热机械老化后印刷和研磨咬合贴面的表面粗糙度、磨损和磨蚀性。

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2024-11-01 DOI:10.1016/j.prosdent.2024.07.012
Noha Morsy DDS, MSD, PhD , Mohammed El Kateb DDS, MSD, PhD , Mona Mohamed Ghoneim DDS, MSD, PhD , Ahmed A. Holiel DDS, MSD, PhD
{"title":"热机械老化后印刷和研磨咬合贴面的表面粗糙度、磨损和磨蚀性。","authors":"Noha Morsy DDS, MSD, PhD ,&nbsp;Mohammed El Kateb DDS, MSD, PhD ,&nbsp;Mona Mohamed Ghoneim DDS, MSD, PhD ,&nbsp;Ahmed A. Holiel DDS, MSD, PhD","doi":"10.1016/j.prosdent.2024.07.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Occlusal veneers are a conservative method of reestablishing vertical dimensions of occlusion (VDO) for worn teeth. A restorative material used for occlusal veneers should have a smooth surface, adequate wear resistance, and low abrasiveness to the antagonists, as total wear of occlusal veneers and their antagonists determines the stability of the reestablished VDO. Studies on roughness, wear, and abrasiveness of occlusal veneers are scarce.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to assess the surface roughness, wear, and abrasiveness of printed and milled occlusal veneers after thermomechanical aging against natural cusps and restorative materials.</div></div><div><h3>Material and methods</h3><div>Forty-eight extracted mandibular first molars were prepared for occlusal veneers and scanned with an intraoral scanner. The scans were exported to a computer-aided design program to design the occlusal veneers in 3 groups (n=16) according to the restorative material: group IP: milled lithium disilicate; group EN: milled hybrid ceramic (Vita Enamic), group VA: printed hybrid ceramic (Varseosmile Crown plus). The occlusal veneers in each group were bonded to their corresponding abutments and subjected to 250 000 mechanical cycles and a simultaneous 1000 thermal cycles in a mastication simulator. During thermomechanical aging, half of the specimens of each study group (n=8) were opposed by natural cusps (antagonist C) and the other half by antagonist cusps fabricated from the same restorative material as the occlusal veneers (antagonist R). The wear of the occlusal veneers and their antagonists was assessed with a 3-dimensional processing software program. The surface roughness of the veneers was assessed with a contact profilometer. The results were statistically analyzed with a 2-way ANOVA followed by the post hoc Tukey HSD test (α=.05).</div></div><div><h3>Results</h3><div>The 2-way ANOVA indicated a significant effect for the material and the antagonist on surface roughness, wear, and abrasiveness (<em>P</em>&lt;.05). When opposed by antagonist C, VA showed significantly higher surface roughness than IP and EN (<em>P</em>&lt;.001). VA had significantly higher surface wear followed by EN and IP (<em>P</em>&lt;.001). IP caused significantly higher wear to antagonist C than EN and VA (<em>P</em>&lt;.001). In addition, IP had significantly higher total wear (combined wear of veneers and their antagonists) followed by VA and EN (<em>P</em>&lt;.001). When opposed by antagonist R, no significant difference was found among the 3 materials for surface roughness (<em>P</em>=.08), material wear (<em>P</em>=.12), opposing wear (<em>P</em>=.11), or total wear (<em>P</em>=.11).</div></div><div><h3>Conclusions</h3><div>Both material and antagonist had a significant effect on surface roughness and occlusal stability when occlusal veneers were fabricated to restore VDO. VA had significantly more surface roughness and wear than EN and IP when opposed by natural cusps. IP abraded natural cusps significantly more than EN and VA. The 3 tested materials showed similar roughness, wear, and abrasiveness when opposed by the same material.</div></div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"132 5","pages":"Pages 984.e1-984.e7"},"PeriodicalIF":4.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Surface roughness, wear, and abrasiveness of printed and milled occlusal veneers after thermomechanical aging\",\"authors\":\"Noha Morsy DDS, MSD, PhD ,&nbsp;Mohammed El Kateb DDS, MSD, PhD ,&nbsp;Mona Mohamed Ghoneim DDS, MSD, PhD ,&nbsp;Ahmed A. Holiel DDS, MSD, PhD\",\"doi\":\"10.1016/j.prosdent.2024.07.012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Statement of problem</h3><div>Occlusal veneers are a conservative method of reestablishing vertical dimensions of occlusion (VDO) for worn teeth. A restorative material used for occlusal veneers should have a smooth surface, adequate wear resistance, and low abrasiveness to the antagonists, as total wear of occlusal veneers and their antagonists determines the stability of the reestablished VDO. Studies on roughness, wear, and abrasiveness of occlusal veneers are scarce.