{"title":"聚糖同源物在不同电喷雾模式下的电离特性。","authors":"Nicholas R Allen, Kanwal Jeet, Tolulope Ogunsanya, Ian Ferraro, Nancy Fernandes, Huishan Li, Thaddaeus Webster, Carrie Mason, Anyin Li","doi":"10.1021/jasms.4c00425","DOIUrl":null,"url":null,"abstract":"<p><p>Fluorescence labeled glycan homologous mixtures were quantified using fluorescence and then used to evaluate ionization performances in electrospray ionization at micro, nano, and femto flow modes. nanoESI produced higher (2+ and 3+) charged ions adducted with sodium and calcium. In comparison, femtoESI was found to favor the generation of [M + H]<sup>+</sup> ions against metal adducts, even with nonvolatile salts up to 1 mM for NaCl and 100 μM for CaCl<sub>2</sub>. For labeled glucose homopolymer (GHP) glycans, nanoESI and femtoESI had 0.81 and 3 nM detection limits, respectively. With LC separation and a much higher flow rate, conventional microflow ESI detected all glycans with 10-fold lower concentrations. Overall, nanoESI had the optimum uniformity in the relative ionization efficiency (RIE). When summing up intensities of analyte ions formed with all charge carriers, the RIE of the midsized glycans (10 to 16 glucose units) appear to be uniform (RIE 95%-105%). For the smaller (1-5 glucose units) glycan components, femtoESI provided better uniformity than nanoESI and conventional ESI. For the labeled IgG N-glycans, the impact of chemical structure on the ionization efficiency was revealed by the strong correlation between their RIE trends in different ionization modes.</p>","PeriodicalId":672,"journal":{"name":"Journal of the American Society for Mass Spectrometry","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ionization Characteristics of Glycan Homologues in Various Modes of Electrospray.\",\"authors\":\"Nicholas R Allen, Kanwal Jeet, Tolulope Ogunsanya, Ian Ferraro, Nancy Fernandes, Huishan Li, Thaddaeus Webster, Carrie Mason, Anyin Li\",\"doi\":\"10.1021/jasms.4c00425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fluorescence labeled glycan homologous mixtures were quantified using fluorescence and then used to evaluate ionization performances in electrospray ionization at micro, nano, and femto flow modes. nanoESI produced higher (2+ and 3+) charged ions adducted with sodium and calcium. In comparison, femtoESI was found to favor the generation of [M + H]<sup>+</sup> ions against metal adducts, even with nonvolatile salts up to 1 mM for NaCl and 100 μM for CaCl<sub>2</sub>. For labeled glucose homopolymer (GHP) glycans, nanoESI and femtoESI had 0.81 and 3 nM detection limits, respectively. With LC separation and a much higher flow rate, conventional microflow ESI detected all glycans with 10-fold lower concentrations. Overall, nanoESI had the optimum uniformity in the relative ionization efficiency (RIE). When summing up intensities of analyte ions formed with all charge carriers, the RIE of the midsized glycans (10 to 16 glucose units) appear to be uniform (RIE 95%-105%). For the smaller (1-5 glucose units) glycan components, femtoESI provided better uniformity than nanoESI and conventional ESI. For the labeled IgG N-glycans, the impact of chemical structure on the ionization efficiency was revealed by the strong correlation between their RIE trends in different ionization modes.</p>\",\"PeriodicalId\":672,\"journal\":{\"name\":\"Journal of the American Society for Mass Spectrometry\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the American Society for Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/jasms.4c00425\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the American Society for Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/jasms.4c00425","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

荧光标记的聚糖同源混合物使用荧光定量,然后用于评估在微、纳米和飞飞流模式下电喷雾电离的电离性能。纳米esi产生了与钠和钙内合的更高的(2+和3+)带电离子。相比之下,femtoESI有利于金属加合物生成[M + H]+离子,即使是非挥发性盐高达1 mM (NaCl)和100 μM (CaCl2)。对于标记的葡萄糖均聚物(GHP)聚糖,nanoESI和femtoESI的检出限分别为0.81 nM和3 nM。通过LC分离和更高的流速,传统的微流ESI检测到的多糖浓度降低了10倍。总的来说,纳米esi在相对电离效率(RIE)上具有最佳的均匀性。当对所有载流子形成的分析物离子的强度进行汇总时,中等大小聚糖(10 ~ 16个葡萄糖单位)的RIE似乎是均匀的(RIE 95%-105%)。对于较小的糖组分(1-5葡萄糖单位),飞质ESI比纳米ESI和常规ESI具有更好的均匀性。对于标记的IgG n -聚糖,化学结构对其电离效率的影响体现在它们在不同电离模式下的RIE趋势之间的强相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ionization Characteristics of Glycan Homologues in Various Modes of Electrospray.

Fluorescence labeled glycan homologous mixtures were quantified using fluorescence and then used to evaluate ionization performances in electrospray ionization at micro, nano, and femto flow modes. nanoESI produced higher (2+ and 3+) charged ions adducted with sodium and calcium. In comparison, femtoESI was found to favor the generation of [M + H]+ ions against metal adducts, even with nonvolatile salts up to 1 mM for NaCl and 100 μM for CaCl2. For labeled glucose homopolymer (GHP) glycans, nanoESI and femtoESI had 0.81 and 3 nM detection limits, respectively. With LC separation and a much higher flow rate, conventional microflow ESI detected all glycans with 10-fold lower concentrations. Overall, nanoESI had the optimum uniformity in the relative ionization efficiency (RIE). When summing up intensities of analyte ions formed with all charge carriers, the RIE of the midsized glycans (10 to 16 glucose units) appear to be uniform (RIE 95%-105%). For the smaller (1-5 glucose units) glycan components, femtoESI provided better uniformity than nanoESI and conventional ESI. For the labeled IgG N-glycans, the impact of chemical structure on the ionization efficiency was revealed by the strong correlation between their RIE trends in different ionization modes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.50
自引率
9.40%
发文量
257
审稿时长
1 months
期刊介绍: The Journal of the American Society for Mass Spectrometry presents research papers covering all aspects of mass spectrometry, incorporating coverage of fields of scientific inquiry in which mass spectrometry can play a role. Comprehensive in scope, the journal publishes papers on both fundamentals and applications of mass spectrometry. Fundamental subjects include instrumentation principles, design, and demonstration, structures and chemical properties of gas-phase ions, studies of thermodynamic properties, ion spectroscopy, chemical kinetics, mechanisms of ionization, theories of ion fragmentation, cluster ions, and potential energy surfaces. In addition to full papers, the journal offers Communications, Application Notes, and Accounts and Perspectives
期刊最新文献
Improved LC-MS Detection of Opioids, Amphetamines, and Psychedelics Using TrEnDi. Analysis of Fentanyl and Fentanyl Analogs Using Atmospheric Pressure Chemical Ionization Gas Chromatography-Mass Spectrometry (APCI-GC-MS). Revisiting the Effect of Trypsin Digestion Buffers on Artificial Deamidation. Quantitative MALDI-TOF Mass Spectrometry of Star-Shaped Polylactides Based on Chromatographic Hyphenation. Rapid and Non-Targeted Qualitative and Quantitative Detection of miRNA in Complex Biological Samples Using Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry with a 3-Aminoquinoline and 2',4',6'-Trihydroxyacetophenone Ionic Liquid Matrix.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1