{"title":"自制气管插管输氧装置在术后麻醉恢复期间进行氧疗的功效。","authors":"Yi-Ying Xiong, Chao-Yang Chen, Xiang Li, Xin-Xin Yue, Ze-Yu Zhao","doi":"10.3233/THC-241184","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients with tracheotomy are often monitored in the anesthesia recovery room after reoperation. During this period, oxygen therapy is necessary, and the existing tracheostomy oxygen supply device has many defects.</p><p><strong>Objective: </strong>To evaluate the efficacy of a self-made tracheostomy oxygen delivery device on oxygen therapy during postoperative anesthesia recovery.</p><p><strong>Methods: </strong>Patients were randomly divided into two groups, E and C, with 30 patients in each group, and admitted to the post-anesthesia care unit (PACU). Patients in group E received oxygen through a self-made tracheostomy oxygen delivery device, while patients in group C were supplied oxygen through a unilateral nasal cannula. Respiration (R), pulse oximetry (SpO2), and the number of patients on ventilators were recorded at the time of admission (T0) and one hour after admission (T1). Rapid dry blood gas analyses were performed on 0.6 ml samples of arterial blood collected at T0 and T1.</p><p><strong>Results: </strong>Compared to group C, patients in group E had significantly higher arterial partial pressure of oxygen (PaO2), arterial oxygen saturation (SaO2), total carbon dioxide (T-CO2), and actual bicarbonate (AB), while arterial partial pressure of carbon dioxide (PaCO2) was significantly reduced (P< 0.01 or < 0.05). Compared to T0, PaO2 decreased in both groups at T1, PaCO2 decreased in group E, while SaO2, T-CO2, and AB decreased in group C (P< 0.01 or < 0.05).</p><p><strong>Conclusion: </strong>We found that using the self-made tracheostomy oxygen delivery device in postoperative anesthesia recovery had advantages such as a secure connection to the tracheostoma, adjustable oxygen concentration, air filtration, and the ability to switch oxygen supply between the ventilator and humidifier.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Efficacy of a self-made tracheostomy oxygen delivery device for oxygen therapy during postoperative anesthesia recovery.\",\"authors\":\"Yi-Ying Xiong, Chao-Yang Chen, Xiang Li, Xin-Xin Yue, Ze-Yu Zhao\",\"doi\":\"10.3233/THC-241184\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Patients with tracheotomy are often monitored in the anesthesia recovery room after reoperation. During this period, oxygen therapy is necessary, and the existing tracheostomy oxygen supply device has many defects.</p><p><strong>Objective: </strong>To evaluate the efficacy of a self-made tracheostomy oxygen delivery device on oxygen therapy during postoperative anesthesia recovery.</p><p><strong>Methods: </strong>Patients were randomly divided into two groups, E and C, with 30 patients in each group, and admitted to the post-anesthesia care unit (PACU). Patients in group E received oxygen through a self-made tracheostomy oxygen delivery device, while patients in group C were supplied oxygen through a unilateral nasal cannula. Respiration (R), pulse oximetry (SpO2), and the number of patients on ventilators were recorded at the time of admission (T0) and one hour after admission (T1). Rapid dry blood gas analyses were performed on 0.6 ml samples of arterial blood collected at T0 and T1.</p><p><strong>Results: </strong>Compared to group C, patients in group E had significantly higher arterial partial pressure of oxygen (PaO2), arterial oxygen saturation (SaO2), total carbon dioxide (T-CO2), and actual bicarbonate (AB), while arterial partial pressure of carbon dioxide (PaCO2) was significantly reduced (P< 0.01 or < 0.05). Compared to T0, PaO2 decreased in both groups at T1, PaCO2 decreased in group E, while SaO2, T-CO2, and AB decreased in group C (P< 0.01 or < 0.05).</p><p><strong>Conclusion: </strong>We found that using the self-made tracheostomy oxygen delivery device in postoperative anesthesia recovery had advantages such as a secure connection to the tracheostoma, adjustable oxygen concentration, air filtration, and the ability to switch oxygen supply between the ventilator and humidifier.</p>\",\"PeriodicalId\":48978,\"journal\":{\"name\":\"Technology and Health Care\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technology and Health Care\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/THC-241184\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/THC-241184","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
摘要
背景:气管切开术患者在再次手术后通常需要在麻醉恢复室接受监测。在此期间,必须进行氧疗,而现有的气管切开供氧装置存在许多缺陷:评估自制气管切开供氧装置对术后麻醉恢复期氧疗的效果:将患者随机分为 E 和 C 两组,每组 30 人,入住麻醉后护理病房(PACU)。E 组患者通过自制的气管插管输氧装置吸氧,C 组患者通过单侧鼻插管供氧。入院时(T0)和入院后一小时(T1)记录患者的呼吸(R)、脉搏血氧饱和度(SpO2)和使用呼吸机的人数。对在 T0 和 T1 采集的 0.6 毫升动脉血样本进行快速干血气分析:与 C 组相比,E 组患者的动脉血氧分压(PaO2)、动脉血氧饱和度(SaO2)、总二氧化碳(T-CO2)和实际碳酸氢盐(AB)明显升高,而动脉血二氧化碳分压(PaCO2)明显降低(P< 0.01 或 < 0.05)。与 T0 相比,两组在 T1 时的 PaO2 均下降,E 组的 PaCO2 下降,而 C 组的 SaO2、T-CO2 和 AB 均下降(P< 0.01 或 < 0.05):我们发现,在术后麻醉恢复中使用自制气管造口给氧装置具有安全连接气管造口、氧气浓度可调、空气过滤、可在呼吸机和加湿器之间切换供氧等优点。
Efficacy of a self-made tracheostomy oxygen delivery device for oxygen therapy during postoperative anesthesia recovery.
Background: Patients with tracheotomy are often monitored in the anesthesia recovery room after reoperation. During this period, oxygen therapy is necessary, and the existing tracheostomy oxygen supply device has many defects.
Objective: To evaluate the efficacy of a self-made tracheostomy oxygen delivery device on oxygen therapy during postoperative anesthesia recovery.
Methods: Patients were randomly divided into two groups, E and C, with 30 patients in each group, and admitted to the post-anesthesia care unit (PACU). Patients in group E received oxygen through a self-made tracheostomy oxygen delivery device, while patients in group C were supplied oxygen through a unilateral nasal cannula. Respiration (R), pulse oximetry (SpO2), and the number of patients on ventilators were recorded at the time of admission (T0) and one hour after admission (T1). Rapid dry blood gas analyses were performed on 0.6 ml samples of arterial blood collected at T0 and T1.
Results: Compared to group C, patients in group E had significantly higher arterial partial pressure of oxygen (PaO2), arterial oxygen saturation (SaO2), total carbon dioxide (T-CO2), and actual bicarbonate (AB), while arterial partial pressure of carbon dioxide (PaCO2) was significantly reduced (P< 0.01 or < 0.05). Compared to T0, PaO2 decreased in both groups at T1, PaCO2 decreased in group E, while SaO2, T-CO2, and AB decreased in group C (P< 0.01 or < 0.05).
Conclusion: We found that using the self-made tracheostomy oxygen delivery device in postoperative anesthesia recovery had advantages such as a secure connection to the tracheostoma, adjustable oxygen concentration, air filtration, and the ability to switch oxygen supply between the ventilator and humidifier.
期刊介绍:
Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered:
1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables.
2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words.
Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics.
4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors.
5.Letters to the Editors: Discussions or short statements (not indexed).