{"title":"表征大功率直接芯片液体冷却数据中心排管的方法","authors":"Pardeep Shahi, Ali Heydari, Bahareh Eslami, Vahideh Radmard, Chandraprakash Hinge, Himanshu Modi, Lochan Sai Reddy Chinthaparthy, Mohammad Tradat, D. Agonafer, Jeremy Rodriguez","doi":"10.1115/1.4065948","DOIUrl":null,"url":null,"abstract":"\n Demand is growing for the dense and high-performing IT computing capacity to support artificial intelligence, deep learning, machine learning, autonomous cars, the Internet of things, etc. This led to an unprecedented growth in transistor density for high-end CPUs and GPUs, creating thermal design power (TDP) of even more than 700 watts for some of the NVIDIA existing GPUs. Cooling these high TDP chips with air cooling comes with a cost of the higher form factor of servers and noise produced by server fans close to the permissible limit. Direct-to-chip cold plate-based liquid cooling is highly efficient and becoming more reliable as the advancement in technology is taking place. Several components are used in the liquid-cooled data centers for the deployment of cold plate based direct to chip liquid cooling like cooling loops, rack manifolds, CDUs, row manifolds, quick disconnects, flow control valves, etc. Row manifolds used in liquid cooling are used to distribute secondary coolant to the rack manifolds. Characterizing these row manifolds to understand the pressure drops and flow distribution for better data center design and energy efficiency is important. In this paper, the methodology is developed to characterize the row manifolds. Water-based coolant Propylene glycol 25% was used as the coolant for the experiments and experiments were conducted at 21 °C coolant supply temperature. Two, six-port row manifolds' P-Q curves were generated, and the value of supply pressure and the flow rate were measured at each port. The results obtained from the experiments were validated by a technique called Flow Network Modeling (FNM). FNM technique uses the overall flow and thermal characteristics to represent the behavior of individual components.","PeriodicalId":15663,"journal":{"name":"Journal of Electronic Packaging","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Methodology to Characterize Row Manifolds for High Power Direct to Chip Liquid Cooling Data Centers\",\"authors\":\"Pardeep Shahi, Ali Heydari, Bahareh Eslami, Vahideh Radmard, Chandraprakash Hinge, Himanshu Modi, Lochan Sai Reddy Chinthaparthy, Mohammad Tradat, D. Agonafer, Jeremy Rodriguez\",\"doi\":\"10.1115/1.4065948\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Demand is growing for the dense and high-performing IT computing capacity to support artificial intelligence, deep learning, machine learning, autonomous cars, the Internet of things, etc. This led to an unprecedented growth in transistor density for high-end CPUs and GPUs, creating thermal design power (TDP) of even more than 700 watts for some of the NVIDIA existing GPUs. Cooling these high TDP chips with air cooling comes with a cost of the higher form factor of servers and noise produced by server fans close to the permissible limit. Direct-to-chip cold plate-based liquid cooling is highly efficient and becoming more reliable as the advancement in technology is taking place. Several components are used in the liquid-cooled data centers for the deployment of cold plate based direct to chip liquid cooling like cooling loops, rack manifolds, CDUs, row manifolds, quick disconnects, flow control valves, etc. Row manifolds used in liquid cooling are used to distribute secondary coolant to the rack manifolds. Characterizing these row manifolds to understand the pressure drops and flow distribution for better data center design and energy efficiency is important. In this paper, the methodology is developed to characterize the row manifolds. Water-based coolant Propylene glycol 25% was used as the coolant for the experiments and experiments were conducted at 21 °C coolant supply temperature. Two, six-port row manifolds' P-Q curves were generated, and the value of supply pressure and the flow rate were measured at each port. The results obtained from the experiments were validated by a technique called Flow Network Modeling (FNM). FNM technique uses the overall flow and thermal characteristics to represent the behavior of individual components.\",\"PeriodicalId\":15663,\"journal\":{\"name\":\"Journal of Electronic Packaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electronic Packaging\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4065948\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronic Packaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4065948","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

