基于智能手机的红外热成像设备在眼表热成像中的应用

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL Medical Engineering & Physics Pub Date : 2024-08-01 DOI:10.1016/j.medengphy.2024.104212
Oleg Zadorozhnyy, Taras Kustryn, Illia Nasinnyk, Alla Nevska, Olga Guzun, Andrii Korol, Nataliya Pasyechnikova
{"title":"基于智能手机的红外热成像设备在眼表热成像中的应用","authors":"Oleg Zadorozhnyy,&nbsp;Taras Kustryn,&nbsp;Illia Nasinnyk,&nbsp;Alla Nevska,&nbsp;Olga Guzun,&nbsp;Andrii Korol,&nbsp;Nataliya Pasyechnikova","doi":"10.1016/j.medengphy.2024.104212","DOIUrl":null,"url":null,"abstract":"<div><p>Infrared thermography (IRT) is a well-known imaging technique that provides a non-invasive displaying of the ocular surface temperature distribution. Currently, compact smartphone-based IRT devices, as well as special software for processing thermal images, have become available. The study aimed to determine the possible use of smartphone-based IRT devices for real-time ocular surface thermal imaging. This study involved 32 healthy individuals (64 eyes); 10 patients (10 eyes) with proliferative diabetic retinopathy (PDR) and absolute glaucoma; 10 patients (10 eyes) with PDR, who underwent vitreoretinal surgery. In all cases, simultaneous ocular surface IRT of both eyes was performed. In healthy individuals, the ocular surface temperature (OST) averaged 34.6 ± 0.8 °C and did not differ substantially between the paired eyes, in different age groups, and after pupil dilation. In our study, high intraocular pressure was accompanied by a decrease in OST in all cases. After vitreoretinal surgery in cases with confirmed subclinical inflammation, the OST was higher than the baseline and differed from that of the paired eye by more than 1.0 °C. These results highlight that smartphone-based IRT imaging could be useful for the non-invasive detection of OST asymmetry between paired eyes due to increased intraocular pressure or subclinical inflammation.</p></div>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":"130 ","pages":"Article 104212"},"PeriodicalIF":1.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of smartphone-based infrared thermography devices for ocular surface thermal imaging\",\"authors\":\"Oleg Zadorozhnyy,&nbsp;Taras Kustryn,&nbsp;Illia Nasinnyk,&nbsp;Alla Nevska,&nbsp;Olga Guzun,&nbsp;Andrii Korol,&nbsp;Nataliya Pasyechnikova\",\"doi\":\"10.1016/j.medengphy.2024.104212\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Infrared thermography (IRT) is a well-known imaging technique that provides a non-invasive displaying of the ocular surface temperature distribution. Currently, compact smartphone-based IRT devices, as well as special software for processing thermal images, have become available. The study aimed to determine the possible use of smartphone-based IRT devices for real-time ocular surface thermal imaging. This study involved 32 healthy individuals (64 eyes); 10 patients (10 eyes) with proliferative diabetic retinopathy (PDR) and absolute glaucoma; 10 patients (10 eyes) with PDR, who underwent vitreoretinal surgery. In all cases, simultaneous ocular surface IRT of both eyes was performed. In healthy individuals, the ocular surface temperature (OST) averaged 34.6 ± 0.8 °C and did not differ substantially between the paired eyes, in different age groups, and after pupil dilation. In our study, high intraocular pressure was accompanied by a decrease in OST in all cases. After vitreoretinal surgery in cases with confirmed subclinical inflammation, the OST was higher than the baseline and differed from that of the paired eye by more than 1.0 °C. These results highlight that smartphone-based IRT imaging could be useful for the non-invasive detection of OST asymmetry between paired eyes due to increased intraocular pressure or subclinical inflammation.</p></div>\",\"PeriodicalId\":49836,\"journal\":{\"name\":\"Medical Engineering & Physics\",\"volume\":\"130 \",\"pages\":\"Article 104212\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Engineering & Physics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1350453324001139\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350453324001139","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

红外热成像技术(IRT)是一种著名的成像技术,它能无创显示眼表温度分布。目前,基于智能手机的紧凑型 IRT 设备以及用于处理热图像的专用软件已经面世。本研究旨在确定基于智能手机的 IRT 设备是否可用于实时眼表热成像。这项研究涉及 32 名健康人(64 只眼);10 名增殖性糖尿病视网膜病变(PDR)和绝对性青光眼患者(10 只眼);10 名接受玻璃体视网膜手术的 PDR 患者(10 只眼)。所有病例均同时进行了双眼眼表 IRT 检查。健康人的眼表温度(OST)平均为 34.6 ± 0.8 °C,配对眼之间、不同年龄组和散瞳后的眼表温度差异不大。在我们的研究中,所有病例的高眼压都伴随着眼表温度的降低。在确诊有亚临床炎症的病例中,玻璃体视网膜手术后的 OST 比基线值高,与配对眼的 OST 相差超过 1.0 °C。这些结果突出表明,基于智能手机的 IRT 成像可用于无创检测配对眼之间因眼内压升高或亚临床炎症导致的 OST 不对称。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of smartphone-based infrared thermography devices for ocular surface thermal imaging

Infrared thermography (IRT) is a well-known imaging technique that provides a non-invasive displaying of the ocular surface temperature distribution. Currently, compact smartphone-based IRT devices, as well as special software for processing thermal images, have become available. The study aimed to determine the possible use of smartphone-based IRT devices for real-time ocular surface thermal imaging. This study involved 32 healthy individuals (64 eyes); 10 patients (10 eyes) with proliferative diabetic retinopathy (PDR) and absolute glaucoma; 10 patients (10 eyes) with PDR, who underwent vitreoretinal surgery. In all cases, simultaneous ocular surface IRT of both eyes was performed. In healthy individuals, the ocular surface temperature (OST) averaged 34.6 ± 0.8 °C and did not differ substantially between the paired eyes, in different age groups, and after pupil dilation. In our study, high intraocular pressure was accompanied by a decrease in OST in all cases. After vitreoretinal surgery in cases with confirmed subclinical inflammation, the OST was higher than the baseline and differed from that of the paired eye by more than 1.0 °C. These results highlight that smartphone-based IRT imaging could be useful for the non-invasive detection of OST asymmetry between paired eyes due to increased intraocular pressure or subclinical inflammation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
期刊最新文献
Hearing the unheard: Fundamentals of acoustic emission signals as predictors of total hip arthroplasty implant loosening Effect of excitation sequence of myocardial contraction on the mechanical response of the left ventricle Open laminectomy plus posterolateral fusion versus open laminectomy plus transforaminal lumbar interbody fusion surgical approaches for fusing degenerated L4-L5 segment: A comparative finite element study The effect of the length of chimney's protrusion on the hemodynamics of abdominal aorta stent graft after endovascular aneurysm repair Effect of plantar fascia stiffness on plantar windlass mechanism and arch: Finite element method and dual fluoroscopic imaging system verification
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1