{"title":"在法洛氏四联症心肺运动测试中量化氧脉搏曲线特征的新技术","authors":"","doi":"10.1016/j.ijcchd.2024.100539","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Cardiopulmonary exercise testing (CPET) is used in evaluation of repaired tetralogy of Fallot (rTOF), particularly for pulmonary valve replacement need. Oxygen pulse (O<sub>2</sub>P) is the CPET surrogate for stroke volume and peripheral oxygen extraction.</p></div><div><h3>Objectives</h3><p>This study assessed O<sub>2</sub>P curve properties against non-invasive cardiac output monitoring (NICOM) and clinical testing.</p></div><div><h3>Methods</h3><p>This cross-sectional study included 44 rTOF patients and 10 controls. Three new evaluations for O<sub>2</sub>P curve analysis during CPET were developed. Best fit early and late regression slopes of the O<sub>2</sub>P curve were used to calculate: 1) the early to late ratio, or “O<sub>2</sub> pulse response ratio” (O<sub>2</sub>PRR); 2) the portion of exercise until slope inflection, or “flattening fraction” (FF); 3) the area under the O<sub>2</sub>P response curve, or “O<sub>2</sub>P curve area”.</p></div><div><h3>Results</h3><p>rTOF patients (median age 35.2 (27.6–39.4); 61% female) had a lower VO<sub>2</sub> max (23.4 vs 45.6 ml/kg/min; p < 0.001) and O<sub>2</sub>P max (11.5 vs 19.1 ml/beat; p < 0.001) compared to controls. Those with a FF occurring <50% through exercise had a lower peak cardiac index and stroke volume, but not VO<sub>2</sub> max, compared to those >50%. FF and O<sub>2</sub>P curve area significantly correlated with peak cardiac index, stroke volume, left and right ventricular ejection fraction, and right ventricular systolic pressure.</p></div><div><h3>Conclusion</h3><p>CPET remains an integral part in the evaluation of rTOF. We introduce three non-invasive methods to assess exercise hemodynamics using the O<sub>2</sub>P curve data. These evaluations demonstrated significant correlations with stroke volume, cardiac output, and right ventricular pressure.</p></div>","PeriodicalId":73429,"journal":{"name":"International journal of cardiology. Congenital heart disease","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S266666852400048X/pdfft?md5=7b84ac15bd2ec21c11b5fb7d8a372d86&pid=1-s2.0-S266666852400048X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Novel techniques for quantifying oxygen pulse curve characteristics during cardiopulmonary exercise testing in tetralogy of fallot\",\"authors\":\"\",\"doi\":\"10.1016/j.ijcchd.2024.100539\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Cardiopulmonary exercise testing (CPET) is used in evaluation of repaired tetralogy of Fallot (rTOF), particularly for pulmonary valve replacement need. Oxygen pulse (O<sub>2</sub>P) is the CPET surrogate for stroke volume and peripheral oxygen extraction.</p></div><div><h3>Objectives</h3><p>This study assessed O<sub>2</sub>P curve properties against non-invasive cardiac output monitoring (NICOM) and clinical testing.</p></div><div><h3>Methods</h3><p>This cross-sectional study included 44 rTOF patients and 10 controls. Three new evaluations for O<sub>2</sub>P curve analysis during CPET were developed. Best fit early and late regression slopes of the O<sub>2</sub>P curve were used to calculate: 1) the early to late ratio, or “O<sub>2</sub> pulse response ratio” (O<sub>2</sub>PRR); 2) the portion of exercise until slope inflection, or “flattening fraction” (FF); 3) the area under the O<sub>2</sub>P response curve, or “O<sub>2</sub>P curve area”.</p></div><div><h3>Results</h3><p>rTOF patients (median age 35.2 (27.6–39.4); 61% female) had a lower VO<sub>2</sub> max (23.4 vs 45.6 ml/kg/min; p < 0.001) and O<sub>2</sub>P max (11.5 vs 19.1 ml/beat; p < 0.001) compared to controls. Those with a FF occurring <50% through exercise had a lower peak cardiac index and stroke volume, but not VO<sub>2</sub> max, compared to those >50%. FF and O<sub>2</sub>P curve area significantly correlated with peak cardiac index, stroke volume, left and right ventricular ejection fraction, and right ventricular systolic pressure.</p></div><div><h3>Conclusion</h3><p>CPET remains an integral part in the evaluation of rTOF. We introduce three non-invasive methods to assess exercise hemodynamics using the O<sub>2</sub>P curve data. These evaluations demonstrated significant correlations with stroke volume, cardiac output, and right ventricular pressure.</p></div>\",\"PeriodicalId\":73429,\"journal\":{\"name\":\"International journal of cardiology. Congenital heart disease\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S266666852400048X/pdfft?md5=7b84ac15bd2ec21c11b5fb7d8a372d86&pid=1-s2.0-S266666852400048X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of cardiology. Congenital heart disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S266666852400048X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiology. Congenital heart disease","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266666852400048X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Novel techniques for quantifying oxygen pulse curve characteristics during cardiopulmonary exercise testing in tetralogy of fallot
Background
Cardiopulmonary exercise testing (CPET) is used in evaluation of repaired tetralogy of Fallot (rTOF), particularly for pulmonary valve replacement need. Oxygen pulse (O2P) is the CPET surrogate for stroke volume and peripheral oxygen extraction.
Objectives
This study assessed O2P curve properties against non-invasive cardiac output monitoring (NICOM) and clinical testing.
Methods
This cross-sectional study included 44 rTOF patients and 10 controls. Three new evaluations for O2P curve analysis during CPET were developed. Best fit early and late regression slopes of the O2P curve were used to calculate: 1) the early to late ratio, or “O2 pulse response ratio” (O2PRR); 2) the portion of exercise until slope inflection, or “flattening fraction” (FF); 3) the area under the O2P response curve, or “O2P curve area”.
Results
rTOF patients (median age 35.2 (27.6–39.4); 61% female) had a lower VO2 max (23.4 vs 45.6 ml/kg/min; p < 0.001) and O2P max (11.5 vs 19.1 ml/beat; p < 0.001) compared to controls. Those with a FF occurring <50% through exercise had a lower peak cardiac index and stroke volume, but not VO2 max, compared to those >50%. FF and O2P curve area significantly correlated with peak cardiac index, stroke volume, left and right ventricular ejection fraction, and right ventricular systolic pressure.
Conclusion