带储能的等效系统频率响应模型

IF 3.3 3区 工程技术 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC Electric Power Systems Research Pub Date : 2024-11-09 DOI:10.1016/j.epsr.2024.111211
Jinjia Zhang , Ying Xue , Yuan Tang , Yiping Chen , Meng Chen , Xin He , Siqi Lin
{"title":"带储能的等效系统频率响应模型","authors":"Jinjia Zhang ,&nbsp;Ying Xue ,&nbsp;Yuan Tang ,&nbsp;Yiping Chen ,&nbsp;Meng Chen ,&nbsp;Xin He ,&nbsp;Siqi Lin","doi":"10.1016/j.epsr.2024.111211","DOIUrl":null,"url":null,"abstract":"<div><div>Providing Frequency Response (FR) using energy storage system (ESS) has been adopted in power systems worldwide to reduce the maximum frequency deviation. This paper presents a new equivalent system frequency response model with ESS. The model can be conveniently used to assess the system frequency nadir and calculate the capacity and equivalent droop of storage considering the maximum frequency deviation in a synchronous generator (SG) dominated system. Unlike existing calculation methods based on control strategies such as fuzzy-logic, robust control, data-driving control and predictive algorithm, the proposed method (i) uses the equivalent capacity and equivalent droop to describe the FR of SG and ESS, thereby avoids the difficulty in solving high-order FR model and (ii) does not need the control strategy of SGs in the network. Therefore, the proposed method provides a simple yet systematic method in calculating the capacity and equivalent droop of ESS. The effectiveness of the proposed method is demonstrated using the four-generator two-area (4G2A) system with 0 %, 25 % and 50 % penetration of renewable resources and different types of SGs (hydraulic and steam SG) based on the given maximum frequency deviation..</div></div>","PeriodicalId":50547,"journal":{"name":"Electric Power Systems Research","volume":"239 ","pages":"Article 111211"},"PeriodicalIF":3.3000,"publicationDate":"2024-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Equivalent system frequency response model with energy storage\",\"authors\":\"Jinjia Zhang ,&nbsp;Ying Xue ,&nbsp;Yuan Tang ,&nbsp;Yiping Chen ,&nbsp;Meng Chen ,&nbsp;Xin He ,&nbsp;Siqi Lin\",\"doi\":\"10.1016/j.epsr.2024.111211\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Providing Frequency Response (FR) using energy storage system (ESS) has been adopted in power systems worldwide to reduce the maximum frequency deviation. This paper presents a new equivalent system frequency response model with ESS. The model can be conveniently used to assess the system frequency nadir and calculate the capacity and equivalent droop of storage considering the maximum frequency deviation in a synchronous generator (SG) dominated system. Unlike existing calculation methods based on control strategies such as fuzzy-logic, robust control, data-driving control and predictive algorithm, the proposed method (i) uses the equivalent capacity and equivalent droop to describe the FR of SG and ESS, thereby avoids the difficulty in solving high-order FR model and (ii) does not need the control strategy of SGs in the network. Therefore, the proposed method provides a simple yet systematic method in calculating the capacity and equivalent droop of ESS. The effectiveness of the proposed method is demonstrated using the four-generator two-area (4G2A) system with 0 %, 25 % and 50 % penetration of renewable resources and different types of SGs (hydraulic and steam SG) based on the given maximum frequency deviation..</div></div>\",\"PeriodicalId\":50547,\"journal\":{\"name\":\"Electric Power Systems Research\",\"volume\":\"239 \",\"pages\":\"Article 111211\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2024-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electric Power Systems Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0378779624010976\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electric Power Systems Research","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378779624010976","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

世界各地的电力系统都采用储能系统(ESS)提供频率响应(FR),以减少最大频率偏差。本文提出了一种带有 ESS 的新等效系统频率响应模型。考虑到同步发电机(SG)主导系统中的最大频率偏差,该模型可方便地用于评估系统频率低点,并计算储能容量和等效垂度。与现有的基于模糊逻辑、鲁棒控制、数据驱动控制和预测算法等控制策略的计算方法不同,所提出的方法(i) 使用等效容量和等效垂度来描述 SG 和 ESS 的故障频率,从而避免了求解高阶故障频率模型的困难,(ii) 不需要网络中 SG 的控制策略。因此,所提出的方法为计算 ESS 容量和等效垂度提供了一种简单而系统的方法。基于给定的最大频率偏差,使用可再生资源渗透率为 0%、25% 和 50% 的四发电机两区域 (4G2A) 系统和不同类型的 SG(水力和蒸汽 SG),证明了所提方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Equivalent system frequency response model with energy storage
Providing Frequency Response (FR) using energy storage system (ESS) has been adopted in power systems worldwide to reduce the maximum frequency deviation. This paper presents a new equivalent system frequency response model with ESS. The model can be conveniently used to assess the system frequency nadir and calculate the capacity and equivalent droop of storage considering the maximum frequency deviation in a synchronous generator (SG) dominated system. Unlike existing calculation methods based on control strategies such as fuzzy-logic, robust control, data-driving control and predictive algorithm, the proposed method (i) uses the equivalent capacity and equivalent droop to describe the FR of SG and ESS, thereby avoids the difficulty in solving high-order FR model and (ii) does not need the control strategy of SGs in the network. Therefore, the proposed method provides a simple yet systematic method in calculating the capacity and equivalent droop of ESS. The effectiveness of the proposed method is demonstrated using the four-generator two-area (4G2A) system with 0 %, 25 % and 50 % penetration of renewable resources and different types of SGs (hydraulic and steam SG) based on the given maximum frequency deviation..
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electric Power Systems Research
Electric Power Systems Research 工程技术-工程:电子与电气
CiteScore
7.50
自引率
17.90%
发文量
963
审稿时长
3.8 months
期刊介绍: Electric Power Systems Research is an international medium for the publication of original papers concerned with the generation, transmission, distribution and utilization of electrical energy. The journal aims at presenting important results of work in this field, whether in the form of applied research, development of new procedures or components, orginal application of existing knowledge or new designapproaches. The scope of Electric Power Systems Research is broad, encompassing all aspects of electric power systems. The following list of topics is not intended to be exhaustive, but rather to indicate topics that fall within the journal purview. • Generation techniques ranging from advances in conventional electromechanical methods, through nuclear power generation, to renewable energy generation. • Transmission, spanning the broad area from UHV (ac and dc) to network operation and protection, line routing and design. • Substation work: equipment design, protection and control systems. • Distribution techniques, equipment development, and smart grids. • The utilization area from energy efficiency to distributed load levelling techniques. • Systems studies including control techniques, planning, optimization methods, stability, security assessment and insulation coordination.
期刊最新文献
Investigation of GLM detections of negative continuing currents observed by high-speed video and narrow-band 777 nm photometer Business and pricing models for smart energy at building level: A Review Enhanced resilience in smart grids: A neural network-based detection of data integrity attacks using improved war strategy optimization Improved electrogeometric model for shielding failure evaluation of double-circuit UHVAC transmission lines based on leader propagation simulations Demand flexibility in hydrogen production by incorporating electrical and physical parameters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1