λ波稀疏阵列符号相干与时间反转融合成像方法研究

IF 3.8 2区 物理与天体物理 Q1 ACOUSTICS Ultrasonics Pub Date : 2024-10-11 DOI:10.1016/j.ultras.2024.107489
Liu-Jia Sun, Qing-Bang Han, Cheng Yin, Qi-Lin Jin, Kao Ge
{"title":"λ波稀疏阵列符号相干与时间反转融合成像方法研究","authors":"Liu-Jia Sun,&nbsp;Qing-Bang Han,&nbsp;Cheng Yin,&nbsp;Qi-Lin Jin,&nbsp;Kao Ge","doi":"10.1016/j.ultras.2024.107489","DOIUrl":null,"url":null,"abstract":"<div><div>Time-reversal imaging struggles to detect plate-like structures due to interference from Lamb wave mode conversion and the processing demands, leading to less effective outcomes. This paper proposes a sign coherence factor and time reversal fusion (SCF-TR) imaging method based on amplitude and phase estimation. This method removes the coherence of array signals during signal reversal and refocusing. It reintroduces the sign coherence component to reduce interference from non-target scattered waves and partially overcome the constraints imposed by the Rayleigh criterion. The method allows imaging at a resolution smaller than the wavelength of Lamb and enhances the quality of the resulting images. In addition, a sparse array design utilizing the White Shark Optimisation Algorithm (WSO) is proposed to streamline the SCF-TR calculation process. This design utilizes sparse full matrix data to improve imaging efficiency. The experimental results show that for single blind hole defects, the SCF-TR method improves the array performance metrics and signal-to-noise ratio by 22.46% and 42.50%, respectively, compared to the TR method. For multiple asymmetric blind hole defects, when the defect size exceeds the resolution threshold, SCF-TR accurately reflects the position and morphology of defects smaller than the wavelength. When the defect size is below the resolution threshold, SCF-TR achieves super-resolution imaging. The sparse array designed using the White Shark Optimization algorithm demonstrates good sidelobe characteristics, effectively reducing sidelobe noise without reducing the array aperture. Moreover, the SCF-TR imaging time is reduced by approximately half while maintaining imaging accuracy.</div></div>","PeriodicalId":23522,"journal":{"name":"Ultrasonics","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on the fusion imaging method of sign coherence and time reversal for Lamb wave sparse array\",\"authors\":\"Liu-Jia Sun,&nbsp;Qing-Bang Han,&nbsp;Cheng Yin,&nbsp;Qi-Lin Jin,&nbsp;Kao Ge\",\"doi\":\"10.1016/j.ultras.2024.107489\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Time-reversal imaging struggles to detect plate-like structures due to interference from Lamb wave mode conversion and the processing demands, leading to less effective outcomes. This paper proposes a sign coherence factor and time reversal fusion (SCF-TR) imaging method based on amplitude and phase estimation. This method removes the coherence of array signals during signal reversal and refocusing. It reintroduces the sign coherence component to reduce interference from non-target scattered waves and partially overcome the constraints imposed by the Rayleigh criterion. The method allows imaging at a resolution smaller than the wavelength of Lamb and enhances the quality of the resulting images. In addition, a sparse array design utilizing the White Shark Optimisation Algorithm (WSO) is proposed to streamline the SCF-TR calculation process. This design utilizes sparse full matrix data to improve imaging efficiency. The experimental results show that for single blind hole defects, the SCF-TR method improves the array performance metrics and signal-to-noise ratio by 22.46% and 42.50%, respectively, compared to the TR method. For multiple asymmetric blind hole defects, when the defect size exceeds the resolution threshold, SCF-TR accurately reflects the position and morphology of defects smaller than the wavelength. When the defect size is below the resolution threshold, SCF-TR achieves super-resolution imaging. The sparse array designed using the White Shark Optimization algorithm demonstrates good sidelobe characteristics, effectively reducing sidelobe noise without reducing the array aperture. Moreover, the SCF-TR imaging time is reduced by approximately half while maintaining imaging accuracy.</div></div>\",\"PeriodicalId\":23522,\"journal\":{\"name\":\"Ultrasonics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasonics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0041624X2400252X\",\"RegionNum\":2,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonics","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0041624X2400252X","RegionNum":2,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

