激光诱导石墨烯与分层双氢氧化镍钴层状纳米片的结合用于食品和血清中葡萄糖的电化学测定

IF 5.7 2区 化学 Q1 CHEMISTRY, ANALYTICAL Analytica Chimica Acta Pub Date : 2024-09-03 DOI:10.1016/j.aca.2024.343194
{"title":"激光诱导石墨烯与分层双氢氧化镍钴层状纳米片的结合用于食品和血清中葡萄糖的电化学测定","authors":"","doi":"10.1016/j.aca.2024.343194","DOIUrl":null,"url":null,"abstract":"<div><p>Dependable and sensitive glucose (Glu) testing in foodstuff and blood serum is highly desirable to prevent and treat diabetes. Electrochemical quantification of Glu has attracted great interests due to the advantages, including simple operation, higher sensitivity, easy miniaturization, ease of on-site and wearable detection as well as fast response. High costs and environmental dependence of enzymes pose a challenge to the electrochemical enzymatic biosensors. Nonenzymatic electrochemical Glu sensors are urgently needed to aid the Glu detection in human serum and food samples. To fabricate flexible Glu electrochemical sensors, designing suitable electrode substrate and efficient electrocatalyst is of paramount significance. Herein, the porous patterned laser-induced graphene (LIG) was fabricated on polyimide substrates through an efficient laser-inducing technology, and then used directly as the electrode substrate. Electrochemical deposition of NiCo layered double hydroxide (LDH) nanoflakes on the LIG surface was then conducted to achieve NiCo-LDH/LIG electrode as a Glu sensor. Under optimal conditions, this sensor displays a low detection limit of 0.05 μM. Two sets of broad detection linear ranges were found to be from 0.5 to 270 μM and from 0.27 to 3.6 mM, with high sensitivities of 9.750 μA μM<sup>−1</sup> cm<sup>−2</sup> and 3.760 μA μM<sup>−1</sup> cm<sup>−2</sup>, respectively. The enhanced performance was ascribed to the cooperative action of NiCo-LDH and LIG, in which porous LIG provides extraordinary electroconductibility and a high surface area, while NiCo-LDH offers numerous exposed active sites and outstanding electrocatalytic performance. Practical application was further verified during the Glu detection in human serum and food samples. This research confirms that the NiCo-LDH/LIG composite is a prospective electrode for high-performance Glu sensor and provides a way of developing nonenzymatic electrochemical sensors to analyze the Glu in human serum and food samples, opening new avenues in electrochemical sensing.</p></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Incorporation of laser-induced graphene with hierarchical NiCo layered double hydroxide nanosheets for electrochemical determination of glucose in food and serum\",\"authors\":\"\",\"doi\":\"10.1016/j.aca.2024.343194\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Dependable and sensitive glucose (Glu) testing in foodstuff and blood serum is highly desirable to prevent and treat diabetes. Electrochemical quantification of Glu has attracted great interests due to the advantages, including simple operation, higher sensitivity, easy miniaturization, ease of on-site and wearable detection as well as fast response. High costs and environmental dependence of enzymes pose a challenge to the electrochemical enzymatic biosensors. Nonenzymatic electrochemical Glu sensors are urgently needed to aid the Glu detection in human serum and food samples. To fabricate flexible Glu electrochemical sensors, designing suitable electrode substrate and efficient electrocatalyst is of paramount significance. Herein, the porous patterned laser-induced graphene (LIG) was fabricated on polyimide substrates through an efficient laser-inducing technology, and then used directly as the electrode substrate. Electrochemical deposition of NiCo layered double hydroxide (LDH) nanoflakes on the LIG surface was then conducted to achieve NiCo-LDH/LIG electrode as a Glu sensor. Under optimal conditions, this sensor displays a low detection limit of 0.05 μM. Two sets of broad detection linear ranges were found to be from 0.5 to 270 μM and from 0.27 to 3.6 mM, with high sensitivities of 9.750 μA μM<sup>−1</sup> cm<sup>−2</sup> and 3.760 μA μM<sup>−1</sup> cm<sup>−2</sup>, respectively. The enhanced performance was ascribed to the cooperative action of NiCo-LDH and LIG, in which porous LIG provides extraordinary electroconductibility and a high surface area, while NiCo-LDH offers numerous exposed active sites and outstanding electrocatalytic performance. Practical application was further verified during the Glu detection in human serum and food samples. This research confirms that the NiCo-LDH/LIG composite is a prospective electrode for high-performance Glu sensor and provides a way of developing nonenzymatic electrochemical sensors to analyze the Glu in human serum and food samples, opening new avenues in electrochemical sensing.</p></div>\",\"PeriodicalId\":240,\"journal\":{\"name\":\"Analytica Chimica Acta\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytica Chimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0003267024009954\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267024009954","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

