低度血液稀释可改善手术患者的微循环功能。

IF 2.9 4区 医学 Q2 PERIPHERAL VASCULAR DISEASE Microvascular research Pub Date : 2024-12-29 DOI:10.1016/j.mvr.2024.104781
Robert G. Hahn , