{"title":"将液相色谱分离储存在表面能阱中:解耦液相色谱和质谱仪†","authors":"Timothy T. Salomons, David Simon and Richard Oleschuk","doi":"10.1039/D4AN00828F","DOIUrl":null,"url":null,"abstract":"<p >We report a micro-fractionation device for high performance liquid chromatography-mass spectrometry to archive chromatographic separations on an array of optimized surface energy traps (SETs). The method has the potential to significantly alter nanoflow LC-MS workflow, decoupling separation and analysis. The wetting characteristics of the SETs cause the HPLC eluent stream to spontaneously split into droplet microfractions. The droplet mirofractions are then dried down to enable facile storage and transport of the archived separation. Discontinuously dewetting array parameters were explored to maximize array volume and resolution using a combination of SET design, shape, size, and spacing. Mass spectrometry analysis is performed utilizing a liquid micro-junction surface sampling probe to extract dried analytes from the surface of the SETs followed by electrospray ionisation. A reverse phase separation of pharmaceutical compounds is “recorded” using the micro-fractionation device followed by “reading” the chromatographic trace with a mass spectrometer 24 hours after the separation was performed/archived, demonstrating a true decoupling of LC, and MS. Additionally, we demonstrate the ability to collect microfractions with sub-one-second integration time, approaching the scan time of a mass spectrometer or UV-Vis detector. With further improvements to the device, sub-1-second micro-fractionation may enable seamless reconstruction of archived chromatograms indistinguishable from online LC-MS data, while also providing the benefits of easy storage and transport of archived separations.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 21","pages":" 5336-5343"},"PeriodicalIF":3.6000,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Storing liquid chromatographic separations on surface energy traps: decoupling the LC and the mass spectrometer†\",\"authors\":\"Timothy T. Salomons, David Simon and Richard Oleschuk\",\"doi\":\"10.1039/D4AN00828F\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >We report a micro-fractionation device for high performance liquid chromatography-mass spectrometry to archive chromatographic separations on an array of optimized surface energy traps (SETs). The method has the potential to significantly alter nanoflow LC-MS workflow, decoupling separation and analysis. The wetting characteristics of the SETs cause the HPLC eluent stream to spontaneously split into droplet microfractions. The droplet mirofractions are then dried down to enable facile storage and transport of the archived separation. Discontinuously dewetting array parameters were explored to maximize array volume and resolution using a combination of SET design, shape, size, and spacing. Mass spectrometry analysis is performed utilizing a liquid micro-junction surface sampling probe to extract dried analytes from the surface of the SETs followed by electrospray ionisation. A reverse phase separation of pharmaceutical compounds is “recorded” using the micro-fractionation device followed by “reading” the chromatographic trace with a mass spectrometer 24 hours after the separation was performed/archived, demonstrating a true decoupling of LC, and MS. Additionally, we demonstrate the ability to collect microfractions with sub-one-second integration time, approaching the scan time of a mass spectrometer or UV-Vis detector. With further improvements to the device, sub-1-second micro-fractionation may enable seamless reconstruction of archived chromatograms indistinguishable from online LC-MS data, while also providing the benefits of easy storage and transport of archived separations.</p>\",\"PeriodicalId\":63,\"journal\":{\"name\":\"Analyst\",\"volume\":\" 21\",\"pages\":\" 5336-5343\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analyst\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00828f\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/an/d4an00828f","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们报告了一种用于高效液相色谱-质谱联用技术的微型分馏装置,可将色谱分离过程归档到优化的表面能阱(SET)阵列上。该方法有望显著改变纳升液相色谱-质谱工作流程,实现分离与分析的解耦。SET 的润湿特性可使 HPLC 洗脱液流自发分裂成液滴微馏分。然后对液滴微馏分进行干燥,以便于存档分离的储存和运输。通过结合 SET 的设计、形状、大小和间距,探索了间断脱水阵列参数,以最大限度地提高阵列体积和分辨率。利用液态微结表面取样探针从 SET 表面提取干燥的分析物,然后进行电喷雾离子化,从而进行质谱分析。使用微分馏装置 "记录 "药物化合物的反相分离,然后在分离/存档 24 小时后使用质谱仪 "读取 "色谱跟踪,从而展示了液相色谱和质谱的真正解耦。此外,我们还展示了以亚一秒积分时间收集微馏分的能力,接近质谱仪或紫外可见检测器的扫描时间。随着设备的进一步改进,1 秒以下的微馏分可实现与在线 LC-MS 数据无异的存档色谱图的无缝重建,同时还具有便于存储和运输存档分离物的优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Storing liquid chromatographic separations on surface energy traps: decoupling the LC and the mass spectrometer†

We report a micro-fractionation device for high performance liquid chromatography-mass spectrometry to archive chromatographic separations on an array of optimized surface energy traps (SETs). The method has the potential to significantly alter nanoflow LC-MS workflow, decoupling separation and analysis. The wetting characteristics of the SETs cause the HPLC eluent stream to spontaneously split into droplet microfractions. The droplet mirofractions are then dried down to enable facile storage and transport of the archived separation. Discontinuously dewetting array parameters were explored to maximize array volume and resolution using a combination of SET design, shape, size, and spacing. Mass spectrometry analysis is performed utilizing a liquid micro-junction surface sampling probe to extract dried analytes from the surface of the SETs followed by electrospray ionisation. A reverse phase separation of pharmaceutical compounds is “recorded” using the micro-fractionation device followed by “reading” the chromatographic trace with a mass spectrometer 24 hours after the separation was performed/archived, demonstrating a true decoupling of LC, and MS. Additionally, we demonstrate the ability to collect microfractions with sub-one-second integration time, approaching the scan time of a mass spectrometer or UV-Vis detector. With further improvements to the device, sub-1-second micro-fractionation may enable seamless reconstruction of archived chromatograms indistinguishable from online LC-MS data, while also providing the benefits of easy storage and transport of archived separations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: The home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences
期刊最新文献
In-situ monitoring of Quorum Sensing signalling molecules by a SERS chip with array micro-chambers Novel Ratiometric Fluorescent Probe based on Internal Reference of Lanthanide/nucleotide for Alkaline Phosphatase Detection Reliable and Precise Lipoprotein Detection based on the Self-Priming Hairpin-Triggered Cas12a/crRNA based Signaling Strategy Nanofibers Decorated with High-Entropy Alloy Particles for the Detection of Nitrites Mechanically Stabilized UiO-66-NH2-MB Screen Printed Carbon Electrode for High Performance Electrochemical Ratiometric Quantification of miR-21-5p†
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1