Antoine Venault, Yi-Ling Wu, Wen Xin Yen, Yung Chang
{"title":"用于赋予绿色 VIPS 膜防污性能的绿色块体改性剂","authors":"Antoine Venault, Yi-Ling Wu, Wen Xin Yen, Yung Chang","doi":"10.1016/j.jtice.2024.105731","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Membrane preparation and membrane modification processes have long involved the use of toxic solvents. The present work proposes to only use envrionmentally-friendly solvents for both the fabrication and the surface modification of hydrophobic microfiltration membranes. In addition, coating processes for membrane modification are essentially surface modification processes. However, spray-coating may be a suitable method for both surface and bulk modification.</p></div><div><h3>Methods</h3><p>After dissolving poly(vinylidene fluoride) in dimethylsulfoxide, membranes were formed by the vapor-induced phase separation process, and then modified using an aqeous solution of an amphiphilic copolymer containing poly(ethylene glycol) methyl ether methacrylate units. Then, a variety of physicochemical techniques were employed to characterize the membrane structure and prove the effectiveness of the surface/bulk modification. Antifouling tests in static and dynamic conditions were conducted.</p></div><div><h3>Significant findings</h3><p>It is possible to reduce the water contact angle of the top surface of the membrane from 135° to 0° and that of the bottom surface from 126° to 0° within <10 s, indicating successful hydrophilization of the membrane on the one hand, and top-to-bottom modification, despite solely exposing the top surface to the spray, on the other hand. This conclusion was confirmed by deidcated surface chemistry analyses. Besides, the membranes maintained their original highly porous and symmetric structure with light effects on surface porosity and pore size following the spray-coating process. The drasting improvement of hydrophilicity resulted in effective mitigation of fibrinogen adsorption (reduced by 85 %) and <em>Escherichia coli</em> adhesion (reduced by 86 %). Fouling during cyclic filtration involving a bacterial suspension was also effectively reduced with a flux recovery ratio of 53 % (against 37 % for a commercial hydrophilic membrane) and an irreversible flux decline ratio of 47 % (against 63 % for a commercial hydrophilic membrane) in the conditions of the test.</p></div>","PeriodicalId":381,"journal":{"name":"Journal of the Taiwan Institute of Chemical Engineers","volume":"165 ","pages":"Article 105731"},"PeriodicalIF":5.5000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A green bulk modification for imparting a green VIPS membrane with antifouling properties\",\"authors\":\"Antoine Venault, Yi-Ling Wu, Wen Xin Yen, Yung Chang\",\"doi\":\"10.1016/j.jtice.2024.105731\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Membrane preparation and membrane modification processes have long involved the use of toxic solvents. The present work proposes to only use envrionmentally-friendly solvents for both the fabrication and the surface modification of hydrophobic microfiltration membranes. In addition, coating processes for membrane modification are essentially surface modification processes. However, spray-coating may be a suitable method for both surface and bulk modification.</p></div><div><h3>Methods</h3><p>After dissolving poly(vinylidene fluoride) in dimethylsulfoxide, membranes were formed by the vapor-induced phase separation process, and then modified using an aqeous solution of an amphiphilic copolymer containing poly(ethylene glycol) methyl ether methacrylate units. Then, a variety of physicochemical techniques were employed to characterize the membrane structure and prove the effectiveness of the surface/bulk modification. Antifouling tests in static and dynamic conditions were conducted.</p></div><div><h3>Significant findings</h3><p>It is possible to reduce the water contact angle of the top surface of the membrane from 135° to 0° and that of the bottom surface from 126° to 0° within <10 s, indicating successful hydrophilization of the membrane on the one hand, and top-to-bottom modification, despite solely exposing the top surface to the spray, on the other hand. This conclusion was confirmed by deidcated surface chemistry analyses. Besides, the membranes maintained their original highly porous and symmetric structure with light effects on surface porosity and pore size following the spray-coating process. The drasting improvement of hydrophilicity resulted in effective mitigation of fibrinogen adsorption (reduced by 85 %) and <em>Escherichia coli</em> adhesion (reduced by 86 %). Fouling during cyclic filtration involving a bacterial suspension was also effectively reduced with a flux recovery ratio of 53 % (against 37 % for a commercial hydrophilic membrane) and an irreversible flux decline ratio of 47 % (against 63 % for a commercial hydrophilic membrane) in the conditions of the test.</p></div>\",\"PeriodicalId\":381,\"journal\":{\"name\":\"Journal of the Taiwan Institute of Chemical Engineers\",\"volume\":\"165 \",\"pages\":\"Article 105731\"},\"PeriodicalIF\":5.5000,\"publicationDate\":\"2024-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Taiwan Institute of Chemical Engineers\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1876107024003894\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Taiwan Institute of Chemical Engineers","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1876107024003894","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
A green bulk modification for imparting a green VIPS membrane with antifouling properties
Background
Membrane preparation and membrane modification processes have long involved the use of toxic solvents. The present work proposes to only use envrionmentally-friendly solvents for both the fabrication and the surface modification of hydrophobic microfiltration membranes. In addition, coating processes for membrane modification are essentially surface modification processes. However, spray-coating may be a suitable method for both surface and bulk modification.
Methods
After dissolving poly(vinylidene fluoride) in dimethylsulfoxide, membranes were formed by the vapor-induced phase separation process, and then modified using an aqeous solution of an amphiphilic copolymer containing poly(ethylene glycol) methyl ether methacrylate units. Then, a variety of physicochemical techniques were employed to characterize the membrane structure and prove the effectiveness of the surface/bulk modification. Antifouling tests in static and dynamic conditions were conducted.
Significant findings
It is possible to reduce the water contact angle of the top surface of the membrane from 135° to 0° and that of the bottom surface from 126° to 0° within <10 s, indicating successful hydrophilization of the membrane on the one hand, and top-to-bottom modification, despite solely exposing the top surface to the spray, on the other hand. This conclusion was confirmed by deidcated surface chemistry analyses. Besides, the membranes maintained their original highly porous and symmetric structure with light effects on surface porosity and pore size following the spray-coating process. The drasting improvement of hydrophilicity resulted in effective mitigation of fibrinogen adsorption (reduced by 85 %) and Escherichia coli adhesion (reduced by 86 %). Fouling during cyclic filtration involving a bacterial suspension was also effectively reduced with a flux recovery ratio of 53 % (against 37 % for a commercial hydrophilic membrane) and an irreversible flux decline ratio of 47 % (against 63 % for a commercial hydrophilic membrane) in the conditions of the test.
期刊介绍:
Journal of the Taiwan Institute of Chemical Engineers (formerly known as Journal of the Chinese Institute of Chemical Engineers) publishes original works, from fundamental principles to practical applications, in the broad field of chemical engineering with special focus on three aspects: Chemical and Biomolecular Science and Technology, Energy and Environmental Science and Technology, and Materials Science and Technology. Authors should choose for their manuscript an appropriate aspect section and a few related classifications when submitting to the journal online.