基于非色散红外光谱技术的温度补偿型二氧化碳检测系统。

IF 1.3 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Review of Scientific Instruments Pub Date : 2024-08-01 DOI:10.1063/5.0203277
Ke Yu, Xiaopeng Yang, Yijie Wang, Penghui Zhang, Lei Zhang, Qiulin Tan
{"title":"基于非色散红外光谱技术的温度补偿型二氧化碳检测系统。","authors":"Ke Yu, Xiaopeng Yang, Yijie Wang, Penghui Zhang, Lei Zhang, Qiulin Tan","doi":"10.1063/5.0203277","DOIUrl":null,"url":null,"abstract":"<p><p>The concentration of carbon dioxide (CO2) is an important indicator for coal mine safety. Real-time monitoring of CO2 concentration is of great importance for taking actions in advance to avoid the occurrence of potential accidents. To address the issues of poor portability and high cost associated with existing coal mine CO2 detection equipment, this paper develops a miniaturized CO2 detection system based on non-dispersive infrared (NDIR) technology. This sensor integrates an infrared light source and a dual-channel pyroelectric detector into a reflective gas chamber, thereby achieving an extended optical path and higher system sensitivity within limited space. Meanwhile, the noise interference was greatly mitigated by using hardware and software filtering techniques. Based on principle analysis, the Lambert-Beer law was parametrically corrected, and then, a model relationship between the dual-channel voltage ratio and concentration was established. In addition, temperature compensation for zero and span values was introduced to improve the adaptability of the detection results to temperature changes. Testing results indicate that the developed detection system can realize CO2 measurement in the concentration range of 0 to 50 000 ppm within a temperature range of 0-40 °C, with a maximum detection error of less than 0.12% and a repeatability deviation of less than 1.04%. During a stability test for 12 h, the maximum concentration drift is 0.07%, indicating that the developed system meets the requirements for monitoring CO2 safety in coal mines.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A temperature-compensated CO2 detection system based on non-dispersive infrared spectral technology.\",\"authors\":\"Ke Yu, Xiaopeng Yang, Yijie Wang, Penghui Zhang, Lei Zhang, Qiulin Tan\",\"doi\":\"10.1063/5.0203277\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The concentration of carbon dioxide (CO2) is an important indicator for coal mine safety. Real-time monitoring of CO2 concentration is of great importance for taking actions in advance to avoid the occurrence of potential accidents. To address the issues of poor portability and high cost associated with existing coal mine CO2 detection equipment, this paper develops a miniaturized CO2 detection system based on non-dispersive infrared (NDIR) technology. This sensor integrates an infrared light source and a dual-channel pyroelectric detector into a reflective gas chamber, thereby achieving an extended optical path and higher system sensitivity within limited space. Meanwhile, the noise interference was greatly mitigated by using hardware and software filtering techniques. Based on principle analysis, the Lambert-Beer law was parametrically corrected, and then, a model relationship between the dual-channel voltage ratio and concentration was established. In addition, temperature compensation for zero and span values was introduced to improve the adaptability of the detection results to temperature changes. Testing results indicate that the developed detection system can realize CO2 measurement in the concentration range of 0 to 50 000 ppm within a temperature range of 0-40 °C, with a maximum detection error of less than 0.12% and a repeatability deviation of less than 1.04%. During a stability test for 12 h, the maximum concentration drift is 0.07%, indicating that the developed system meets the requirements for monitoring CO2 safety in coal mines.</p>\",\"PeriodicalId\":21111,\"journal\":{\"name\":\"Review of Scientific Instruments\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Review of Scientific Instruments\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0203277\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0203277","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

二氧化碳(CO2)浓度是煤矿安全的一个重要指标。实时监测二氧化碳浓度对于提前采取措施避免潜在事故的发生具有重要意义。针对现有煤矿二氧化碳检测设备便携性差、成本高等问题,本文开发了一种基于非色散红外(NDIR)技术的微型二氧化碳检测系统。该传感器将红外光源和双通道热释电探测器集成到一个反射气室中,从而在有限的空间内实现了更长的光路和更高的系统灵敏度。同时,通过使用硬件和软件滤波技术,大大降低了噪声干扰。基于原理分析,对朗伯-比尔定律进行了参数修正,然后建立了双通道电压比与浓度之间的模型关系。此外,还引入了零值和跨度值的温度补偿,以提高检测结果对温度变化的适应性。测试结果表明,所开发的检测系统可在 0-40 °C 的温度范围内实现 0 至 50 000 ppm 浓度范围内的二氧化碳测量,最大检测误差小于 0.12%,重复性偏差小于 1.04%。在 12 小时的稳定性测试中,最大浓度漂移为 0.07%,表明所开发的系统符合煤矿二氧化碳安全监测的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A temperature-compensated CO2 detection system based on non-dispersive infrared spectral technology.

The concentration of carbon dioxide (CO2) is an important indicator for coal mine safety. Real-time monitoring of CO2 concentration is of great importance for taking actions in advance to avoid the occurrence of potential accidents. To address the issues of poor portability and high cost associated with existing coal mine CO2 detection equipment, this paper develops a miniaturized CO2 detection system based on non-dispersive infrared (NDIR) technology. This sensor integrates an infrared light source and a dual-channel pyroelectric detector into a reflective gas chamber, thereby achieving an extended optical path and higher system sensitivity within limited space. Meanwhile, the noise interference was greatly mitigated by using hardware and software filtering techniques. Based on principle analysis, the Lambert-Beer law was parametrically corrected, and then, a model relationship between the dual-channel voltage ratio and concentration was established. In addition, temperature compensation for zero and span values was introduced to improve the adaptability of the detection results to temperature changes. Testing results indicate that the developed detection system can realize CO2 measurement in the concentration range of 0 to 50 000 ppm within a temperature range of 0-40 °C, with a maximum detection error of less than 0.12% and a repeatability deviation of less than 1.04%. During a stability test for 12 h, the maximum concentration drift is 0.07%, indicating that the developed system meets the requirements for monitoring CO2 safety in coal mines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
期刊最新文献
A liquid metal diffusion measurement technique integrating the x-ray radiography and multi-slice sliding cell. Classification of the L-, H-mode, and plasma-free state: Convolutional neural networks and variational autoencoders on the edge reflectometer for KSTAR. Design of a gamma threshold detector based on the bubble chamber for high-flux gamma beams. Development and construction of a cost-effective non-contact instrument for measuring the dielectric constant of liquids. Development of a compact bolometer camera concept for investigation of radiation asymmetries at Wendelstein 7-X.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1