Doo Ri Kim, In Chul Nam, Hye Jin Baek, Jeong Jae Kim, Im Kyung Hwang, Jeong Sub Lee, Duk Ju Kim, Chang Lim Hyun, Sung Eun Park, Sung Wook Song
{"title":"在透视引导下对渗出性胸腔积液患者进行经皮穿刺胸膜钳活检。","authors":"Doo Ri Kim, In Chul Nam, Hye Jin Baek, Jeong Jae Kim, Im Kyung Hwang, Jeong Sub Lee, Duk Ju Kim, Chang Lim Hyun, Sung Eun Park, Sung Wook Song","doi":"10.3348/kjr.2023.0960","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to evaluate the diagnostic performance and procedural characteristics of fluoroscopy-guided percutaneous transthoracic pleural forceps biopsy (PTPFB) in patients with exudative pleural effusion.</p><p><strong>Materials and methods: </strong>Patients with exudative pleural effusion who underwent PTPFB between May 1, 2014, and February 28, 2023, were included in this retrospective study. The interval between percutaneous catheter drainage (PCD) and PTPFB, number of biopsies, procedural time, and procedure-related complications were evaluated. The sensitivity, specificity, and accuracy of diagnosing malignancy were computed for pleural cytology using PCD drainage, PTPFB, and combined PTPFB and pleural cytology.</p><p><strong>Results: </strong>Seventy-one patients, comprising 50 male and 21 female (mean age, 69.5 ± 15.3 years), were included in this study. The final diagnoses were benign lesions in 48 patients (67.6%) and malignant in 23 patients (32.4%). The overall interval between PCD and biopsy was 2.4 ± 3.7 days. The interval between PCD and biopsy in the group that underwent delayed PTPFB was 5.2 ± 3.9 days. The mean number of biopsies was 4.5 ± 1.3. The mean procedural time was 4.4 ± 2.1 minutes. Minor bleeding complications were reported in one patient (1.4%). The sensitivity, specificity, and accuracy for pleural cytology, PTPFB, and combined PTPFB and pleural cytology were 47.8% (11/23), 100% (48/48), and 83.1% (59/71), respectively; 65.2% (15/23), 100% (48/48), and 88.7% (63/71), respectively; and 78.3% (18/23), 100% (48/48), and 93.0% (66/71), respectively. The sensitivity and accuracy of cytology combined with PTPFB were significantly higher than those of cytological testing alone (<i>P</i> = 0.008 and 0.001, respectively).</p><p><strong>Conclusion: </strong>Fluoroscopy-guided PTPFB is an accurate and safe diagnostic technique for patients with exudative pleural effusion, with acceptable diagnostic performance, low complication rates, and reasonable procedural times.</p>","PeriodicalId":17881,"journal":{"name":"Korean Journal of Radiology","volume":" ","pages":"706-714"},"PeriodicalIF":4.4000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11306004/pdf/","citationCount":"0","resultStr":"{\"title\":\"Fluoroscopy-Guided Percutaneous Transthoracic Pleural Forceps Biopsy in Patients With Exudative Pleural Effusion.\",\"authors\":\"Doo Ri Kim, In Chul Nam, Hye Jin Baek, Jeong Jae Kim, Im Kyung Hwang, Jeong Sub Lee, Duk Ju Kim, Chang Lim Hyun, Sung Eun Park, Sung Wook Song\",\"doi\":\"10.3348/kjr.2023.0960\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed to evaluate the diagnostic performance and procedural characteristics of fluoroscopy-guided percutaneous transthoracic pleural forceps biopsy (PTPFB) in patients with exudative pleural effusion.</p><p><strong>Materials and methods: </strong>Patients with exudative pleural effusion who underwent PTPFB between May 1, 2014, and February 28, 2023, were included in this retrospective study. The interval between percutaneous catheter drainage (PCD) and PTPFB, number of biopsies, procedural time, and procedure-related complications were evaluated. The sensitivity, specificity, and accuracy of diagnosing malignancy were computed for pleural cytology using PCD drainage, PTPFB, and combined PTPFB and pleural cytology.