Taís Tavares de Oliveira, Math H.J. Bollen, Nicholas Etherden
{"title":"基于托管容量的配电系统规划方法,适用于光伏发电的高渗透率","authors":"Taís Tavares de Oliveira, Math H.J. Bollen, Nicholas Etherden","doi":"10.1016/j.epsr.2024.111138","DOIUrl":null,"url":null,"abstract":"<div><div>This paper presents an approach to estimate the hosting capacity for distribution networks considering the impact of PV penetration at different voltage levels. The estimation and the method were selected such that the results were most suitable for distribution system planning. A time-series based method was used as it covers significant aspects needed for prioritising network reinforcement. The MV background voltage was modelled varying in time, assuming the same penetration level in the other LV networks supplied by the same MV system. The hosting capacity is defined as the maximum acceptable PV size per customer for a given PV penetration. Based on the different possible combinations of PV location, the probability of overvoltage and overloading is used as a performance index. The planning risk is used as a limit for the performance criterion. The method can be automated for a large number of networks due to using an IEC 61970-based input format. It also enables linking DSO network models to customer smart metre databases. The severity and risks of limit violations are analysed with different metrics from the time-series simulations. The change in background voltage with increasing penetration is shown to impact the results significantly. When considering it, the estimated hosting capacity was reduced by 32 %, on average.</div></div>","PeriodicalId":50547,"journal":{"name":"Electric Power Systems Research","volume":"238 ","pages":"Article 111138"},"PeriodicalIF":3.3000,"publicationDate":"2024-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A hosting capacity based approach toward distribution system planning for high PV penetration\",\"authors\":\"Taís Tavares de Oliveira, Math H.J. Bollen, Nicholas Etherden\",\"doi\":\"10.1016/j.epsr.2024.111138\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>This paper presents an approach to estimate the hosting capacity for distribution networks considering the impact of PV penetration at different voltage levels. The estimation and the method were selected such that the results were most suitable for distribution system planning. A time-series based method was used as it covers significant aspects needed for prioritising network reinforcement. The MV background voltage was modelled varying in time, assuming the same penetration level in the other LV networks supplied by the same MV system. The hosting capacity is defined as the maximum acceptable PV size per customer for a given PV penetration. Based on the different possible combinations of PV location, the probability of overvoltage and overloading is used as a performance index. The planning risk is used as a limit for the performance criterion. The method can be automated for a large number of networks due to using an IEC 61970-based input format. It also enables linking DSO network models to customer smart metre databases. The severity and risks of limit violations are analysed with different metrics from the time-series simulations. The change in background voltage with increasing penetration is shown to impact the results significantly. When considering it, the estimated hosting capacity was reduced by 32 %, on average.</div></div>\",\"PeriodicalId\":50547,\"journal\":{\"name\":\"Electric Power Systems Research\",\"volume\":\"238 \",\"pages\":\"Article 111138\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electric Power Systems Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0378779624010241\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electric Power Systems Research","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378779624010241","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
A hosting capacity based approach toward distribution system planning for high PV penetration
This paper presents an approach to estimate the hosting capacity for distribution networks considering the impact of PV penetration at different voltage levels. The estimation and the method were selected such that the results were most suitable for distribution system planning. A time-series based method was used as it covers significant aspects needed for prioritising network reinforcement. The MV background voltage was modelled varying in time, assuming the same penetration level in the other LV networks supplied by the same MV system. The hosting capacity is defined as the maximum acceptable PV size per customer for a given PV penetration. Based on the different possible combinations of PV location, the probability of overvoltage and overloading is used as a performance index. The planning risk is used as a limit for the performance criterion. The method can be automated for a large number of networks due to using an IEC 61970-based input format. It also enables linking DSO network models to customer smart metre databases. The severity and risks of limit violations are analysed with different metrics from the time-series simulations. The change in background voltage with increasing penetration is shown to impact the results significantly. When considering it, the estimated hosting capacity was reduced by 32 %, on average.
期刊介绍:
Electric Power Systems Research is an international medium for the publication of original papers concerned with the generation, transmission, distribution and utilization of electrical energy. The journal aims at presenting important results of work in this field, whether in the form of applied research, development of new procedures or components, orginal application of existing knowledge or new designapproaches. The scope of Electric Power Systems Research is broad, encompassing all aspects of electric power systems. The following list of topics is not intended to be exhaustive, but rather to indicate topics that fall within the journal purview.
• Generation techniques ranging from advances in conventional electromechanical methods, through nuclear power generation, to renewable energy generation.
• Transmission, spanning the broad area from UHV (ac and dc) to network operation and protection, line routing and design.
• Substation work: equipment design, protection and control systems.
• Distribution techniques, equipment development, and smart grids.
• The utilization area from energy efficiency to distributed load levelling techniques.
• Systems studies including control techniques, planning, optimization methods, stability, security assessment and insulation coordination.