{"title":"预测性规划血管内手术的数字孪生和人工智能技术","authors":"Jean-Noël Albertini , Lucie Derycke , Antoine Millon , Raphael Soler","doi":"10.1053/j.semvascsurg.2024.07.002","DOIUrl":null,"url":null,"abstract":"<div><p>Current planning of aortic and peripheral endovascular procedures is based largely on manual measurements performed from the 3-dimensional reconstruction of preoperative computed tomography scans. Assessment of device behavior inside patient anatomy is often difficult, and available tools, such as 3-dimensional–printed models, have several limitations. Digital twin (DT) technology has been used successfully in automotive and aerospace industries and applied recently to endovascular aortic aneurysm repair. Artificial intelligence allows the treatment of large amounts of data, and its use in medicine is increasing rapidly. The aim of this review was to present the current status of DTs combined with artificial intelligence for planning endovascular procedures. Patient-specific DTs of the aorta are generated from preoperative computed tomography and integrate aorta mechanical properties using finite element analysis. The same methodology is used to generate 3-dimensional models of aortic stent-grafts and simulate their deployment. Post processing of DT models is then performed to generate multiple parameters related to stent-graft oversizing and apposition. Machine learning algorithms allow parameters to be computed into a synthetic index to predict Type 1A endoleak risk. Other planning and sizing applications include custom-made fenestrated and branched stent-grafts for complex aneurysms. DT technology is also being investigated for planning peripheral endovascular procedures, such as carotid artery stenting. DT provides detailed information on endovascular device behavior. Analysis of DT-derived parameters with machine learning algorithms may improve accuracy in predicting complications, such as Type 1A endoleaks.</p></div>","PeriodicalId":51153,"journal":{"name":"Seminars in Vascular Surgery","volume":"37 3","pages":"Pages 306-313"},"PeriodicalIF":3.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Digital twin and artificial intelligence technologies for predictive planning of endovascular procedures\",\"authors\":\"Jean-Noël Albertini , Lucie Derycke , Antoine Millon , Raphael Soler\",\"doi\":\"10.1053/j.semvascsurg.2024.07.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Current planning of aortic and peripheral endovascular procedures is based largely on manual measurements performed from the 3-dimensional reconstruction of preoperative computed tomography scans. Assessment of device behavior inside patient anatomy is often difficult, and available tools, such as 3-dimensional–printed models, have several limitations. Digital twin (DT) technology has been used successfully in automotive and aerospace industries and applied recently to endovascular aortic aneurysm repair. Artificial intelligence allows the treatment of large amounts of data, and its use in medicine is increasing rapidly. The aim of this review was to present the current status of DTs combined with artificial intelligence for planning endovascular procedures. Patient-specific DTs of the aorta are generated from preoperative computed tomography and integrate aorta mechanical properties using finite element analysis. The same methodology is used to generate 3-dimensional models of aortic stent-grafts and simulate their deployment. Post processing of DT models is then performed to generate multiple parameters related to stent-graft oversizing and apposition. Machine learning algorithms allow parameters to be computed into a synthetic index to predict Type 1A endoleak risk. Other planning and sizing applications include custom-made fenestrated and branched stent-grafts for complex aneurysms. DT technology is also being investigated for planning peripheral endovascular procedures, such as carotid artery stenting. DT provides detailed information on endovascular device behavior. Analysis of DT-derived parameters with machine learning algorithms may improve accuracy in predicting complications, such as Type 1A endoleaks.</p></div>\",\"PeriodicalId\":51153,\"journal\":{\"name\":\"Seminars in Vascular Surgery\",\"volume\":\"37 3\",\"pages\":\"Pages 306-313\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in Vascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0895796724000425\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in Vascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0895796724000425","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Digital twin and artificial intelligence technologies for predictive planning of endovascular procedures
Current planning of aortic and peripheral endovascular procedures is based largely on manual measurements performed from the 3-dimensional reconstruction of preoperative computed tomography scans. Assessment of device behavior inside patient anatomy is often difficult, and available tools, such as 3-dimensional–printed models, have several limitations. Digital twin (DT) technology has been used successfully in automotive and aerospace industries and applied recently to endovascular aortic aneurysm repair. Artificial intelligence allows the treatment of large amounts of data, and its use in medicine is increasing rapidly. The aim of this review was to present the current status of DTs combined with artificial intelligence for planning endovascular procedures. Patient-specific DTs of the aorta are generated from preoperative computed tomography and integrate aorta mechanical properties using finite element analysis. The same methodology is used to generate 3-dimensional models of aortic stent-grafts and simulate their deployment. Post processing of DT models is then performed to generate multiple parameters related to stent-graft oversizing and apposition. Machine learning algorithms allow parameters to be computed into a synthetic index to predict Type 1A endoleak risk. Other planning and sizing applications include custom-made fenestrated and branched stent-grafts for complex aneurysms. DT technology is also being investigated for planning peripheral endovascular procedures, such as carotid artery stenting. DT provides detailed information on endovascular device behavior. Analysis of DT-derived parameters with machine learning algorithms may improve accuracy in predicting complications, such as Type 1A endoleaks.
期刊介绍:
Each issue of Seminars in Vascular Surgery examines the latest thinking on a particular clinical problem and features new diagnostic and operative techniques. The journal allows practitioners to expand their capabilities and to keep pace with the most rapidly evolving areas of surgery.