使用不同采样装置对干血斑中磷脂酰乙醇含量进行实验室间比较。

IF 2.6 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS Drug Testing and Analysis Pub Date : 2024-08-16 DOI:10.1002/dta.3784
Matthias Bantle, Frederike Stöth, Wolfgang Weinmann, Marc Luginbühl
{"title":"使用不同采样装置对干血斑中磷脂酰乙醇含量进行实验室间比较。","authors":"Matthias Bantle, Frederike Stöth, Wolfgang Weinmann, Marc Luginbühl","doi":"10.1002/dta.3784","DOIUrl":null,"url":null,"abstract":"<p><p>Phosphatidylethanol (PEth) has become an important marker to assess drinking behaviour and monitor abstinence. Despite its increasing use, knowledge on robustness and standardization and comparability of methods and results are still limited. In 2022, the first international consensus for the use of PEth and its interpretation was published. To establish an experience-based foundation for further harmonization, three rounds of interlaboratory comparison using microsamples were conducted. Participating laboratories sent their sampling devices to the laboratory of Forensic Toxicology at the University of Bern, where for each round, four different authentic blood samples were applied to the devices and sent back. The PEth 16:0/18:1 target concentrations covered a range between 16 and 474 ng/mL (0.023 and 0.676 μmol/L, respectively) and included sample concentrations close to the decision limits of 20 and 200 ng/mL (0.025 and 0.28 μmol/L, respectively). Evaluation of the results based on guidelines by Horwitz and the Society of Toxicological and Forensic Chemistry (GTFCh) showed that 73% of all participating laboratories quantified and reported all samples (N = 4 for each round) within the acceptable limits. More than 90% quantified and reported at least one sample within the acceptable limits.</p>","PeriodicalId":160,"journal":{"name":"Drug Testing and Analysis","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interlaboratory comparison of phosphatidylethanol in dried blood spots using different sampling devices.\",\"authors\":\"Matthias Bantle, Frederike Stöth, Wolfgang Weinmann, Marc Luginbühl\",\"doi\":\"10.1002/dta.3784\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Phosphatidylethanol (PEth) has become an important marker to assess drinking behaviour and monitor abstinence. Despite its increasing use, knowledge on robustness and standardization and comparability of methods and results are still limited. In 2022, the first international consensus for the use of PEth and its interpretation was published. To establish an experience-based foundation for further harmonization, three rounds of interlaboratory comparison using microsamples were conducted. Participating laboratories sent their sampling devices to the laboratory of Forensic Toxicology at the University of Bern, where for each round, four different authentic blood samples were applied to the devices and sent back. The PEth 16:0/18:1 target concentrations covered a range between 16 and 474 ng/mL (0.023 and 0.676 μmol/L, respectively) and included sample concentrations close to the decision limits of 20 and 200 ng/mL (0.025 and 0.28 μmol/L, respectively). Evaluation of the results based on guidelines by Horwitz and the Society of Toxicological and Forensic Chemistry (GTFCh) showed that 73% of all participating laboratories quantified and reported all samples (N = 4 for each round) within the acceptable limits. More than 90% quantified and reported at least one sample within the acceptable limits.</p>\",\"PeriodicalId\":160,\"journal\":{\"name\":\"Drug Testing and Analysis\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Drug Testing and Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/dta.3784\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Testing and Analysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/dta.3784","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

磷脂酰乙醇(PEth)已成为评估饮酒行为和监测戒酒情况的重要指标。尽管其应用日益广泛,但对其稳健性、标准化以及方法和结果的可比性的了解仍然有限。2022 年,国际上首次就 PEth 的使用及其解释达成共识。为了为进一步统一奠定经验基础,使用微量样本进行了三轮实验室间比对。参与比对的实验室将其采样设备送到伯尔尼大学的法医毒理学实验室,每轮比对都在采样设备上采集四份不同的真实血样,然后寄回。PEth 16:0/18:1 的目标浓度范围为 16 至 474 纳克/毫升(分别为 0.023 和 0.676 μmol/L),其中包括接近 20 和 200 纳克/毫升(分别为 0.025 和 0.28 μmol/L)判定限的样本浓度。根据 Horwitz 和毒理学与法医化学学会 (GTFCh) 的指南对结果进行的评估显示,73% 的参与实验室对所有样本(每轮 4 个样本)的定量和报告均在可接受范围内。超过 90% 的实验室至少有一个样本的量化和报告结果在可接受范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Interlaboratory comparison of phosphatidylethanol in dried blood spots using different sampling devices.

Phosphatidylethanol (PEth) has become an important marker to assess drinking behaviour and monitor abstinence. Despite its increasing use, knowledge on robustness and standardization and comparability of methods and results are still limited. In 2022, the first international consensus for the use of PEth and its interpretation was published. To establish an experience-based foundation for further harmonization, three rounds of interlaboratory comparison using microsamples were conducted. Participating laboratories sent their sampling devices to the laboratory of Forensic Toxicology at the University of Bern, where for each round, four different authentic blood samples were applied to the devices and sent back. The PEth 16:0/18:1 target concentrations covered a range between 16 and 474 ng/mL (0.023 and 0.676 μmol/L, respectively) and included sample concentrations close to the decision limits of 20 and 200 ng/mL (0.025 and 0.28 μmol/L, respectively). Evaluation of the results based on guidelines by Horwitz and the Society of Toxicological and Forensic Chemistry (GTFCh) showed that 73% of all participating laboratories quantified and reported all samples (N = 4 for each round) within the acceptable limits. More than 90% quantified and reported at least one sample within the acceptable limits.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Drug Testing and Analysis
Drug Testing and Analysis BIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
5.90
自引率
24.10%
发文量
191
审稿时长
2.3 months
期刊介绍: As the incidence of drugs escalates in 21st century living, their detection and analysis have become increasingly important. Sport, the workplace, crime investigation, homeland security, the pharmaceutical industry and the environment are just some of the high profile arenas in which analytical testing has provided an important investigative tool for uncovering the presence of extraneous substances. In addition to the usual publishing fare of primary research articles, case reports and letters, Drug Testing and Analysis offers a unique combination of; ‘How to’ material such as ‘Tutorials’ and ‘Reviews’, Speculative pieces (‘Commentaries’ and ‘Perspectives'', providing a broader scientific and social context to the aspects of analytical testing), ‘Annual banned substance reviews’ (delivering a critical evaluation of the methods used in the characterization of established and newly outlawed compounds). Rather than focus on the application of a single technique, Drug Testing and Analysis employs a unique multidisciplinary approach to the field of controversial compound determination. Papers discussing chromatography, mass spectrometry, immunological approaches, 1D/2D gel electrophoresis, to name just a few select methods, are welcomed where their application is related to any of the six key topics listed below.
期刊最新文献
Determination of Hormonal Growth Promotants in Beef Using Liquid Chromatography-Tandem Mass Spectrometry. Detecting EPO in Microvolumetric Capillary Serum Shipped at Ambient Temperature for Antidoping Testing. Investigation Into the Equine Metabolism of Phosphodiesterase-4 Inhibitor Roflumilast for Potential Doping Control. UHPLC-QTOFMS Urine Drug Screening With Dilute-and-Shoot Sample Preparation and Vacuum-Insulated Probe-Heated Electrospray Ionization. Cover Picture
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1