基于人工智能的多示踪剂全身 PET 联合衰减和散射校正策略。

IF 3 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING EJNMMI Physics Pub Date : 2024-07-19 DOI:10.1186/s40658-024-00666-8
Hao Sun, Yanchao Huang, Debin Hu, Xiaotong Hong, Yazdan Salimi, Wenbing Lv, Hongwen Chen, Habib Zaidi, Hubing Wu, Lijun Lu
{"title":"基于人工智能的多示踪剂全身 PET 联合衰减和散射校正策略。","authors":"Hao Sun, Yanchao Huang, Debin Hu, Xiaotong Hong, Yazdan Salimi, Wenbing Lv, Hongwen Chen, Habib Zaidi, Hubing Wu, Lijun Lu","doi":"10.1186/s40658-024-00666-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Low-dose ungated CT is commonly used for total-body PET attenuation and scatter correction (ASC). However, CT-based ASC (CT-ASC) is limited by radiation dose risks of CT examinations, propagation of CT-based artifacts and potential mismatches between PET and CT. We demonstrate the feasibility of direct ASC for multi-tracer total-body PET in the image domain.</p><p><strong>Methods: </strong>Clinical uEXPLORER total-body PET/CT datasets of [<sup>18</sup>F]FDG (N = 52), [<sup>18</sup>F]FAPI (N = 46) and [<sup>68</sup>Ga]FAPI (N = 60) were retrospectively enrolled in this study. We developed an improved 3D conditional generative adversarial network (cGAN) to directly estimate attenuation and scatter-corrected PET images from non-attenuation and scatter-corrected (NASC) PET images. The feasibility of the proposed 3D cGAN-based ASC was validated using four training strategies: (1) Paired 3D NASC and CT-ASC PET images from three tracers were pooled into one centralized server (CZ-ASC). (2) Paired 3D NASC and CT-ASC PET images from each tracer were individually used (DL-ASC). (3) Paired NASC and CT-ASC PET images from one tracer ([<sup>18</sup>F]FDG) were used to train the networks, while the other two tracers were used for testing without fine-tuning (NFT-ASC). (4) The pre-trained networks of (3) were fine-tuned with two other tracers individually (FT-ASC). We trained all networks in fivefold cross-validation. The performance of all ASC methods was evaluated by qualitative and quantitative metrics using CT-ASC as the reference.</p><p><strong>Results: </strong>CZ-ASC, DL-ASC and FT-ASC showed comparable visual quality with CT-ASC for all tracers. CZ-ASC and DL-ASC resulted in a normalized mean absolute error (NMAE) of 8.51 ± 7.32% versus 7.36 ± 6.77% (p < 0.05), outperforming NASC (p < 0.0001) in [<sup>18</sup>F]FDG dataset. CZ-ASC, FT-ASC and DL-ASC led to NMAE of 6.44 ± 7.02%, 6.55 ± 5.89%, and 7.25 ± 6.33% in [<sup>18</sup>F]FAPI dataset, and NMAE of 5.53 ± 3.99%, 5.60 ± 4.02%, and 5.68 ± 4.12% in [<sup>68</sup>Ga]FAPI dataset, respectively. CZ-ASC, FT-ASC and DL-ASC were superior to NASC (p < 0.0001) and NFT-ASC (p < 0.0001) in terms of NMAE results.</p><p><strong>Conclusions: </strong>CZ-ASC, DL-ASC and FT-ASC demonstrated the feasibility of providing accurate and robust ASC for multi-tracer total-body PET, thereby reducing the radiation hazards to patients from redundant CT examinations. CZ-ASC and FT-ASC could outperform DL-ASC for cross-tracer total-body PET AC.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"11 1","pages":"66"},"PeriodicalIF":3.0000,"publicationDate":"2024-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11264498/pdf/","citationCount":"0","resultStr":"{\"title\":\"Artificial intelligence-based joint attenuation and scatter correction strategies for multi-tracer total-body PET.\",\"authors\":\"Hao Sun, Yanchao Huang, Debin Hu, Xiaotong Hong, Yazdan Salimi, Wenbing Lv, Hongwen Chen, Habib Zaidi, Hubing Wu, Lijun Lu\",\"doi\":\"10.1186/s40658-024-00666-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Low-dose ungated CT is commonly used for total-body PET attenuation and scatter correction (ASC). However, CT-based ASC (CT-ASC) is limited by radiation dose risks of CT examinations, propagation of CT-based artifacts and potential mismatches between PET and CT. We demonstrate the feasibility of direct ASC for multi-tracer total-body PET in the image domain.