静脉流速、乙状窦壁开裂和窦畸形对搏动性耳鸣协同致病性分析的体外实验研究

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL Medical Engineering & Physics Pub Date : 2024-11-19 DOI:10.1016/j.medengphy.2024.104257
Shan Tian , Lanyue Chen , Chao Huang , Zhaohui Liu , Lizhen Wang , Yubo Fan
{"title":"静脉流速、乙状窦壁开裂和窦畸形对搏动性耳鸣协同致病性分析的体外实验研究","authors":"Shan Tian ,&nbsp;Lanyue Chen ,&nbsp;Chao Huang ,&nbsp;Zhaohui Liu ,&nbsp;Lizhen Wang ,&nbsp;Yubo Fan","doi":"10.1016/j.medengphy.2024.104257","DOIUrl":null,"url":null,"abstract":"<div><div>Pulsatile tinnitus (PT) is synchronous with patients’ heartbeat, with various reported intracranial etiologies. Sigmoid sinus wall dehiscence (SSWD), sinus malformation and high venous flow velocity were common marks of PT and were generally treated as independent etiology in clinic, but their coupling effect remains unclear. This study aimed to investigate the synergistic pathogenicity of these etiologies. The generation and propagation of venous sound was simulated by in vitro experiment. The entity models of sinus vessel, sinus wall and temporal bone cavity were 3D-printed using resin based on CT imaging. Pulsatile venous flow was generated through sinus lumen, with five velocity levels. Venous sound was collected and analyzed. It was found that pressure and pulsation of venous sound were determined by the coupling of three etiology conditions. Low velocity would not induce pulsatile sound anyway. Sub-high or higher velocity induced mild pulsatile sound coupling with normal sinus and wall. Medium or higher velocity induced moderate pulsatile sound coupling with SSWD and normal sinus. Sub-low or higher velocity induced moderate or severe pulsatile sound coupling with SSWD and sinus malformation. In conclusion, PT diagnosis should include the three investigated etiologies due to their contribution to amplifying venous sound. Among the three etiologies, SSWD exhibits the highest pathogenicity, while high venous flow velocity may reduce the effectiveness of SS wall reconstruction, and sinus malformation may exacerbate the intensity of tinnitus induced by SSWD.</div></div>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":"134 ","pages":"Article 104257"},"PeriodicalIF":1.7000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An in vitro experimental study on the synergistic pathogenicity analysis of pulsatile tinnitus involving venous flow velocity, sigmoid sinus wall dehiscence and sinus malformation\",\"authors\":\"Shan Tian ,&nbsp;Lanyue Chen ,&nbsp;Chao Huang ,&nbsp;Zhaohui Liu ,&nbsp;Lizhen Wang ,&nbsp;Yubo Fan\",\"doi\":\"10.1016/j.medengphy.2024.104257\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Pulsatile tinnitus (PT) is synchronous with patients’ heartbeat, with various reported intracranial etiologies. Sigmoid sinus wall dehiscence (SSWD), sinus malformation and high venous flow velocity were common marks of PT and were generally treated as independent etiology in clinic, but their coupling effect remains unclear. This study aimed to investigate the synergistic pathogenicity of these etiologies. The generation and propagation of venous sound was simulated by in vitro experiment. The entity models of sinus vessel, sinus wall and temporal bone cavity were 3D-printed using resin based on CT imaging. Pulsatile venous flow was generated through sinus lumen, with five velocity levels. Venous sound was collected and analyzed. It was found that pressure and pulsation of venous sound were determined by the coupling of three etiology conditions. Low velocity would not induce pulsatile sound anyway. Sub-high or higher velocity induced mild pulsatile sound coupling with normal sinus and wall. Medium or higher velocity induced moderate pulsatile sound coupling with SSWD and normal sinus. Sub-low or higher velocity induced moderate or severe pulsatile sound coupling with SSWD and sinus malformation. In conclusion, PT diagnosis should include the three investigated etiologies due to their contribution to amplifying venous sound. Among the three etiologies, SSWD exhibits the highest pathogenicity, while high venous flow velocity may reduce the effectiveness of SS wall reconstruction, and sinus malformation may exacerbate the intensity of tinnitus induced by SSWD.