</div></div><div><h3>Purpose</h3><div>The purpose of this in vitro study was to assess the surface roughness, wear, and abrasiveness of printed and milled occlusal veneers after thermomechanical aging against natural cusps and restorative materials.</div></div><div><h3>Material and methods</h3><div>Forty-eight extracted mandibular first molars were prepared for occlusal veneers and scanned with an intraoral scanner. The scans were exported to a computer-aided design program to design the occlusal veneers in 3 groups (n=16) according to the restorative material: group IP: milled lithium disilicate; group EN: milled hybrid ceramic (Vita Enamic), group VA: printed hybrid ceramic (Varseosmile Crown plus). The occlusal veneers in each group were bonded to their corresponding abutments and subjected to 250 000 mechanical cycles and a simultaneous 1000 thermal cycles in a mastication simulator. During thermomechanical aging, half of the specimens of each study group (n=8) were opposed by natural cusps (antagonist C) and the other half by antagonist cusps fabricated from the same restorative material as the occlusal veneers (antagonist R). The wear of the occlusal veneers and their antagonists was assessed with a 3-dimensional processing software program. The surface roughness of the veneers was assessed with a contact profilometer. The results were statistically analyzed with a 2-way ANOVA followed by the post hoc Tukey HSD test (α=.05).</div></div><div><h3>Results</h3><div>The 2-way ANOVA indicated a significant effect for the material and the antagonist on surface roughness, wear, and abrasiveness (<em>P</em>&lt;.05). When opposed by antagonist C, VA showed significantly higher surface roughness than IP and EN (<em>P</em>&lt;.001). VA had significantly higher surface wear followed by EN and IP (<em>P</em>&lt;.001). IP caused significantly higher wear to antagonist C than EN and VA (<em>P</em>&lt;.001). In addition, IP had significantly higher total wear (combined wear of veneers and their antagonists) followed by VA and EN (<em>P</em>&lt;.001). When opposed by antagonist R, no significant difference was found among the 3 materials for surface roughness (<em>P</em>=.08), material wear (<em>P</em>=.12), opposing wear (<em>P</em>=.11), or total wear (<em>P</em>=.11).</div></div><div><h3>Conclusions</h3><div>Both material and antagonist had a significant effect on surface roughness and occlusal stability when occlusal veneers were fabricated to restore VDO. VA had significantly more surface roughness and wear than EN and IP when opposed by natural cusps. IP abraded natural cusps significantly more than EN and VA. The 3 tested materials showed similar roughness, wear, and abrasiveness when opposed by the same material.</div></div>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\"132 5\",\"pages\":\"Pages 984.e1-984.e7\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0022391324004943\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391324004943","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题陈述:咬合贴面是一种为磨损的牙齿重建咬合垂直度(VDO)的保守方法。用于咬合贴面的修复材料应具有光滑的表面、足够的耐磨性以及对拮抗剂的低磨损性,因为咬合贴面及其拮抗剂的总磨损量决定了重建的 VDO 的稳定性。关于咬合贴面的粗糙度、磨损和磨蚀性的研究很少。目的:这项体外研究的目的是评估印刷和研磨咬合贴面在热机械老化后与天然尖牙和修复材料的表面粗糙度、磨损和磨蚀性:对 48 颗拔出的下颌第一磨牙进行咬合贴面准备,并使用口内扫描仪进行扫描。将扫描结果输出到计算机辅助设计程序,根据修复材料的不同将咬合贴面分为3组(n=16):IP组:研磨二硅酸锂;EN组:研磨混合陶瓷(Vita Enamic);VA组:印刷混合陶瓷(Varseosmile Crown plus)。每组的咬合贴面都粘接在相应的基台上,并在咀嚼模拟器中进行 250 000 次机械循环和 1000 次热循环。在热机械老化过程中,每个研究组的一半试样(n=8)与天然尖牙(拮抗剂 C)相对应,另一半试样与拮抗剂尖牙相对应,拮抗剂尖牙由与咬合贴面相同的修复材料制成(拮抗剂 R)。使用三维处理软件程序评估咬合贴面及其拮抗剂的磨损情况。贴面的表面粗糙度用接触式轮廓仪进行评估。结果采用 2 方方差分析进行统计分析,然后进行事后 Tukey HSD 检验(α=.05):双向方差分析表明,材料和拮抗剂对表面粗糙度、磨损和磨蚀性(PConclusions:在制作咬合贴面修复 VDO 时,材料和拮抗剂对表面粗糙度和咬合稳定性都有显著影响。当与天然尖牙相对时,VA的表面粗糙度和磨损程度明显高于EN和IP。IP 对天然尖牙的磨损程度明显高于 EN 和 VA。当与同一种材料相对时,三种测试材料显示出相似的粗糙度、磨损度和磨蚀度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Surface roughness, wear, and abrasiveness of printed and milled occlusal veneers after thermomechanical aging