对食品和血清中的葡萄糖(Glu)进行可靠而灵敏的检测,是预防和治疗糖尿病的理想方法。电化学定量葡萄糖具有操作简单、灵敏度高、易于微型化、便于现场和可穿戴式检测以及响应速度快等优点,因此引起了人们的极大兴趣。酶的高成本和对环境的依赖性给电化学酶生物传感器带来了挑战。因此,迫切需要非酶电化学 Glu 传感器来帮助检测人体血清和食品样品中的 Glu。要制造灵活的 Glu 电化学传感器,设计合适的电极基底和高效的电催化剂至关重要。本文通过高效的激光诱导技术,在聚酰亚胺基底上制备了多孔图案化的激光诱导石墨烯(LIG),并将其直接用作电极基底。然后在石墨烯表面电化学沉积镍钴层状双氢氧化物(LDH)纳米片,实现了镍钴层状双氢氧化物/石墨烯电极作为 Glu 传感器。在最佳条件下,该传感器的检测限低至 0.05 μM。两组宽检测线性范围分别为 0.5 至 270 μM 和 0.27 至 3.6 mM,灵敏度分别为 9.750 μA μM cm 和 3.760 μA μM cm。性能的提高归功于镍钴-LDH 和 LIG 的协同作用,其中多孔 LIG 提供了非凡的电导性和高表面积,而镍钴-LDH 则提供了大量暴露的活性位点和出色的电催化性能。在人体血清和食品样品中的 Glu 检测中,进一步验证了其实际应用。这项研究证实,NiCo-LDH/LIG 复合材料是高性能 Glu 传感器的理想电极,并为开发分析人体血清和食品样品中 Glu 的非酶电化学传感器提供了一种方法,为电化学传感开辟了新途径。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Incorporation of laser-induced graphene with hierarchical NiCo layered double hydroxide nanosheets for electrochemical determination of glucose in food and serum

Dependable and sensitive glucose (Glu) testing in foodstuff and blood serum is highly desirable to prevent and treat diabetes. Electrochemical quantification of Glu has attracted great interests due to the advantages, including simple operation, higher sensitivity, easy miniaturization, ease of on-site and wearable detection as well as fast response. High costs and environmental dependence of enzymes pose a challenge to the electrochemical enzymatic biosensors. Nonenzymatic electrochemical Glu sensors are urgently needed to aid the Glu detection in human serum and food samples. To fabricate flexible Glu electrochemical sensors, designing suitable electrode substrate and efficient electrocatalyst is of paramount significance. Herein, the porous patterned laser-induced graphene (LIG) was fabricated on polyimide substrates through an efficient laser-inducing technology, and then used directly as the electrode substrate. Electrochemical deposition of NiCo layered double hydroxide (LDH) nanoflakes on the LIG surface was then conducted to achieve NiCo-LDH/LIG electrode as a Glu sensor. Under optimal conditions, this sensor displays a low detection limit of 0.05 μM. Two sets of broad detection linear ranges were found to be from 0.5 to 270 μM and from 0.27 to 3.6 mM, with high sensitivities of 9.750 μA μM−1 cm−2 and 3.760 μA μM−1 cm−2, respectively. The enhanced performance was ascribed to the cooperative action of NiCo-LDH and LIG, in which porous LIG provides extraordinary electroconductibility and a high surface area, while NiCo-LDH offers numerous exposed active sites and outstanding electrocatalytic performance. Practical application was further verified during the Glu detection in human serum and food samples. This research confirms that the NiCo-LDH/LIG composite is a prospective electrode for high-performance Glu sensor and provides a way of developing nonenzymatic electrochemical sensors to analyze the Glu in human serum and food samples, opening new avenues in electrochemical sensing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
期刊最新文献
An electrochemiluminescence sensor for ultrasensitive determination tyrosine based on ceria nanomaterial as a novel luminophor Microfluidic-based fluorescence enhancement of silica-embedded carbon dots for direct detection and quantification of unamplified HCV RNA in clinical samples Hydrogel loop-mediated isothermal amplification for ultra-fast diagnosis of Helicobacter pylori in stool samples without nucleic acid extraction Amino-enriched Zn-MOFs with self-reduction for energy-free simultaneous removal and electrochemical detection of heavy metal ions in the aquatic environment Effervescence-assisted dispersive liquid-liquid microextraction for the extraction and preconcentration of pesticide residues in fruit juice samples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1