制作和评估用于超声成像图像质量评估的乳腺组织等效模型。

IF 2.5 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiography Pub Date : 2025-01-01 DOI:10.1016/j.radi.2024.11.023
A.P. Hariyanto , F.F. Mugni , L. Khumaira , A.D. Sensusiati , A.L. Nursela , Suprijanto , K.H. Ng , F. Haryanto , Endarko
{"title":"制作和评估用于超声成像图像质量评估的乳腺组织等效模型。","authors":"A.P. Hariyanto ,&nbsp;F.F. Mugni ,&nbsp;L. Khumaira ,&nbsp;A.D. Sensusiati ,&nbsp;A.L. Nursela ,&nbsp;Suprijanto ,&nbsp;K.H. Ng ,&nbsp;F. Haryanto ,&nbsp;Endarko","doi":"10.1016/j.radi.2024.11.023","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Phantom materials with tissue-equivalent physical properties that require regular evaluation using patented phantoms are essential for medical device quality assurance programs. This study evaluated phantom materials for tissue equivalence and their use in image quality assessment for breast ultrasound scanner performance testing using two custom-made phantoms.</div></div><div><h3>Methods</h3><div>Two types of phantoms were developed: phantoms A and B. Phantom A was made from a base material consisting of polyvinyl chloride-plastisol with the addition of glycerol, whereas phantom B consisted of polyvinyl chloride-plastisol with the addition of graphite. Each phantom had a stiff and soft lesion shaped like a sphere, with a diameter of 1.4 cm. The phantoms were cuboids with dimensions of 10 × 10 cm<sup>2</sup> and a thickness of 5 cm. A series of phantom evaluations was performed, consisting of density, elasticity, acoustic properties, B-mode ultrasound images, and strain ratio.</div></div><div><h3>Results</h3><div>The characterisation results show that background A closely resembles fibroglandular tissue in terms of density and acoustic properties (&lt;5% variation); background B only resembles fibroglandular tissue in terms of density (−1.8% variation). In terms of elasticity, both backgrounds were close to the minimum value of fibroglandular tissue elasticity. The soft lesion on the phantom had a slightly lower density and elasticity than the carcinoma, whereas its acoustic properties (speed of sound and attenuation coefficient) were slightly higher than those of the reference carcinoma. Both phantoms were consistent with the literature in terms of strain ratio, geometric accuracy, lesion detection, and mean pixel value and showed good potential stability over one year.</div></div><div><h3>Conclusion</h3><div>This study successfully described the fabrication and evaluation sequence of a phantom equivalent to breast fibroglandular tissue and its evaluation via ultrasound imaging.</div></div><div><h3>Implications for practice</h3><div>This study offers proprietary information essential for the fabrication of phantoms that can be used for quality assurance and control in ultrasound imaging.</div></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":"31 1","pages":"Pages 254-263"},"PeriodicalIF":2.5000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fabrication and evaluation of breast tissue equivalent phantoms for image quality assessment in ultrasound imaging\",\"authors\":\"A.P. Hariyanto ,&nbsp;F.F. Mugni ,&nbsp;L. Khumaira ,&nbsp;A.D. Sensusiati ,&nbsp;A.L. Nursela ,&nbsp;Suprijanto ,&nbsp;K.H. Ng ,&nbsp;F. Haryanto ,&nbsp;Endarko\",\"doi\":\"10.1016/j.radi.2024.11.023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><div>Phantom materials with tissue-equivalent physical properties that require regular evaluation using patented phantoms are essential for medical device quality assurance programs. This study evaluated phantom materials for tissue equivalence and their use in image quality assessment for breast ultrasound scanner performance testing using two custom-made phantoms.</div></div><div><h3>Methods</h3><div>Two types of phantoms were developed: phantoms A and B. Phantom A was made from a base material consisting of polyvinyl chloride-plastisol with the addition of glycerol, whereas phantom B consisted of polyvinyl chloride-plastisol with the addition of graphite. Each phantom had a stiff and soft lesion shaped like a sphere, with a diameter of 1.4 cm. The phantoms were cuboids with dimensions of 10 × 10 cm<sup>2</sup> and a thickness of 5 cm. A series of phantom evaluations was performed, consisting of density, elasticity, acoustic properties, B-mode ultrasound images, and strain ratio.</div></div><div><h3>Results</h3><div>The characterisation results show that background A closely resembles fibroglandular tissue in terms of density and acoustic properties (&lt;5% variation); background B only resembles fibroglandular tissue in terms of density (−1.8% variation). In terms of elasticity, both backgrounds were close to the minimum value of fibroglandular tissue elasticity. The soft lesion on the phantom had a slightly lower density and elasticity than the carcinoma, whereas its acoustic properties (speed of sound and attenuation coefficient) were slightly higher than those of the reference carcinoma. Both phantoms were consistent with the literature in terms of strain ratio, geometric accuracy, lesion detection, and mean pixel value and showed good potential stability over one year.</div></div><div><h3>Conclusion</h3><div>This study successfully described the fabrication and evaluation sequence of a phantom equivalent to breast fibroglandular tissue and its evaluation via ultrasound imaging.</div></div><div><h3>Implications for practice</h3><div>This study offers proprietary information essential for the fabrication of phantoms that can be used for quality assurance and control in ultrasound imaging.</div></div>\",\"PeriodicalId\":47416,\"journal\":{\"name\":\"Radiography\",\"volume\":\"31 1\",\"pages\":\"Pages 254-263\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1078817424003547\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817424003547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