</p><p><strong>Methods: </strong>Clinical uEXPLORER total-body PET/CT datasets of [<sup>18</sup>F]FDG (N = 52), [<sup>18</sup>F]FAPI (N = 46) and [<sup>68</sup>Ga]FAPI (N = 60) were retrospectively enrolled in this study. We developed an improved 3D conditional generative adversarial network (cGAN) to directly estimate attenuation and scatter-corrected PET images from non-attenuation and scatter-corrected (NASC) PET images. The feasibility of the proposed 3D cGAN-based ASC was validated using four training strategies: (1) Paired 3D NASC and CT-ASC PET images from three tracers were pooled into one centralized server (CZ-ASC). (2) Paired 3D NASC and CT-ASC PET images from each tracer were individually used (DL-ASC). (3) Paired NASC and CT-ASC PET images from one tracer ([<sup>18</sup>F]FDG) were used to train the networks, while the other two tracers were used for testing without fine-tuning (NFT-ASC). (4) The pre-trained networks of (3) were fine-tuned with two other tracers individually (FT-ASC). We trained all networks in fivefold cross-validation. The performance of all ASC methods was evaluated by qualitative and quantitative metrics using CT-ASC as the reference.</p><p><strong>Results: </strong>CZ-ASC, DL-ASC and FT-ASC showed comparable visual quality with CT-ASC for all tracers. CZ-ASC and DL-ASC resulted in a normalized mean absolute error (NMAE) of 8.51 ± 7.32% versus 7.36 ± 6.77% (p < 0.05), outperforming NASC (p < 0.0001) in [<sup>18</sup>F]FDG dataset. CZ-ASC, FT-ASC and DL-ASC led to NMAE of 6.44 ± 7.02%, 6.55 ± 5.89%, and 7.25 ± 6.33% in [<sup>18</sup>F]FAPI dataset, and NMAE of 5.53 ± 3.99%, 5.60 ± 4.02%, and 5.68 ± 4.12% in [<sup>68</sup>Ga]FAPI dataset, respectively. CZ-ASC, FT-ASC and DL-ASC were superior to NASC (p < 0.0001) and NFT-ASC (p < 0.0001) in terms of NMAE results.</p><p><strong>Conclusions: </strong>CZ-ASC, DL-ASC and FT-ASC demonstrated the feasibility of providing accurate and robust ASC for multi-tracer total-body PET, thereby reducing the radiation hazards to patients from redundant CT examinations. CZ-ASC and FT-ASC could outperform DL-ASC for cross-tracer total-body PET AC.</p>\",\"PeriodicalId\":11559,\"journal\":{\"name\":\"EJNMMI Physics\",\"volume\":\"11 1\",\"pages\":\"66\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11264498/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Physics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40658-024-00666-8\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-024-00666-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:低剂量非门控 CT 通常用于全身 PET 衰减和散射校正(ASC)。然而,基于 CT 的 ASC(CT-ASC)受限于 CT 检查的辐射剂量风险、基于 CT 的伪影传播以及 PET 和 CT 之间的潜在不匹配。我们展示了在图像域对多示踪剂全身 PET 进行直接 ASC 的可行性:本研究回顾性地纳入了uEXPLORER全身PET/CT数据集,包括[18F]FDG(52例)、[18F]FAPI(46例)和[68Ga]FAPI(60例)。我们开发了一种改进的三维条件生成对抗网络(cGAN),可从非衰减和散射校正(NASC)PET图像直接估计衰减和散射校正PET图像。使用四种训练策略验证了所提出的基于三维 cGAN 的 ASC 的可行性:(1) 将三种示踪剂的成对三维 NASC 和 CT-ASC PET 图像集中到一个中央服务器(CZ-ASC)。(2)单独使用每种示踪剂的配对 3D NASC 和 CT-ASC PET 图像(DL-ASC)。(3) 使用一种示踪剂([18F]FDG)的配对 NASC 和 CT-ASC PET 图像来训练网络,而使用另外两种示踪剂进行测试,不进行微调(NFT-ASC)。(4)用另外两种示踪剂分别对(3)中的预训练网络进行微调(FT-ASC)。我们对所有网络进行了五重交叉验证训练。以 CT-ASC 为参照,通过定性和定量指标对所有 ASC 方法的性能进行了评估:结果:对于所有示踪剂,CZ-ASC、DL-ASC 和 FT-ASC 显示出与 CT-ASC 相当的视觉质量。CZ-ASC 和 DL-ASC 的归一化平均绝对误差(NMAE)分别为 8.51 ± 7.32% 和 7.36 ± 6.77%(p 18F]FDG 数据集)。在[18F]FAPI 数据集中,CZ-ASC、FT-ASC 和 DL-ASC 的归一化平均绝对误差分别为 6.44 ± 7.02%、6.55 ± 5.89% 和 7.25 ± 6.33%;在[68Ga]FAPI 数据集中,归一化平均绝对误差分别为 5.53 ± 3.99%、5.60 ± 4.02% 和 5.68 ± 4.12%。CZ-ASC、FT-ASC 和 DL-ASC 均优于 NASC(p 结论:CZ-ASC、FT-ASC 和 DL-ASC 均优于 NASC):CZ-ASC、DL-ASC 和 FT-ASC 证明了为多示踪剂全身正电子发射计算机断层扫描提供准确、稳健的 ASC 的可行性,从而减少了多余的 CT 检查对患者造成的辐射危害。在交叉示踪剂全身 PET AC 方面,CZ-ASC 和 FT-ASC 优于 DL-ASC。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Artificial intelligence-based joint attenuation and scatter correction strategies for multi-tracer total-body PET.

