通过连续血糖和体力活动监测以及深度学习,实现精确、个性化血糖预测的平台

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL Medical Engineering & Physics Pub Date : 2024-10-01 DOI:10.1016/j.medengphy.2024.104241
Deepjyoti Kalita , Hrishita Sharma , Jayanta Kumar Panda , Khalid B. Mirza
{"title":"通过连续血糖和体力活动监测以及深度学习,实现精确、个性化血糖预测的平台","authors":"Deepjyoti Kalita ,&nbsp;Hrishita Sharma ,&nbsp;Jayanta Kumar Panda ,&nbsp;Khalid B. Mirza","doi":"10.1016/j.medengphy.2024.104241","DOIUrl":null,"url":null,"abstract":"<div><div>Emerging research has demonstrated the advantage of continuous glucose monitoring for use in artificial pancreas and diabetes management in general. Recent studies demonstrate that glucose level forecasting using deep learning can help avoid postprandial hyperglycemia (≥ 180 mg/dL) or hypoglycemia (≤70 mg/dL) from delayed or increased insulin dosing in artificial pancreas. In this paper, a novel hybrid deep learning framework with integration of content-based attention learning is presented, to effectively predict the glucose measurements with prediction horizons (PH) = 15, 30 and, 60 minutes for T1D and T2D patients based on past data. We also present a complete cloud-based system and mobile app used for collecting CGM sensor, physical activity data, CHO values and insulin measurements to perform glucose forecasts using the proposed model running on Cloud. This model was validated using clinical data of individual with Type 1 diabetes (OhioT1DM) and individual with Type 2 diabetes. The mean absolute relative difference (MARD) was 12.33±3.15, 7.14±1.76% for PH=60 and, 30 min respectively on OhioT1DM clinical Dataset. The root mean squared error (RMSE) was 29.41±5.92 mg/dL and 17.19±3.22 mg/dL and the mean absolute error (MAE) was 21.96±4.67 mg/dL and 12.58±2.34 mg/dL for PH=60 and, 30 min respectively on the same clinical dataset. It was observed that inclusion of physical activity leads to improved glucose forecasting accuracy. Furthermore, all these results were obtained by training the model on only 8 days of clinical data of a single patient, followed by testing on clinical data on the following days. The results indicate that training on a single patient data may lead to better <em>personalisation</em> and better glucose forecasting results compared to existing works.</div></div>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":"132 ","pages":"Article 104241"},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Platform for precise, personalised glucose forecasting through continuous glucose and physical activity monitoring and deep learning\",\"authors\":\"Deepjyoti Kalita ,&nbsp;Hrishita Sharma ,&nbsp;Jayanta Kumar Panda ,&nbsp;Khalid B. Mirza\",\"doi\":\"10.1016/j.medengphy.2024.104241\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Emerging research has demonstrated the advantage of continuous glucose monitoring for use in artificial pancreas and diabetes management in general. Recent studies demonstrate that glucose level forecasting using deep learning can help avoid postprandial hyperglycemia (≥ 180 mg/dL) or hypoglycemia (≤70 mg/dL) from delayed or increased insulin dosing in artificial pancreas. In this paper, a novel hybrid deep learning framework with integration of content-based attention learning is presented, to effectively predict the glucose measurements with prediction horizons (PH) = 15, 30 and, 60 minutes for T1D and T2D patients based on past data. We also present a complete cloud-based system and mobile app used for collecting CGM sensor, physical activity data, CHO values and insulin measurements to perform glucose forecasts using the proposed model running on Cloud. This model was validated using clinical data of individual with Type 1 diabetes (OhioT1DM) and individual with Type 2 diabetes. The mean absolute relative difference (MARD) was 12.33±3.15, 7.14±1.76% for PH=60 and, 30 min respectively on OhioT1DM clinical Dataset. The root mean squared error (RMSE) was 29.41±5.92 mg/dL and 17.19±3.22 mg/dL and the mean absolute error (MAE) was 21.96±4.67 mg/dL and 12.58±2.34 mg/dL for PH=60 and, 30 min respectively on the same clinical dataset. It was observed that inclusion of physical activity leads to improved glucose forecasting accuracy. Furthermore, all these results were obtained by training the model on only 8 days of clinical data of a single patient, followed by testing on clinical data on the following days. The results indicate that training on a single patient data may lead to better <em>personalisation</em> and better glucose forecasting results compared to existing works.