Statement of problem

Occlusal veneers are a conservative method of reestablishing vertical dimensions of occlusion (VDO) for worn teeth. A restorative material used for occlusal veneers should have a smooth surface, adequate wear resistance, and low abrasiveness to the antagonists, as total wear of occlusal veneers and their antagonists determines the stability of the reestablished VDO. Studies on roughness, wear, and abrasiveness of occlusal veneers are scarce.

Purpose

The purpose of this in vitro study was to assess the surface roughness, wear, and abrasiveness of printed and milled occlusal veneers after thermomechanical aging against natural cusps and restorative materials.

Material and methods

Forty-eight extracted mandibular first molars were prepared for occlusal veneers and scanned with an intraoral scanner. The scans were exported to a computer-aided design program to design the occlusal veneers in 3 groups (n=16) according to the restorative material: group IP: milled lithium disilicate; group EN: milled hybrid ceramic (Vita Enamic), group VA: printed hybrid ceramic (Varseosmile Crown plus). The occlusal veneers in each group were bonded to their corresponding abutments and subjected to 250 000 mechanical cycles and a simultaneous 1000 thermal cycles in a mastication simulator. During thermomechanical aging, half of the specimens of each study group (n=8) were opposed by natural cusps (antagonist C) and the other half by antagonist cusps fabricated from the same restorative material as the occlusal veneers (antagonist R). The wear of the occlusal veneers and their antagonists was assessed with a 3-dimensional processing software program. The surface roughness of the veneers was assessed with a contact profilometer. The results were statistically analyzed with a 2-way ANOVA followed by the post hoc Tukey HSD test (α=.05).

Results

The 2-way ANOVA indicated a significant effect for the material and the antagonist on surface roughness, wear, and abrasiveness (P<.05). When opposed by antagonist C, VA showed significantly higher surface roughness than IP and EN (P<.001). VA had significantly higher surface wear followed by EN and IP (P<.001). IP caused significantly higher wear to antagonist C than EN and VA (P<.001). In addition, IP had significantly higher total wear (combined wear of veneers and their antagonists) followed by VA and EN (P<.001). When opposed by antagonist R, no significant difference was found among the 3 materials for surface roughness (P=.08), material wear (P=.12), opposing wear (P=.11), or total wear (P=.11).

Conclusions

Both material and antagonist had a significant effect on surface roughness and occlusal stability when occlusal veneers were fabricated to restore VDO. VA had significantly more surface roughness and wear than EN and IP when opposed by natural cusps. IP abraded natural cusps significantly more than EN and VA. The 3 tested materials showed similar roughness, wear, and abrasiveness when opposed by the same material.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Surface properties and biofilm formation on resins for subtractively and additively manufactured fixed dental prostheses aged in artificial saliva: Effect of material type and surface finishing. Acoustic signal intensity analysis in patients with dysphonia rehabilitated with two different designs for tongue prostheses: A cross-over study. Conversion of a failing fixed implant prosthesis into an implant-retained overdenture: A clinical report. Use of a nasal obturator of computer-aided design in managing hereditary hemorrhagic telangiectasia. Mechanical and biocompatibility testing of zirconia and lithium disilicate ceramics: An in vitro study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1