Background: Low-dose ungated CT is commonly used for total-body PET attenuation and scatter correction (ASC). However, CT-based ASC (CT-ASC) is limited by radiation dose risks of CT examinations, propagation of CT-based artifacts and potential mismatches between PET and CT. We demonstrate the feasibility of direct ASC for multi-tracer total-body PET in the image domain.

Methods: Clinical uEXPLORER total-body PET/CT datasets of [18F]FDG (N = 52), [18F]FAPI (N = 46) and [68Ga]FAPI (N = 60) were retrospectively enrolled in this study. We developed an improved 3D conditional generative adversarial network (cGAN) to directly estimate attenuation and scatter-corrected PET images from non-attenuation and scatter-corrected (NASC) PET images. The feasibility of the proposed 3D cGAN-based ASC was validated using four training strategies: (1) Paired 3D NASC and CT-ASC PET images from three tracers were pooled into one centralized server (CZ-ASC). (2) Paired 3D NASC and CT-ASC PET images from each tracer were individually used (DL-ASC). (3) Paired NASC and CT-ASC PET images from one tracer ([18F]FDG) were used to train the networks, while the other two tracers were used for testing without fine-tuning (NFT-ASC). (4) The pre-trained networks of (3) were fine-tuned with two other tracers individually (FT-ASC). We trained all networks in fivefold cross-validation. The performance of all ASC methods was evaluated by qualitative and quantitative metrics using CT-ASC as the reference.

Results: CZ-ASC, DL-ASC and FT-ASC showed comparable visual quality with CT-ASC for all tracers. CZ-ASC and DL-ASC resulted in a normalized mean absolute error (NMAE) of 8.51 ± 7.32% versus 7.36 ± 6.77% (p < 0.05), outperforming NASC (p < 0.0001) in [18F]FDG dataset. CZ-ASC, FT-ASC and DL-ASC led to NMAE of 6.44 ± 7.02%, 6.55 ± 5.89%, and 7.25 ± 6.33% in [18F]FAPI dataset, and NMAE of 5.53 ± 3.99%, 5.60 ± 4.02%, and 5.68 ± 4.12% in [68Ga]FAPI dataset, respectively. CZ-ASC, FT-ASC and DL-ASC were superior to NASC (p < 0.0001) and NFT-ASC (p < 0.0001) in terms of NMAE results.

Conclusions: CZ-ASC, DL-ASC and FT-ASC demonstrated the feasibility of providing accurate and robust ASC for multi-tracer total-body PET, thereby reducing the radiation hazards to patients from redundant CT examinations. CZ-ASC and FT-ASC could outperform DL-ASC for cross-tracer total-body PET AC.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
EJNMMI Physics
EJNMMI Physics Physics and Astronomy-Radiation
CiteScore
6.70
自引率
10.00%
发文量
78
审稿时长
13 weeks
期刊介绍: EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.
期刊最新文献
CT radiation dose reduction with tin filter for localisation/characterisation level image quality in PET-CT: a phantom study. Quantitative analysis of patient motion in walk-through PET scanner and standard axial field of view pet scanner using infrared-based tracking. Comparative analysis of positron emitters for theranostic applications based on small bioconjugates highlighting 43Sc, 61Cu and 45Ti. Impact of cell geometry, cellular uptake region, and tumour morphology on 225Ac and 177Lu dose distributions in prostate cancer. Optimization and application of renal depth measurement method in the cadmium-zinc-telluride‑based SPECT/CT renal dynamic imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1