简介:具有组织等效物理特性的幻影材料需要使用专利幻影进行定期评估,这对于医疗器械质量保证计划至关重要。本研究使用两个定制的假体,评估假体材料在乳腺超声扫描仪性能测试中的组织等效性及其在图像质量评估中的应用。方法:制备了两种类型的幻影:幻影A和幻影B。幻影A是由添加甘油的聚氯乙烯-塑料溶胶组成的基材,而幻影B是由添加石墨的聚氯乙烯-塑料溶胶组成的基材。每个幻肢都有一个坚硬和柔软的病变,形状像一个球体,直径为1.4厘米。这些幻影是长方体,尺寸为10 × 10平方厘米,厚度为5厘米。我们对假体进行了一系列的评估,包括密度、弹性、声学性能、b超图像和应变比。结果:表征结果显示背景A在密度和声学特性上与纤维腺组织非常相似(结论:本研究成功地描述了乳腺纤维腺组织等效假体的制作和评估顺序,并通过超声成像对其进行了评估。实践意义:本研究为超声成像中用于质量保证和控制的幻像的制造提供了必要的专有信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fabrication and evaluation of breast tissue equivalent phantoms for image quality assessment in ultrasound imaging

Introduction

Phantom materials with tissue-equivalent physical properties that require regular evaluation using patented phantoms are essential for medical device quality assurance programs. This study evaluated phantom materials for tissue equivalence and their use in image quality assessment for breast ultrasound scanner performance testing using two custom-made phantoms.

Methods

Two types of phantoms were developed: phantoms A and B. Phantom A was made from a base material consisting of polyvinyl chloride-plastisol with the addition of glycerol, whereas phantom B consisted of polyvinyl chloride-plastisol with the addition of graphite. Each phantom had a stiff and soft lesion shaped like a sphere, with a diameter of 1.4 cm. The phantoms were cuboids with dimensions of 10 × 10 cm2 and a thickness of 5 cm. A series of phantom evaluations was performed, consisting of density, elasticity, acoustic properties, B-mode ultrasound images, and strain ratio.

Results

The characterisation results show that background A closely resembles fibroglandular tissue in terms of density and acoustic properties (<5% variation); background B only resembles fibroglandular tissue in terms of density (−1.8% variation). In terms of elasticity, both backgrounds were close to the minimum value of fibroglandular tissue elasticity. The soft lesion on the phantom had a slightly lower density and elasticity than the carcinoma, whereas its acoustic properties (speed of sound and attenuation coefficient) were slightly higher than those of the reference carcinoma. Both phantoms were consistent with the literature in terms of strain ratio, geometric accuracy, lesion detection, and mean pixel value and showed good potential stability over one year.

Conclusion

This study successfully described the fabrication and evaluation sequence of a phantom equivalent to breast fibroglandular tissue and its evaluation via ultrasound imaging.

Implications for practice

This study offers proprietary information essential for the fabrication of phantoms that can be used for quality assurance and control in ultrasound imaging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiography
Radiography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍: Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.
期刊最新文献
Economic, ethical and legal implications of evidence-based practice and continuing professional development in radiography: A narrative review A qualitative exploration of sonographers’ views toward transvaginal ultrasound in Zimbabwe: A barriers and solutions approach User evaluation of clinical simulation-based learning developed by FORCE (Framework for Online Radiographer Clinical Education) "If there was a quick and easy way to participate": The engagement of United Kingdom radiotherapy and diagnostic imaging departments in research strategy. Caring for the deaf and hard-of-hearing patients during magnetic resonance imaging (MRI): A phenomenological study of MRI radiographers' experiences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1