</div></div>\",\"PeriodicalId\":49836,\"journal\":{\"name\":\"Medical Engineering & Physics\",\"volume\":\"132 \",\"pages\":\"Article 104241\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Engineering & Physics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1350453324001425\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350453324001425","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

新近的研究表明,在人工胰腺和糖尿病管理中使用连续葡萄糖监测具有优势。最近的研究表明,利用深度学习预测葡萄糖水平有助于避免人工胰腺因延迟或增加胰岛素剂量而导致餐后高血糖(≥ 180 mg/dL)或低血糖(≤ 70 mg/dL)。本文介绍了一种新颖的混合深度学习框架,该框架整合了基于内容的注意力学习,可根据过去的数据有效预测 T1D 和 T2D 患者在预测视野(PH)= 15、30 和 60 分钟内的血糖测量值。我们还介绍了一个完整的基于云的系统和移动应用程序,用于收集 CGM 传感器、体力活动数据、CHO 值和胰岛素测量值,从而使用在云上运行的建议模型进行血糖预测。该模型使用 1 型糖尿病患者(OhioT1DM)和 2 型糖尿病患者的临床数据进行了验证。在 OhioT1DM 临床数据集上,PH=60 和 30 分钟的平均绝对相对误差(MARD)分别为 12.33±3.15%和 7.14±1.76%。在同一临床数据集上,PH=60 和 30 分钟的均方根误差(RMSE)分别为 29.41±5.92 mg/dL 和 17.19±3.22 mg/dL,平均绝对误差(MAE)分别为 21.96±4.67 mg/dL 和 12.58±2.34 mg/dL。据观察,加入体育锻炼可提高血糖预测的准确性。此外,所有这些结果都是通过对单个患者 8 天的临床数据进行模型训练,然后对随后几天的临床数据进行测试得出的。结果表明,与现有研究相比,在单个患者数据上进行训练可能会带来更好的个性化和更好的血糖预测结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Platform for precise, personalised glucose forecasting through continuous glucose and physical activity monitoring and deep learning
Emerging research has demonstrated the advantage of continuous glucose monitoring for use in artificial pancreas and diabetes management in general. Recent studies demonstrate that glucose level forecasting using deep learning can help avoid postprandial hyperglycemia (≥ 180 mg/dL) or hypoglycemia (≤70 mg/dL) from delayed or increased insulin dosing in artificial pancreas. In this paper, a novel hybrid deep learning framework with integration of content-based attention learning is presented, to effectively predict the glucose measurements with prediction horizons (PH) = 15, 30 and, 60 minutes for T1D and T2D patients based on past data. We also present a complete cloud-based system and mobile app used for collecting CGM sensor, physical activity data, CHO values and insulin measurements to perform glucose forecasts using the proposed model running on Cloud. This model was validated using clinical data of individual with Type 1 diabetes (OhioT1DM) and individual with Type 2 diabetes. The mean absolute relative difference (MARD) was 12.33±3.15, 7.14±1.76% for PH=60 and, 30 min respectively on OhioT1DM clinical Dataset. The root mean squared error (RMSE) was 29.41±5.92 mg/dL and 17.19±3.22 mg/dL and the mean absolute error (MAE) was 21.96±4.67 mg/dL and 12.58±2.34 mg/dL for PH=60 and, 30 min respectively on the same clinical dataset. It was observed that inclusion of physical activity leads to improved glucose forecasting accuracy. Furthermore, all these results were obtained by training the model on only 8 days of clinical data of a single patient, followed by testing on clinical data on the following days. The results indicate that training on a single patient data may lead to better personalisation and better glucose forecasting results compared to existing works.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
期刊最新文献
Open laminectomy plus posterolateral fusion versus open laminectomy plus transforaminal lumbar interbody fusion surgical approaches for fusing degenerated L4-L5 segment: A comparative finite element study The effect of the length of chimney's protrusion on the hemodynamics of abdominal aorta stent graft after endovascular aneurysm repair Effect of plantar fascia stiffness on plantar windlass mechanism and arch: Finite element method and dual fluoroscopic imaging system verification An in vitro experimental study on the synergistic pathogenicity analysis of pulsatile tinnitus involving venous flow velocity, sigmoid sinus wall dehiscence and sinus malformation Cadaveric validation of markerless tracking using weightbearing computed tomography versus conventional computed tomography imaging techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1