Minsu Park, Chan-Hyeong Lee, Hyowoong Noh, Geeyoon Kang, Junyeong Lee, Ju-Hyun Bae, Hyeri Moon, Jonghoo Park, Seongho Kong, Moon-Chang Baek, Hongsik Park
{"title":"用于直接从血浆中快速诊断癌症的高精度细胞外微粒分离分析集成平台。","authors":"Minsu Park, Chan-Hyeong Lee, Hyowoong Noh, Geeyoon Kang, Junyeong Lee, Ju-Hyun Bae, Hyeri Moon, Jonghoo Park, Seongho Kong, Moon-Chang Baek, Hongsik Park","doi":"10.1016/j.bios.2024.116863","DOIUrl":null,"url":null,"abstract":"<p><p>Cancer-derived small extracellular vesicles (sEVs) in body fluids hold promise as biomarkers for cancer diagnosis. For sEV-based liquid biopsy, isolation of sEVs with a high-purity and cancer-sEV detection with an extremely high sensitivity are essential because body fluids include much higher density of normal-cell-derived sEVs and other biomolecules and bioparticles. Here, we propose an isolation-analysis-integrated cancer-diagnosis platform based on dielectrophoresis(DEP)-ELISA technique which enables a three orders of magnitude higher sensitivity over conventional ELISA method and direct cancer diagnosis from blood plasma with high accuracy. The limit of detection (LOD) for sEVs in human plasma was as low as 10<sup>4</sup> sEVs/mL without a time-consuming and low-yield sEV isolation and purification process. The capability of this platform was validated by monitoring mice with cancer cell inoculation and assessing the effect of cancer-sEV-inhibiting drug. Using the developed sEV-based liquid biopsy, we diagnosed clinical samples from healthy donors (N = 39) and cancer patients (N = 90). The diagnostic accuracy was 94.2%, 98.6%, and 91.3% for breast, colon, and lung cancers, respectively. This integrated sEV isolation and analysis platform could be applied for high-sensitivity biomarker profiling and sEV-based liquid biopsy.</p>","PeriodicalId":10,"journal":{"name":"ACS Central Science","volume":null,"pages":null},"PeriodicalIF":12.7000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-precision extracellular-vesicle isolation-analysis integrated platform for rapid cancer diagnosis directly from blood plasma.\",\"authors\":\"Minsu Park, Chan-Hyeong Lee, Hyowoong Noh, Geeyoon Kang, Junyeong Lee, Ju-Hyun Bae, Hyeri Moon, Jonghoo Park, Seongho Kong, Moon-Chang Baek, Hongsik Park\",\"doi\":\"10.1016/j.bios.2024.116863\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Cancer-derived small extracellular vesicles (sEVs) in body fluids hold promise as biomarkers for cancer diagnosis. For sEV-based liquid biopsy, isolation of sEVs with a high-purity and cancer-sEV detection with an extremely high sensitivity are essential because body fluids include much higher density of normal-cell-derived sEVs and other biomolecules and bioparticles. Here, we propose an isolation-analysis-integrated cancer-diagnosis platform based on dielectrophoresis(DEP)-ELISA technique which enables a three orders of magnitude higher sensitivity over conventional ELISA method and direct cancer diagnosis from blood plasma with high accuracy. The limit of detection (LOD) for sEVs in human plasma was as low as 10<sup>4</sup> sEVs/mL without a time-consuming and low-yield sEV isolation and purification process. The capability of this platform was validated by monitoring mice with cancer cell inoculation and assessing the effect of cancer-sEV-inhibiting drug. Using the developed sEV-based liquid biopsy, we diagnosed clinical samples from healthy donors (N = 39) and cancer patients (N = 90). The diagnostic accuracy was 94.2%, 98.6%, and 91.3% for breast, colon, and lung cancers, respectively. This integrated sEV isolation and analysis platform could be applied for high-sensitivity biomarker profiling and sEV-based liquid biopsy.</p>\",\"PeriodicalId\":10,\"journal\":{\"name\":\"ACS Central Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":12.7000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Central Science\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://doi.org/10.1016/j.bios.2024.116863\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Central Science","FirstCategoryId":"1","ListUrlMain":"https://doi.org/10.1016/j.bios.2024.116863","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
体液中的癌症衍生小细胞外囊泡(sEVs)有望成为癌症诊断的生物标记物。对于基于 sEV 的液体活检来说,高纯度的 sEV 分离和极高灵敏度的癌症-sEV 检测至关重要,因为体液中包含的正常细胞衍生的 sEV 以及其他生物大分子和生物颗粒的密度要高得多。在此,我们提出了一种基于介质电泳(DEP)-ELISA 技术的分离-分析-癌症诊断一体化平台,其灵敏度比传统的 ELISA 方法高出三个数量级,可直接从血浆中进行高精度的癌症诊断。无需耗时、低产的 sEV 分离和纯化过程,人体血浆中 sEV 的检测限(LOD)低至 104 sEVs/mL。通过监测小鼠的癌细胞接种情况和评估抑制癌症 sEV 药物的效果,验证了该平台的能力。利用开发的基于 sEV 的液体活检技术,我们对来自健康供体(39 人)和癌症患者(90 人)的临床样本进行了诊断。对乳腺癌、结肠癌和肺癌的诊断准确率分别为 94.2%、98.6% 和 91.3%。这种集成的 sEV 分离和分析平台可用于高灵敏度生物标志物分析和基于 sEV 的液体活检。
High-precision extracellular-vesicle isolation-analysis integrated platform for rapid cancer diagnosis directly from blood plasma.
Cancer-derived small extracellular vesicles (sEVs) in body fluids hold promise as biomarkers for cancer diagnosis. For sEV-based liquid biopsy, isolation of sEVs with a high-purity and cancer-sEV detection with an extremely high sensitivity are essential because body fluids include much higher density of normal-cell-derived sEVs and other biomolecules and bioparticles. Here, we propose an isolation-analysis-integrated cancer-diagnosis platform based on dielectrophoresis(DEP)-ELISA technique which enables a three orders of magnitude higher sensitivity over conventional ELISA method and direct cancer diagnosis from blood plasma with high accuracy. The limit of detection (LOD) for sEVs in human plasma was as low as 104 sEVs/mL without a time-consuming and low-yield sEV isolation and purification process. The capability of this platform was validated by monitoring mice with cancer cell inoculation and assessing the effect of cancer-sEV-inhibiting drug. Using the developed sEV-based liquid biopsy, we diagnosed clinical samples from healthy donors (N = 39) and cancer patients (N = 90). The diagnostic accuracy was 94.2%, 98.6%, and 91.3% for breast, colon, and lung cancers, respectively. This integrated sEV isolation and analysis platform could be applied for high-sensitivity biomarker profiling and sEV-based liquid biopsy.
期刊介绍:
ACS Central Science publishes significant primary reports on research in chemistry and allied fields where chemical approaches are pivotal. As the first fully open-access journal by the American Chemical Society, it covers compelling and important contributions to the broad chemistry and scientific community. "Central science," a term popularized nearly 40 years ago, emphasizes chemistry's central role in connecting physical and life sciences, and fundamental sciences with applied disciplines like medicine and engineering. The journal focuses on exceptional quality articles, addressing advances in fundamental chemistry and interdisciplinary research.