (α = 0.05).

Results

For both resins, printing layer thicknesses of 50 µm and 75 µm exhibited significantly higher flexural strength than 100 µm (P < 0.001). The 50 µm thickness showed the greatest flexural strength values (81.65 ± 4.77 MPa and 84.59 ± 6.21 MPa for Asiga and NextDent, respectively). The 100 µm thickness showed the lowest flexural strength values (74.35 ± 5.37 and 73.66 ± 5.55 MPa) for Asiga and NextDent, respectively. The flexural strength significantly increased with the addition of SiO2NPs with printing layer thicknesses of 50 µm and 75 µm (P < 0.001), whereas the modified and unmodified groups printed with a 100 µm layer thickness did not differ significantly. Asiga 0.25 %/50 µm and NextDent 0.5 %/50 µm showed the highest flexural strength values (97.32 ± 6.82 MPa and 97.54 ± 7.04 MPa, respectively). Scanning electron microscopy fractured surfaces analysis revealed more lamellae and irregularities with lower printing layer thicknesses and SiO2NP concentrations.

Conclusion

The flexural strength increased with printing layer thicknesses of 50 µm or 75 µm combined with SiO2NP reinforcement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Saudi Dental Journal
Saudi Dental Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.60
自引率
0.00%
发文量
86
审稿时长
22 weeks
期刊介绍: Saudi Dental Journal is an English language, peer-reviewed scholarly publication in the area of dentistry. Saudi Dental Journal publishes original research and reviews on, but not limited to: • dental disease • clinical trials • dental equipment • new and experimental techniques • epidemiology and oral health • restorative dentistry • periodontology • endodontology • prosthodontics • paediatric dentistry • orthodontics and dental education Saudi Dental Journal is the official publication of the Saudi Dental Society and is published by King Saud University in collaboration with Elsevier and is edited by an international group of eminent researchers.
期刊最新文献
Editorial Board Assessing the quality of AI information from ChatGPT regarding oral surgery, preventive dentistry, and oral cancer: An exploration study An in vitro study of fluoride-preloaded halloysite nanotubes to enhance the fluoride release in conventional and resin-modified glass ionomer cements Association between dental diseases and stroke Drug delivery systems in periodontitis: A visualization and bibliometric analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1