由于 Lamb 波模式转换的干扰和处理要求,时间反转成像在检测板状结构方面很吃力,导致效果不佳。本文提出了一种基于振幅和相位估计的符号相干因子和时间反转融合(SCF-TR)成像方法。这种方法能消除信号反转和重新聚焦时阵列信号的相干性。它重新引入了符号相干分量,以减少非目标散射波的干扰,并部分克服了瑞利准则带来的限制。该方法允许在小于 Lamb 波长的分辨率下成像,并提高了所得图像的质量。此外,还提出了一种利用白鲨优化算法(WSO)的稀疏阵列设计,以简化 SCF-TR 计算过程。这种设计利用稀疏全矩阵数据来提高成像效率。实验结果表明,对于单个盲孔缺陷,SCF-TR 方法与 TR 方法相比,阵列性能指标和信噪比分别提高了 22.46% 和 42.50%。对于多个不对称盲孔缺陷,当缺陷尺寸超过分辨率阈值时,SCF-TR 能准确反映小于波长的缺陷的位置和形态。当缺陷尺寸低于分辨率阈值时,SCF-TR 可实现超分辨率成像。利用白鲨优化算法设计的稀疏阵列具有良好的侧叶特性,能在不减小阵列孔径的情况下有效降低侧叶噪声。此外,在保持成像精度的同时,SCF-TR 的成像时间缩短了约一半。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Research on the fusion imaging method of sign coherence and time reversal for Lamb wave sparse array
Time-reversal imaging struggles to detect plate-like structures due to interference from Lamb wave mode conversion and the processing demands, leading to less effective outcomes. This paper proposes a sign coherence factor and time reversal fusion (SCF-TR) imaging method based on amplitude and phase estimation. This method removes the coherence of array signals during signal reversal and refocusing. It reintroduces the sign coherence component to reduce interference from non-target scattered waves and partially overcome the constraints imposed by the Rayleigh criterion. The method allows imaging at a resolution smaller than the wavelength of Lamb and enhances the quality of the resulting images. In addition, a sparse array design utilizing the White Shark Optimisation Algorithm (WSO) is proposed to streamline the SCF-TR calculation process. This design utilizes sparse full matrix data to improve imaging efficiency. The experimental results show that for single blind hole defects, the SCF-TR method improves the array performance metrics and signal-to-noise ratio by 22.46% and 42.50%, respectively, compared to the TR method. For multiple asymmetric blind hole defects, when the defect size exceeds the resolution threshold, SCF-TR accurately reflects the position and morphology of defects smaller than the wavelength. When the defect size is below the resolution threshold, SCF-TR achieves super-resolution imaging. The sparse array designed using the White Shark Optimization algorithm demonstrates good sidelobe characteristics, effectively reducing sidelobe noise without reducing the array aperture. Moreover, the SCF-TR imaging time is reduced by approximately half while maintaining imaging accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasonics
Ultrasonics 医学-核医学
CiteScore
7.60
自引率
19.00%
发文量
186
审稿时长
3.9 months
期刊介绍: Ultrasonics is the only internationally established journal which covers the entire field of ultrasound research and technology and all its many applications. Ultrasonics contains a variety of sections to keep readers fully informed and up-to-date on the whole spectrum of research and development throughout the world. Ultrasonics publishes papers of exceptional quality and of relevance to both academia and industry. Manuscripts in which ultrasonics is a central issue and not simply an incidental tool or minor issue, are welcomed. As well as top quality original research papers and review articles by world renowned experts, Ultrasonics also regularly features short communications, a calendar of forthcoming events and special issues dedicated to topical subjects.
期刊最新文献
Band edge modulation for high-performance LL-SAW resonators on LiNbO3/SiC by introducing an ultra-thin intermediate oxide layer. Low-intensity pulsed ultrasound reduces oxidative and endoplasmic reticulum stress in motor neuron cells RFImageNet framework for segmentation of ultrasound images with spectra-augmented radiofrequency signals Ultrasonic backscattering measurement of hardness gradient distribution in polycrystalline materials Simulation and experimentation of nonlinear Rayleigh wave inspection of fatigue surface microcracks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1