{"title":"基于模型的尺寸无损检测(从少量 X 射线射线照片中得出):应用于金属涡轮叶片壁厚评估","authors":"Cédric Fragnaud ,&nbsp;Clément Remacha ,&nbsp;Julián Betancur ,&nbsp;Stéphane Roux","doi":"10.1016/j.precisioneng.2024.10.002","DOIUrl":null,"url":null,"abstract":"<div><div>The extraction of 3D dimensional measurements based on a <em>limited</em> number of 2D X-ray radiographs of a part would offer a significant speed-up of quality control procedures in industry. However, there are challenges with respect to both measurements and uncertainties. This work addresses these challenges by creating an estimated numerical model of the imaged part on which dimensional measurements can be made. The numerical model is chosen as a parametric deformable model that encodes the expected shape variability of the parts resulting from the manufacturing process. The parameters and uncertainties of the numerical model of the imaged part are estimated by the registration of the computed projections of the model and the observed radiographs without the need of any segmentation. The registration requires the model, the initial parameters, and the observed radiographs. The proposed approach is applied to the inspection of turbine blades manufactured by investment casting, and in particular to the measurement of their wall thickness, which is a critical control. The deformable model consists in partitioning the inner ceramic core into multiple subparts, which may undergo a rigid body motion with respect to the master die. Wall thickness measurements are determined from the estimation of these rigid body motions. To assess the reliability of the proposed procedure, a repeatability study is performed. In addition, wall thickness measurements were compared to corresponding measurements from the surface of the metal boundary obtained by X-ray computed tomography. This surface was determined from a reconstructed tomogram using commercial software. Both analyses show that such measurements are reliable and efficient. Furthermore, residual differences between captured and computed projections reveal localized shape deviations from the CAD model, meaning that despite localized model errors, the approach is operable.</div></div>","PeriodicalId":54589,"journal":{"name":"Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology","volume":"91 ","pages":"Pages 536-545"},"PeriodicalIF":3.5000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Model-based dimensional NDE from few X-ray radiographs: Application to the evaluation of wall thickness in metallic turbine blades\",\"authors\":\"Cédric Fragnaud ,&nbsp;Clément Remacha ,&nbsp;Julián Betancur ,&nbsp;Stéphane Roux\",\"doi\":\"10.1016/j.precisioneng.2024.10.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The extraction of 3D dimensional measurements based on a <em>limited</em> number of 2D X-ray radiographs of a part would offer a significant speed-up of quality control procedures in industry. However, there are challenges with respect to both measurements and uncertainties. This work addresses these challenges by creating an estimated numerical model of the imaged part on which dimensional measurements can be made. The numerical model is chosen as a parametric deformable model that encodes the expected shape variability of the parts resulting from the manufacturing process. The parameters and uncertainties of the numerical model of the imaged part are estimated by the registration of the computed projections of the model and the observed radiographs without the need of any segmentation. The registration requires the model, the initial parameters, and the observed radiographs. The proposed approach is applied to the inspection of turbine blades manufactured by investment casting, and in particular to the measurement of their wall thickness, which is a critical control. The deformable model consists in partitioning the inner ceramic core into multiple subparts, which may undergo a rigid body motion with respect to the master die. Wall thickness measurements are determined from the estimation of these rigid body motions. To assess the reliability of the proposed procedure, a repeatability study is performed. In addition, wall thickness measurements were compared to corresponding measurements from the surface of the metal boundary obtained by X-ray computed tomography. This surface was determined from a reconstructed tomogram using commercial software. Both analyses show that such measurements are reliable and efficient. Furthermore, residual differences between captured and computed projections reveal localized shape deviations from the CAD model, meaning that despite localized model errors, the approach is operable.</div></div>\",\"PeriodicalId\":54589,\"journal\":{\"name\":\"Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology\",\"volume\":\"91 \",\"pages\":\"Pages 536-545\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0141635924002290\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MANUFACTURING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141635924002290","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

