Armin Zarrintan, Sherief Ghozy, Seyed Farzad Maroufi, Abdullah Reda, Waleed Brinjikji, Ramanathan Kadirvel, David F Kallmes
{"title":"血流分流术在复发性颅内动脉瘤再治疗中的疗效和安全性--系统回顾和荟萃分析","authors":"Armin Zarrintan, Sherief Ghozy, Seyed Farzad Maroufi, Abdullah Reda, Waleed Brinjikji, Ramanathan Kadirvel, David F Kallmes","doi":"10.1177/15910199241282713","DOIUrl":null,"url":null,"abstract":"Background and purposeTreatment of recurrent intracranial aneurysms after their initial therapy has been a significant challenge in the field of neurointervention. Recently flow diverters stents are widely used for treating intracranial aneurysms. In this systematic review and meta-analysis, we assessed the safety and efficacy of flow diverter in treating recurrent or recanalized intracranial aneurysms.MethodsThis meta-analysis is reported following the PRISMA 2020 guidelines. We conducted a systematic review of literature in the PubMed, Embase, Web of Sciences, and Scopus databases. Pooled prevalence and the corresponding 95% are calculated from extracted data using a random-effect model.ResultsThe systematic literature search included 21 studies involving 411 patients, with 135 (32.8%) being male and 276 (67.2%) being females with a total number of 447 aneurysms. The overall rate of adequate occlusion was 90.67% (95% CI: 84.23%–94.65%), and the rates were comparable between the surgery (93.48%), coiling (91.78%), and stenting (85.77%) groups. The overall pooled rate of complete occlusion was 81.80 (95% CI: 71.14%–89.13%). On doing a subgroup analysis, the complete occlusion rates were 89.68%, 84.39%, and 73.47% for the surgery, coiling, and stenting groups, respectively. The overall mortality rate and achieving modified Rankin scale score of 0-2 was 1.28% (95% CI: 0.45%–3.64%) and (95% CI: 89.92%–97.84%), respectively. No significant heterogeneity is noted in the included studies.ConclusionFlow diverter stents are an effective and safe method for retreating recurrent or residual intracranial aneurysms with a high rate of complete and adequate occlusion. The rate of mortality, intracerebral hemorrhage, and overall and procedural complications following using flow diverters for intracranial aneurysms is low.","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":"97 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Efficacy and safety of flow diverters in retreatment of recurrent intracranial aneurysms—A systematic review and meta-analysis\",\"authors\":\"Armin Zarrintan, Sherief Ghozy, Seyed Farzad Maroufi, Abdullah Reda, Waleed Brinjikji, Ramanathan Kadirvel, David F Kallmes\",\"doi\":\"10.1177/15910199241282713\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and purposeTreatment of recurrent intracranial aneurysms after their initial therapy has been a significant challenge in the field of neurointervention. Recently flow diverters stents are widely used for treating intracranial aneurysms. In this systematic review and meta-analysis, we assessed the safety and efficacy of flow diverter in treating recurrent or recanalized intracranial aneurysms.MethodsThis meta-analysis is reported following the PRISMA 2020 guidelines. We conducted a systematic review of literature in the PubMed, Embase, Web of Sciences, and Scopus databases. Pooled prevalence and the corresponding 95% are calculated from extracted data using a random-effect model.ResultsThe systematic literature search included 21 studies involving 411 patients, with 135 (32.8%) being male and 276 (67.2%) being females with a total number of 447 aneurysms. The overall rate of adequate occlusion was 90.67% (95% CI: 84.23%–94.65%), and the rates were comparable between the surgery (93.48%), coiling (91.78%), and stenting (85.77%) groups. The overall pooled rate of complete occlusion was 81.80 (95% CI: 71.14%–89.13%). On doing a subgroup analysis, the complete occlusion rates were 89.68%, 84.39%, and 73.47% for the surgery, coiling, and stenting groups, respectively. The overall mortality rate and achieving modified Rankin scale score of 0-2 was 1.28% (95% CI: 0.45%–3.64%) and (95% CI: 89.92%–97.84%), respectively. No significant heterogeneity is noted in the included studies.ConclusionFlow diverter stents are an effective and safe method for retreating recurrent or residual intracranial aneurysms with a high rate of complete and adequate occlusion. The rate of mortality, intracerebral hemorrhage, and overall and procedural complications following using flow diverters for intracranial aneurysms is low.\",\"PeriodicalId\":14380,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":\"97 1\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199241282713\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241282713","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Efficacy and safety of flow diverters in retreatment of recurrent intracranial aneurysms—A systematic review and meta-analysis
Background and purposeTreatment of recurrent intracranial aneurysms after their initial therapy has been a significant challenge in the field of neurointervention. Recently flow diverters stents are widely used for treating intracranial aneurysms. In this systematic review and meta-analysis, we assessed the safety and efficacy of flow diverter in treating recurrent or recanalized intracranial aneurysms.MethodsThis meta-analysis is reported following the PRISMA 2020 guidelines. We conducted a systematic review of literature in the PubMed, Embase, Web of Sciences, and Scopus databases. Pooled prevalence and the corresponding 95% are calculated from extracted data using a random-effect model.ResultsThe systematic literature search included 21 studies involving 411 patients, with 135 (32.8%) being male and 276 (67.2%) being females with a total number of 447 aneurysms. The overall rate of adequate occlusion was 90.67% (95% CI: 84.23%–94.65%), and the rates were comparable between the surgery (93.48%), coiling (91.78%), and stenting (85.77%) groups. The overall pooled rate of complete occlusion was 81.80 (95% CI: 71.14%–89.13%). On doing a subgroup analysis, the complete occlusion rates were 89.68%, 84.39%, and 73.47% for the surgery, coiling, and stenting groups, respectively. The overall mortality rate and achieving modified Rankin scale score of 0-2 was 1.28% (95% CI: 0.45%–3.64%) and (95% CI: 89.92%–97.84%), respectively. No significant heterogeneity is noted in the included studies.ConclusionFlow diverter stents are an effective and safe method for retreating recurrent or residual intracranial aneurysms with a high rate of complete and adequate occlusion. The rate of mortality, intracerebral hemorrhage, and overall and procedural complications following using flow diverters for intracranial aneurysms is low.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...