{"title":"在 1Hz 和 1MHz 之间测量和比较人体胰腺肿瘤、健康组织和猪组织的活体介电特性","authors":"Théo Le Berre ,&nbsp;Julien Marchalot ,&nbsp;Marie Frénéa-Robin ,&nbsp;Jérôme Cros ,&nbsp;Frédéric Prat ,&nbsp;Guilhem Rival","doi":"10.1016/j.bioelechem.2024.108821","DOIUrl":null,"url":null,"abstract":"<div><p>The dielectric properties of pancreatic tissues from human healthy and tumour-bearing tissues have been extracted from impedance measurement on <em>ex vivo</em>, freshly excised samples. They are compared to pig pancreas samples, measured following the same protocol. The purpose is to add data to the scarce literature on the properties of the human pancreas and pancreatic tumours, for treatment planning, tissue identification and numerical simulations. The conductivity measured at 500 kHz for human healthy pancreas is 0.26 S/m, while the conductivity of tumour-bearing tissues is 0.44 S/m. Those values differ significantly from that listed in the IT IS database at 0.57 S/m, suggesting an update might be to consider. However, measures of relative permittivity are in accordance with the database with a value of approximately 2.3x10<sup>3</sup>. <em>Ex vivo</em> porcine model, while being less conductive than human pancreas with 0.16 S/m at the same frequency, is deemed a relevant model when studying pancreatic applications of electromagnetic fields-based treatments, such as radiofrequency ablation.</p></div>","PeriodicalId":252,"journal":{"name":"Bioelectrochemistry","volume":"161 ","pages":"Article 108821"},"PeriodicalIF":4.8000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S156753942400183X/pdfft?md5=923a6632fbe84dbd4e3e70d111d5b20d&pid=1-s2.0-S156753942400183X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Measurement and comparison of dielectric properties of human pancreatic tumours, healthy tissues and porcine tissues ex vivo between 1Hz and 1MHz\",\"authors\":\"Théo Le Berre ,&nbsp;Julien Marchalot ,&nbsp;Marie Frénéa-Robin ,&nbsp;Jérôme Cros ,&nbsp;Frédéric Prat ,&nbsp;Guilhem Rival\",\"doi\":\"10.1016/j.bioelechem.2024.108821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The dielectric properties of pancreatic tissues from human healthy and tumour-bearing tissues have been extracted from impedance measurement on <em>ex vivo</em>, freshly excised samples. They are compared to pig pancreas samples, measured following the same protocol. The purpose is to add data to the scarce literature on the properties of the human pancreas and pancreatic tumours, for treatment planning, tissue identification and numerical simulations. The conductivity measured at 500 kHz for human healthy pancreas is 0.26 S/m, while the conductivity of tumour-bearing tissues is 0.44 S/m. Those values differ significantly from that listed in the IT IS database at 0.57 S/m, suggesting an update might be to consider. However, measures of relative permittivity are in accordance with the database with a value of approximately 2.3x10<sup>3</sup>. <em>Ex vivo</em> porcine model, while being less conductive than human pancreas with 0.16 S/m at the same frequency, is deemed a relevant model when studying pancreatic applications of electromagnetic fields-based treatments, such as radiofrequency ablation.</p></div>\",\"PeriodicalId\":252,\"journal\":{\"name\":\"Bioelectrochemistry\",\"volume\":\"161 \",\"pages\":\"Article 108821\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S156753942400183X/pdfft?md5=923a6632fbe84dbd4e3e70d111d5b20d&pid=1-s2.0-S156753942400183X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioelectrochemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S156753942400183X\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioelectrochemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S156753942400183X","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

通过对新鲜切除的体外样本进行阻抗测量,提取了人体健康胰腺组织和肿瘤胰腺组织的介电特性。它们与按照相同方案测量的猪胰腺样本进行了比较。目的是为有关人体胰腺和胰腺肿瘤特性的稀缺文献增添数据,以用于治疗规划、组织识别和数值模拟。人体健康胰腺在 500 kHz 频率下测得的电导率为 0.26 S/m,而肿瘤组织的电导率为 0.44 S/m。这些数值与 IT IS 数据库中列出的 0.57 S/m 有很大差异,表明可能需要考虑更新。不过,相对介电常数的测量值与数据库一致,约为 2.3x103。猪体内外模型在相同频率下的导电性低于 0.16 S/m 的人体胰腺,但在研究基于电磁场的胰腺应用治疗(如射频消融)时,猪体内外模型被认为是一个相关模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement and comparison of dielectric properties of human pancreatic tumours, healthy tissues and porcine tissues ex vivo between 1Hz and 1MHz

The dielectric properties of pancreatic tissues from human healthy and tumour-bearing tissues have been extracted from impedance measurement on ex vivo, freshly excised samples. They are compared to pig pancreas samples, measured following the same protocol. The purpose is to add data to the scarce literature on the properties of the human pancreas and pancreatic tumours, for treatment planning, tissue identification and numerical simulations. The conductivity measured at 500 kHz for human healthy pancreas is 0.26 S/m, while the conductivity of tumour-bearing tissues is 0.44 S/m. Those values differ significantly from that listed in the IT IS database at 0.57 S/m, suggesting an update might be to consider. However, measures of relative permittivity are in accordance with the database with a value of approximately 2.3x103. Ex vivo porcine model, while being less conductive than human pancreas with 0.16 S/m at the same frequency, is deemed a relevant model when studying pancreatic applications of electromagnetic fields-based treatments, such as radiofrequency ablation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bioelectrochemistry
Bioelectrochemistry 生物-电化学
CiteScore
9.10
自引率
6.00%
发文量
238
审稿时长
38 days
期刊介绍: An International Journal Devoted to Electrochemical Aspects of Biology and Biological Aspects of Electrochemistry Bioelectrochemistry is an international journal devoted to electrochemical principles in biology and biological aspects of electrochemistry. It publishes experimental and theoretical papers dealing with the electrochemical aspects of: • Electrified interfaces (electric double layers, adsorption, electron transfer, protein electrochemistry, basic principles of biosensors, biosensor interfaces and bio-nanosensor design and construction. • Electric and magnetic field effects (field-dependent processes, field interactions with molecules, intramolecular field effects, sensory systems for electric and magnetic fields, molecular and cellular mechanisms) • Bioenergetics and signal transduction (energy conversion, photosynthetic and visual membranes) • Biomembranes and model membranes (thermodynamics and mechanics, membrane transport, electroporation, fusion and insertion) • Electrochemical applications in medicine and biotechnology (drug delivery and gene transfer to cells and tissues, iontophoresis, skin electroporation, injury and repair). • Organization and use of arrays in-vitro and in-vivo, including as part of feedback control. • Electrochemical interrogation of biofilms as generated by microorganisms and tissue reaction associated with medical implants.
期刊最新文献
Enhanced corrosion resistance and biofilm inhibition of TC4 with slight Cu addition against marine Pseudomonas aeruginosa. Corrigendum to "Molecular monolayers on silicon as substrates for biosensors" [Bioelectrochem. 80(1) (2010) 17-25]. Label-free electrochemical biosensor with magnetic self-assembly constructed via PNA-DNA hybridization process on α-Fe2O3/Fe3O4 nanosheets for APOE ε4 genes ultrasensitive detection Time-resolved electromechanical and conductive behavior of nanostructured bilayers tethered to the surface of the electrode with incorporated channel proteins and peptides. Sensitive detection of K-ras gene by a dual-mode “on-off-on” sensor based on bipyridine ruthenium-MOF and bis-enzymatic cleavage technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1