摘要

根据数量有限的部件二维 X 射线照片提取三维尺寸测量值,将大大加快工业质量控制程序的速度。然而,在测量和不确定性方面都存在挑战。为了应对这些挑战,这项工作创建了一个成像部件的估计数字模型,并在此基础上进行尺寸测量。数值模型被选为参数化可变形模型,该模型可对制造过程中产生的零件预期形状变化进行编码。成像部件数值模型的参数和不确定性是通过模型的计算投影与观察到的射线照片的配准来估算的,无需进行任何分割。注册需要模型、初始参数和观察到的射线照片。所提出的方法被应用于通过熔模铸造法制造的涡轮叶片的检测,特别是其壁厚的测量,这是一项关键控制。可变形模型包括将内部陶瓷芯分成多个子部分,这些子部分可相对于主模进行刚体运动。壁厚测量是通过对这些刚体运动的估计来确定的。为了评估所建议程序的可靠性,进行了重复性研究。此外,还将壁厚测量值与通过 X 射线计算机断层扫描获得的金属边界表面的相应测量值进行了比较。该表面是使用商业软件通过重建断层图确定的。这两项分析表明,这种测量方法既可靠又高效。此外,捕获投影和计算投影之间的残差显示了局部形状与 CAD 模型的偏差,这意味着尽管存在局部模型误差,但这种方法是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Model-based dimensional NDE from few X-ray radiographs: Application to the evaluation of wall thickness in metallic turbine blades
The extraction of 3D dimensional measurements based on a limited number of 2D X-ray radiographs of a part would offer a significant speed-up of quality control procedures in industry. However, there are challenges with respect to both measurements and uncertainties. This work addresses these challenges by creating an estimated numerical model of the imaged part on which dimensional measurements can be made. The numerical model is chosen as a parametric deformable model that encodes the expected shape variability of the parts resulting from the manufacturing process. The parameters and uncertainties of the numerical model of the imaged part are estimated by the registration of the computed projections of the model and the observed radiographs without the need of any segmentation. The registration requires the model, the initial parameters, and the observed radiographs. The proposed approach is applied to the inspection of turbine blades manufactured by investment casting, and in particular to the measurement of their wall thickness, which is a critical control. The deformable model consists in partitioning the inner ceramic core into multiple subparts, which may undergo a rigid body motion with respect to the master die. Wall thickness measurements are determined from the estimation of these rigid body motions. To assess the reliability of the proposed procedure, a repeatability study is performed. In addition, wall thickness measurements were compared to corresponding measurements from the surface of the metal boundary obtained by X-ray computed tomography. This surface was determined from a reconstructed tomogram using commercial software. Both analyses show that such measurements are reliable and efficient. Furthermore, residual differences between captured and computed projections reveal localized shape deviations from the CAD model, meaning that despite localized model errors, the approach is operable.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.40
自引率
5.60%
发文量
177
审稿时长
46 days
期刊介绍: Precision Engineering - Journal of the International Societies for Precision Engineering and Nanotechnology is devoted to the multidisciplinary study and practice of high accuracy engineering, metrology, and manufacturing. The journal takes an integrated approach to all subjects related to research, design, manufacture, performance validation, and application of high precision machines, instruments, and components, including fundamental and applied research and development in manufacturing processes, fabrication technology, and advanced measurement science. The scope includes precision-engineered systems and supporting metrology over the full range of length scales, from atom-based nanotechnology and advanced lithographic technology to large-scale systems, including optical and radio telescopes and macrometrology.
期刊最新文献
Distance deviation sensitivity on null test of convex hyperboloid mirrors with large relative aperture Stiffness model for pneumatic spring with air-diaphragm coupling effect Rapid non-contact measurement of distance between two pins of flexspline in harmonic reducers based on standard/actual parts comparison Based on domain adversarial neural network with multiple loss collaborative optimization for milling tool wear state monitoring under different machining conditions Fabrication of angle-gradient echelle grating on metallic glass using shaped vibration cutting with time-varying trajectory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1