{"title":"利用并联有源电力滤波器和配电静止同步补偿器提高光伏-风能混合并网微电网的电能质量","authors":"Ehsan Akbari, Abbas Zare Ghaleh Seyyedi","doi":"10.1155/etep/9609370","DOIUrl":null,"url":null,"abstract":"<div>\n <p>Unbalanced voltage and harmonics are major challenges in a microgrid. Single- and two-phase loads and short circuit can make unbalanced voltage. Besides, nonlinear loads create harmonic components in the grid. Thus, compensating both of the unbalanced voltage and harmonic distortion is necessary. Otherwise, they could cause low power quality, resonance, and stability issues. The present paper suggests a combination of distribution static synchronous compensator (DSTATCOM) and shunt active power filter (SAPF) to address the unbalanced voltage and harmonic pollution in hybrid grid-connected microgrid. A four-wire distributed static synchronous compensator has been adopted to deal with the negative- and zero-sequence components of the microgrid, extracting these components by using second-order generalized integrator (SOGI). To solve the harmonic issue, a SAPF is presented to dynamic compensation of grid current and voltage harmonic components in addition to DSTATCOM. The SAPF relies on estimating the fundamental frequency positive-sequence component (FFPSC) of the load current by applying the second-order sequence filter (SOSF). Since combining the reference signals of voltage balancer and harmonic eliminating at one controller is impossible, two independent devices are presented. Although both of the equipment have a same conception, their control and operation are different. So, simultaneous incorporation of distributed static synchronous compensator and SAPF for mitigating the unbalancing and distortion in the grid-connected microgrid based on hybrid solar and wind power is the work’s novelty. Some merits of this scheme include simple structure, fast real-time controller, low computational burden, and more effective operation. Robustness and effectiveness of such very simple scheme are evaluated by simulation in MATLAB/Simulink environment. Simulation report demonstrates that the total harmonic distortion (THD) of grid voltage and current decrease well under 1.44% and 2.33%, respectively. Meanwhile, the voltage unbalance factor (VUF) of negative and zero sequence of grid voltage reduces to 1.1% and 0%, respectively.</p>\n </div>","PeriodicalId":51293,"journal":{"name":"International Transactions on Electrical Energy Systems","volume":"2024 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/etep/9609370","citationCount":"0","resultStr":"{\"title\":\"Improving Power Quality of a Hybrid Grid-Connected Photovoltaic–Wind Microgrid Using Shunt Active Power Filter and Distribution Static Synchronous Compensator\",\"authors\":\"Ehsan Akbari, Abbas Zare Ghaleh Seyyedi\",\"doi\":\"10.1155/etep/9609370\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n <p>Unbalanced voltage and harmonics are major challenges in a microgrid. Single- and two-phase loads and short circuit can make unbalanced voltage. Besides, nonlinear loads create harmonic components in the grid. Thus, compensating both of the unbalanced voltage and harmonic distortion is necessary. Otherwise, they could cause low power quality, resonance, and stability issues. The present paper suggests a combination of distribution static synchronous compensator (DSTATCOM) and shunt active power filter (SAPF) to address the unbalanced voltage and harmonic pollution in hybrid grid-connected microgrid. A four-wire distributed static synchronous compensator has been adopted to deal with the negative- and zero-sequence components of the microgrid, extracting these components by using second-order generalized integrator (SOGI). To solve the harmonic issue, a SAPF is presented to dynamic compensation of grid current and voltage harmonic components in addition to DSTATCOM. The SAPF relies on estimating the fundamental frequency positive-sequence component (FFPSC) of the load current by applying the second-order sequence filter (SOSF). Since combining the reference signals of voltage balancer and harmonic eliminating at one controller is impossible, two independent devices are presented. Although both of the equipment have a same conception, their control and operation are different. So, simultaneous incorporation of distributed static synchronous compensator and SAPF for mitigating the unbalancing and distortion in the grid-connected microgrid based on hybrid solar and wind power is the work’s novelty. Some merits of this scheme include simple structure, fast real-time controller, low computational burden, and more effective operation. Robustness and effectiveness of such very simple scheme are evaluated by simulation in MATLAB/Simulink environment. Simulation report demonstrates that the total harmonic distortion (THD) of grid voltage and current decrease well under 1.44% and 2.33%, respectively. Meanwhile, the voltage unbalance factor (VUF) of negative and zero sequence of grid voltage reduces to 1.1% and 0%, respectively.</p>\\n </div>\",\"PeriodicalId\":51293,\"journal\":{\"name\":\"International Transactions on Electrical Energy Systems\",\"volume\":\"2024 1\",\"pages\":\"\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1155/etep/9609370\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Transactions on Electrical Energy Systems\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1155/etep/9609370\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Transactions on Electrical Energy Systems","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/etep/9609370","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Improving Power Quality of a Hybrid Grid-Connected Photovoltaic–Wind Microgrid Using Shunt Active Power Filter and Distribution Static Synchronous Compensator
Unbalanced voltage and harmonics are major challenges in a microgrid. Single- and two-phase loads and short circuit can make unbalanced voltage. Besides, nonlinear loads create harmonic components in the grid. Thus, compensating both of the unbalanced voltage and harmonic distortion is necessary. Otherwise, they could cause low power quality, resonance, and stability issues. The present paper suggests a combination of distribution static synchronous compensator (DSTATCOM) and shunt active power filter (SAPF) to address the unbalanced voltage and harmonic pollution in hybrid grid-connected microgrid. A four-wire distributed static synchronous compensator has been adopted to deal with the negative- and zero-sequence components of the microgrid, extracting these components by using second-order generalized integrator (SOGI). To solve the harmonic issue, a SAPF is presented to dynamic compensation of grid current and voltage harmonic components in addition to DSTATCOM. The SAPF relies on estimating the fundamental frequency positive-sequence component (FFPSC) of the load current by applying the second-order sequence filter (SOSF). Since combining the reference signals of voltage balancer and harmonic eliminating at one controller is impossible, two independent devices are presented. Although both of the equipment have a same conception, their control and operation are different. So, simultaneous incorporation of distributed static synchronous compensator and SAPF for mitigating the unbalancing and distortion in the grid-connected microgrid based on hybrid solar and wind power is the work’s novelty. Some merits of this scheme include simple structure, fast real-time controller, low computational burden, and more effective operation. Robustness and effectiveness of such very simple scheme are evaluated by simulation in MATLAB/Simulink environment. Simulation report demonstrates that the total harmonic distortion (THD) of grid voltage and current decrease well under 1.44% and 2.33%, respectively. Meanwhile, the voltage unbalance factor (VUF) of negative and zero sequence of grid voltage reduces to 1.1% and 0%, respectively.
期刊介绍:
International Transactions on Electrical Energy Systems publishes original research results on key advances in the generation, transmission, and distribution of electrical energy systems. Of particular interest are submissions concerning the modeling, analysis, optimization and control of advanced electric power systems.
Manuscripts on topics of economics, finance, policies, insulation materials, low-voltage power electronics, plasmas, and magnetics will generally not be considered for review.