{"title":"在未增强低剂量 CT 中自动检测肾积水的放射组学特征","authors":"","doi":"10.1016/j.ejrad.2024.111677","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To investigate the diagnostic performance of an automatic pipeline for detection of hydronephrosis on kidney's parenchyma on unenhanced low-dose CT of the abdomen.</p></div><div><h3>Methods</h3><p>This retrospective study included 95 patients with confirmed unilateral hydronephrosis in an unenhanced low-dose CT of the abdomen. Data were split into training (n = 67) and test (n = 28) cohorts. Both kidneys for each case were included in further analyses, whereas the kidney without hydronephrosis was used as control. Using the training cohort, we developed a pipeline consisting of a deep-learning model for automatic segmentation (a Convolutional Neural Network based on nnU-Net architecture) of the kidney's parenchyma and a radiomics classifier to detect hydronephrosis. The models were assessed using standard classification metrics, such as area under the ROC curve (AUC), sensitivity and specificity, as well as semantic segmentation metrics, including Dice coefficient and Jaccard index.</p></div><div><h3>Results</h3><p>Using manual segmentation of the kidney’s parenchyma, hydronephrosis can be detected with an AUC of 0.84, a sensitivity of 75% and a specificity of 82%, a PPV of 81% and a NPV of 77%. Automatic kidney segmentation achieved a mean Dice score of 0.87 and 0.91 for the right and left kidney, respectively. Additionally, automatic segmentation achieved an AUC of 0.83, a sensitivity of 86%, specificity of 64%, PPV of 71%, and NPV of 82%.</p></div><div><h3>Conclusion</h3><p>Our proposed radiomics signature using automatic kidney's parenchyma segmentation allows for accurate hydronephrosis detection on unenhanced low-dose CT scans of the abdomen independently of widened renal pelvis. This method could be used in clinical routine to highlight hydronephrosis to radiologists as well as clinicians, especially in patients with concurrent parapelvic cysts and might reduce time and costs associated with diagnosing hydronephrosis.</p></div>","PeriodicalId":12063,"journal":{"name":"European Journal of Radiology","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0720048X24003930/pdfft?md5=869f41be2f98299ecf791bde33661974&pid=1-s2.0-S0720048X24003930-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Radiomics signature for automatic hydronephrosis detection in unenhanced Low-Dose CT\",\"authors\":\"\",\"doi\":\"10.1016/j.ejrad.2024.111677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>To investigate the diagnostic performance of an automatic pipeline for detection of hydronephrosis on kidney's parenchyma on unenhanced low-dose CT of the abdomen.</p></div><div><h3>Methods</h3><p>This retrospective study included 95 patients with confirmed unilateral hydronephrosis in an unenhanced low-dose CT of the abdomen. Data were split into training (n = 67) and test (n = 28) cohorts. Both kidneys for each case were included in further analyses, whereas the kidney without hydronephrosis was used as control. Using the training cohort, we developed a pipeline consisting of a deep-learning model for automatic segmentation (a Convolutional Neural Network based on nnU-Net architecture) of the kidney's parenchyma and a radiomics classifier to detect hydronephrosis. The models were assessed using standard classification metrics, such as area under the ROC curve (AUC), sensitivity and specificity, as well as semantic segmentation metrics, including Dice coefficient and Jaccard index.</p></div><div><h3>Results</h3><p>Using manual segmentation of the kidney’s parenchyma, hydronephrosis can be detected with an AUC of 0.84, a sensitivity of 75% and a specificity of 82%, a PPV of 81% and a NPV of 77%. Automatic kidney segmentation achieved a mean Dice score of 0.87 and 0.91 for the right and left kidney, respectively. Additionally, automatic segmentation achieved an AUC of 0.83, a sensitivity of 86%, specificity of 64%, PPV of 71%, and NPV of 82%.</p></div><div><h3>Conclusion</h3><p>Our proposed radiomics signature using automatic kidney's parenchyma segmentation allows for accurate hydronephrosis detection on unenhanced low-dose CT scans of the abdomen independently of widened renal pelvis. This method could be used in clinical routine to highlight hydronephrosis to radiologists as well as clinicians, especially in patients with concurrent parapelvic cysts and might reduce time and costs associated with diagnosing hydronephrosis.</p></div>\",\"PeriodicalId\":12063,\"journal\":{\"name\":\"European Journal of Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0720048X24003930/pdfft?md5=869f41be2f98299ecf791bde33661974&pid=1-s2.0-S0720048X24003930-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0720048X24003930\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0720048X24003930","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Radiomics signature for automatic hydronephrosis detection in unenhanced Low-Dose CT
Purpose
To investigate the diagnostic performance of an automatic pipeline for detection of hydronephrosis on kidney's parenchyma on unenhanced low-dose CT of the abdomen.
Methods
This retrospective study included 95 patients with confirmed unilateral hydronephrosis in an unenhanced low-dose CT of the abdomen. Data were split into training (n = 67) and test (n = 28) cohorts. Both kidneys for each case were included in further analyses, whereas the kidney without hydronephrosis was used as control. Using the training cohort, we developed a pipeline consisting of a deep-learning model for automatic segmentation (a Convolutional Neural Network based on nnU-Net architecture) of the kidney's parenchyma and a radiomics classifier to detect hydronephrosis. The models were assessed using standard classification metrics, such as area under the ROC curve (AUC), sensitivity and specificity, as well as semantic segmentation metrics, including Dice coefficient and Jaccard index.
Results
Using manual segmentation of the kidney’s parenchyma, hydronephrosis can be detected with an AUC of 0.84, a sensitivity of 75% and a specificity of 82%, a PPV of 81% and a NPV of 77%. Automatic kidney segmentation achieved a mean Dice score of 0.87 and 0.91 for the right and left kidney, respectively. Additionally, automatic segmentation achieved an AUC of 0.83, a sensitivity of 86%, specificity of 64%, PPV of 71%, and NPV of 82%.
Conclusion
Our proposed radiomics signature using automatic kidney's parenchyma segmentation allows for accurate hydronephrosis detection on unenhanced low-dose CT scans of the abdomen independently of widened renal pelvis. This method could be used in clinical routine to highlight hydronephrosis to radiologists as well as clinicians, especially in patients with concurrent parapelvic cysts and might reduce time and costs associated with diagnosing hydronephrosis.
期刊介绍:
European Journal of Radiology is an international journal which aims to communicate to its readers, state-of-the-art information on imaging developments in the form of high quality original research articles and timely reviews on current developments in the field.
Its audience includes clinicians at all levels of training including radiology trainees, newly qualified imaging specialists and the experienced radiologist. Its aim is to inform efficient, appropriate and evidence-based imaging practice to the benefit of patients worldwide.