</p><p><strong>Results: </strong>Seventy-one patients, comprising 50 male and 21 female (mean age, 69.5 ± 15.3 years), were included in this study. The final diagnoses were benign lesions in 48 patients (67.6%) and malignant in 23 patients (32.4%). The overall interval between PCD and biopsy was 2.4 ± 3.7 days. The interval between PCD and biopsy in the group that underwent delayed PTPFB was 5.2 ± 3.9 days. The mean number of biopsies was 4.5 ± 1.3. The mean procedural time was 4.4 ± 2.1 minutes. Minor bleeding complications were reported in one patient (1.4%). The sensitivity, specificity, and accuracy for pleural cytology, PTPFB, and combined PTPFB and pleural cytology were 47.8% (11/23), 100% (48/48), and 83.1% (59/71), respectively; 65.2% (15/23), 100% (48/48), and 88.7% (63/71), respectively; and 78.3% (18/23), 100% (48/48), and 93.0% (66/71), respectively. The sensitivity and accuracy of cytology combined with PTPFB were significantly higher than those of cytological testing alone (<i>P</i> = 0.008 and 0.001, respectively).</p><p><strong>Conclusion: </strong>Fluoroscopy-guided PTPFB is an accurate and safe diagnostic technique for patients with exudative pleural effusion, with acceptable diagnostic performance, low complication rates, and reasonable procedural times.</p>\",\"PeriodicalId\":17881,\"journal\":{\"name\":\"Korean Journal of Radiology\",\"volume\":\" \",\"pages\":\"706-714\"},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11306004/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3348/kjr.2023.0960\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3348/kjr.2023.0960","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Fluoroscopy-Guided Percutaneous Transthoracic Pleural Forceps Biopsy in Patients With Exudative Pleural Effusion.
Objective: This study aimed to evaluate the diagnostic performance and procedural characteristics of fluoroscopy-guided percutaneous transthoracic pleural forceps biopsy (PTPFB) in patients with exudative pleural effusion.
Materials and methods: Patients with exudative pleural effusion who underwent PTPFB between May 1, 2014, and February 28, 2023, were included in this retrospective study. The interval between percutaneous catheter drainage (PCD) and PTPFB, number of biopsies, procedural time, and procedure-related complications were evaluated. The sensitivity, specificity, and accuracy of diagnosing malignancy were computed for pleural cytology using PCD drainage, PTPFB, and combined PTPFB and pleural cytology.
Results: Seventy-one patients, comprising 50 male and 21 female (mean age, 69.5 ± 15.3 years), were included in this study. The final diagnoses were benign lesions in 48 patients (67.6%) and malignant in 23 patients (32.4%). The overall interval between PCD and biopsy was 2.4 ± 3.7 days. The interval between PCD and biopsy in the group that underwent delayed PTPFB was 5.2 ± 3.9 days. The mean number of biopsies was 4.5 ± 1.3. The mean procedural time was 4.4 ± 2.1 minutes. Minor bleeding complications were reported in one patient (1.4%). The sensitivity, specificity, and accuracy for pleural cytology, PTPFB, and combined PTPFB and pleural cytology were 47.8% (11/23), 100% (48/48), and 83.1% (59/71), respectively; 65.2% (15/23), 100% (48/48), and 88.7% (63/71), respectively; and 78.3% (18/23), 100% (48/48), and 93.0% (66/71), respectively. The sensitivity and accuracy of cytology combined with PTPFB were significantly higher than those of cytological testing alone (P = 0.008 and 0.001, respectively).
Conclusion: Fluoroscopy-guided PTPFB is an accurate and safe diagnostic technique for patients with exudative pleural effusion, with acceptable diagnostic performance, low complication rates, and reasonable procedural times.