{"title":"开发一种 UPLC-MS/MS 方法,用于检测和量化米拉贝琼中的 N-亚硝基米拉贝琼。","authors":"Ravi Uppala, Rakesh Chandrakant Prabhu, Arthanareeswari Maruthapillai, Bandaru Venkatasubbaiah, Gopal Chandru Senadi, Sundaramurthy Devikala","doi":"10.1002/rcm.9911","DOIUrl":null,"url":null,"abstract":"<p>In the mirabegron (MIR) synthesis, the N-nitroso mirabegron (NNM) is obtained during synthetic process of MIR; water is being used in reaction under acidic condition. Nitrite source is from water, and secondary amine source is from MIR as it has secondary amine; NNM is generated as an impurity during the synthesis of MIR. The presence of NNM in MIR could potentially affect its effectiveness. The purpose of this study was to establish a Ultra-performance liquid chromatography-mass spectrometry/mass spectrometry (UPLC-MS/MS) methodology to identify NNM in MIR samples. The method for NNM analysis was developed on Acquity HSS T3 (100*2.1) mm 1.8 μm column with gradient elution using mobile phase consisted of 0.1% formic acid in water (mobile phase A) and 0.1% formic acid in methanol (mobile phase B). Mass spectrometer with electrospray ionization operated in the MRM mode was used in the analysis of NNM (m/ z 426.20 → 170.00). The UPLC-MS/MS methodology proposed showed a good linearity (0.02 to 0.72 ppm), good system precision (RSD = 0.57%), good method precision (RSD = 0.87%), acceptable accuracy (94.5–116.5%), low detection limit (0.006 ppm) and low quantification limit (0.02 ppm) for NNM. The UPLC-MS/MS methodology proposed can be utilized to assess the quality of MIR sample for the presence of NNM impurity.</p>","PeriodicalId":225,"journal":{"name":"Rapid Communications in Mass Spectrometry","volume":"38 22","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of an UPLC-MS/MS approach to detect and quantify N-nitroso mirabegron in mirabegron\",\"authors\":\"Ravi Uppala, Rakesh Chandrakant Prabhu, Arthanareeswari Maruthapillai, Bandaru Venkatasubbaiah, Gopal Chandru Senadi, Sundaramurthy Devikala\",\"doi\":\"10.1002/rcm.9911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In the mirabegron (MIR) synthesis, the N-nitroso mirabegron (NNM) is obtained during synthetic process of MIR; water is being used in reaction under acidic condition. Nitrite source is from water, and secondary amine source is from MIR as it has secondary amine; NNM is generated as an impurity during the synthesis of MIR. The presence of NNM in MIR could potentially affect its effectiveness. The purpose of this study was to establish a Ultra-performance liquid chromatography-mass spectrometry/mass spectrometry (UPLC-MS/MS) methodology to identify NNM in MIR samples. The method for NNM analysis was developed on Acquity HSS T3 (100*2.1) mm 1.8 μm column with gradient elution using mobile phase consisted of 0.1% formic acid in water (mobile phase A) and 0.1% formic acid in methanol (mobile phase B). Mass spectrometer with electrospray ionization operated in the MRM mode was used in the analysis of NNM (m/ z 426.20 → 170.00). The UPLC-MS/MS methodology proposed showed a good linearity (0.02 to 0.72 ppm), good system precision (RSD = 0.57%), good method precision (RSD = 0.87%), acceptable accuracy (94.5–116.5%), low detection limit (0.006 ppm) and low quantification limit (0.02 ppm) for NNM. The UPLC-MS/MS methodology proposed can be utilized to assess the quality of MIR sample for the presence of NNM impurity.</p>\",\"PeriodicalId\":225,\"journal\":{\"name\":\"Rapid Communications in Mass Spectrometry\",\"volume\":\"38 22\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rapid Communications in Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9911\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rapid Communications in Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcm.9911","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
摘要
在米拉贝琼(MIR)的合成过程中,N-亚硝基米拉贝琼(NNM)是在米拉贝琼的合成过程中获得的;水在酸性条件下用于反应。亚硝酸盐来源于水,仲胺来源于 MIR,因为 MIR 具有仲胺;NNM 是 MIR 合成过程中产生的杂质。MIR 中含有 NNM 可能会影响其功效。本研究的目的是建立一种超高效液相色谱-质谱/质谱(UPLC-MS/MS)方法,以鉴定 MIR 样品中的 NNM。NNM 分析方法采用 Acquity HSS T3 (100*2.1) mm 1.8 μm 色谱柱,以 0.1% 甲酸水溶液(流动相 A)和 0.1% 甲酸甲醇(流动相 B)为流动相进行梯度洗脱。采用电喷雾离子化质谱仪,以 MRM 模式分析 NNM(m/ z 426.20 → 170.00)。所提出的 UPLC-MS/MS 方法对 NNM 具有良好的线性(0.02 至 0.72 ppm)、良好的系统精密度(RSD = 0.57%)、良好的方法精密度(RSD = 0.87%)、可接受的准确度(94.5-116.5%)、较低的检测限(0.006 ppm)和较低的定量限(0.02 ppm)。所提出的 UPLC-MS/MS 方法可用于评估 MIR 样品中 NNM 杂质的质量。
Development of an UPLC-MS/MS approach to detect and quantify N-nitroso mirabegron in mirabegron
In the mirabegron (MIR) synthesis, the N-nitroso mirabegron (NNM) is obtained during synthetic process of MIR; water is being used in reaction under acidic condition. Nitrite source is from water, and secondary amine source is from MIR as it has secondary amine; NNM is generated as an impurity during the synthesis of MIR. The presence of NNM in MIR could potentially affect its effectiveness. The purpose of this study was to establish a Ultra-performance liquid chromatography-mass spectrometry/mass spectrometry (UPLC-MS/MS) methodology to identify NNM in MIR samples. The method for NNM analysis was developed on Acquity HSS T3 (100*2.1) mm 1.8 μm column with gradient elution using mobile phase consisted of 0.1% formic acid in water (mobile phase A) and 0.1% formic acid in methanol (mobile phase B). Mass spectrometer with electrospray ionization operated in the MRM mode was used in the analysis of NNM (m/ z 426.20 → 170.00). The UPLC-MS/MS methodology proposed showed a good linearity (0.02 to 0.72 ppm), good system precision (RSD = 0.57%), good method precision (RSD = 0.87%), acceptable accuracy (94.5–116.5%), low detection limit (0.006 ppm) and low quantification limit (0.02 ppm) for NNM. The UPLC-MS/MS methodology proposed can be utilized to assess the quality of MIR sample for the presence of NNM impurity.
期刊介绍:
Rapid Communications in Mass Spectrometry is a journal whose aim is the rapid publication of original research results and ideas on all aspects of the science of gas-phase ions; it covers all the associated scientific disciplines. There is no formal limit on paper length ("rapid" is not synonymous with "brief"), but papers should be of a length that is commensurate with the importance and complexity of the results being reported. Contributions may be theoretical or practical in nature; they may deal with methods, techniques and applications, or with the interpretation of results; they may cover any area in science that depends directly on measurements made upon gaseous ions or that is associated with such measurements.