为支持人工智能、深度学习、机器学习、自动驾驶汽车、物联网等,对高密度、高性能 IT 计算能力的需求与日俱增。这导致高端 CPU 和 GPU 的晶体管密度出现了前所未有的增长,英伟达(NVIDIA)现有的一些 GPU 的热设计功率(TDP)甚至超过了 700 瓦。使用风冷冷却这些高 TDP 芯片的代价是服务器的外形尺寸较高,服务器风扇产生的噪音接近允许极限。随着技术的进步,基于冷板的直接芯片液冷技术不仅效率高,而且越来越可靠。液冷数据中心在部署基于冷板的直接芯片液冷时使用了多种组件,如冷却回路、机架歧管、CDU、行歧管、快速断开装置、流量控制阀等。液体冷却中使用的排歧管用于向机架歧管分配二次冷却剂。为了更好地设计数据中心并提高能效,必须对这些列管进行特性分析,以了解其压降和流量分布。本文开发了一种方法来表征机架歧管。实验使用 25% 的水基冷却剂丙二醇作为冷却剂,实验在 21 °C 的冷却剂供应温度下进行。生成了两个六端口排流歧管的 P-Q 曲线,并测量了每个端口的供应压力值和流量。实验结果通过一种名为 "流动网络建模(FNM)"的技术进行了验证。FNM 技术使用整体流动和热特性来表示单个组件的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Methodology to Characterize Row Manifolds for High Power Direct to Chip Liquid Cooling Data Centers
Demand is growing for the dense and high-performing IT computing capacity to support artificial intelligence, deep learning, machine learning, autonomous cars, the Internet of things, etc. This led to an unprecedented growth in transistor density for high-end CPUs and GPUs, creating thermal design power (TDP) of even more than 700 watts for some of the NVIDIA existing GPUs. Cooling these high TDP chips with air cooling comes with a cost of the higher form factor of servers and noise produced by server fans close to the permissible limit. Direct-to-chip cold plate-based liquid cooling is highly efficient and becoming more reliable as the advancement in technology is taking place. Several components are used in the liquid-cooled data centers for the deployment of cold plate based direct to chip liquid cooling like cooling loops, rack manifolds, CDUs, row manifolds, quick disconnects, flow control valves, etc. Row manifolds used in liquid cooling are used to distribute secondary coolant to the rack manifolds. Characterizing these row manifolds to understand the pressure drops and flow distribution for better data center design and energy efficiency is important. In this paper, the methodology is developed to characterize the row manifolds. Water-based coolant Propylene glycol 25% was used as the coolant for the experiments and experiments were conducted at 21 °C coolant supply temperature. Two, six-port row manifolds' P-Q curves were generated, and the value of supply pressure and the flow rate were measured at each port. The results obtained from the experiments were validated by a technique called Flow Network Modeling (FNM). FNM technique uses the overall flow and thermal characteristics to represent the behavior of individual components.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Electronic Packaging
Journal of Electronic Packaging 工程技术-工程:电子与电气
CiteScore
4.90
自引率
6.20%
发文量
44
审稿时长
3 months
期刊介绍: The Journal of Electronic Packaging publishes papers that use experimental and theoretical (analytical and computer-aided) methods, approaches, and techniques to address and solve various mechanical, materials, and reliability problems encountered in the analysis, design, manufacturing, testing, and operation of electronic and photonics components, devices, and systems. Scope: Microsystems packaging; Systems integration; Flexible electronics; Materials with nano structures and in general small scale systems.
期刊最新文献
Process Recipe and Functional Circuitry Performance On Aerosol Jet Printed Water-Based Silver Ink Incorporating Tensile Stress into Electromigration Life Prediction for Cu/SAC305/Cu Solder Joints Transient Liquid Phase Bond Acceleration Using Copper Nanowires Impact of Immersion Cooling On Thermomechanical Properties of Halogen-free Substrate Core Virtual Testbed for Economical and Reliability Analysis of Battery Thermal Management Control Strategies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1