</div></div>\",\"PeriodicalId\":49836,\"journal\":{\"name\":\"Medical Engineering & Physics\",\"volume\":\"134 \",\"pages\":\"Article 104257\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Engineering & Physics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1350453324001589\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350453324001589","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

搏动性耳鸣(PT)与患者的心跳同步,有多种颅内病因报道。乙状窦壁开裂(SSWD)、窦畸形和静脉流速过高是 PT 的常见标志,临床上通常将其作为独立病因处理,但其耦合效应仍不明确。本研究旨在探讨这些病因的协同致病性。通过体外实验模拟了静脉声的产生和传播。根据 CT 成像,用树脂三维打印了窦血管、窦壁和颞骨腔的实体模型。窦腔内产生了五级速度的脉动静脉流。收集并分析静脉声。结果发现,静脉声的压力和搏动是由三种病因条件耦合决定的。低速度无论如何都不会引起搏动性声音。次高速度或更高速度会引起与正常静脉窦和静脉壁耦合的轻微搏动声。中等或更高的速度会引起与 SSWD 和正常窦的中度搏动声耦合。次低或更高的速度引起中度或严重的搏动声耦合,伴有 SSWD 和窦畸形。总之,PT 诊断应包括所研究的三种病因,因为它们都有助于放大静脉声。在这三种病因中,SSWD 的致病性最高,而静脉流速过高可能会降低 SS 壁重建的效果,窦畸形可能会加重 SSWD 引起的耳鸣强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An in vitro experimental study on the synergistic pathogenicity analysis of pulsatile tinnitus involving venous flow velocity, sigmoid sinus wall dehiscence and sinus malformation
Pulsatile tinnitus (PT) is synchronous with patients’ heartbeat, with various reported intracranial etiologies. Sigmoid sinus wall dehiscence (SSWD), sinus malformation and high venous flow velocity were common marks of PT and were generally treated as independent etiology in clinic, but their coupling effect remains unclear. This study aimed to investigate the synergistic pathogenicity of these etiologies. The generation and propagation of venous sound was simulated by in vitro experiment. The entity models of sinus vessel, sinus wall and temporal bone cavity were 3D-printed using resin based on CT imaging. Pulsatile venous flow was generated through sinus lumen, with five velocity levels. Venous sound was collected and analyzed. It was found that pressure and pulsation of venous sound were determined by the coupling of three etiology conditions. Low velocity would not induce pulsatile sound anyway. Sub-high or higher velocity induced mild pulsatile sound coupling with normal sinus and wall. Medium or higher velocity induced moderate pulsatile sound coupling with SSWD and normal sinus. Sub-low or higher velocity induced moderate or severe pulsatile sound coupling with SSWD and sinus malformation. In conclusion, PT diagnosis should include the three investigated etiologies due to their contribution to amplifying venous sound. Among the three etiologies, SSWD exhibits the highest pathogenicity, while high venous flow velocity may reduce the effectiveness of SS wall reconstruction, and sinus malformation may exacerbate the intensity of tinnitus induced by SSWD.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
期刊最新文献
Open laminectomy plus posterolateral fusion versus open laminectomy plus transforaminal lumbar interbody fusion surgical approaches for fusing degenerated L4-L5 segment: A comparative finite element study The effect of the length of chimney's protrusion on the hemodynamics of abdominal aorta stent graft after endovascular aneurysm repair Effect of plantar fascia stiffness on plantar windlass mechanism and arch: Finite element method and dual fluoroscopic imaging system verification An in vitro experimental study on the synergistic pathogenicity analysis of pulsatile tinnitus involving venous flow velocity, sigmoid sinus wall dehiscence and sinus malformation Cadaveric validation of markerless tracking using weightbearing computed tomography versus conventional computed tomography imaging techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1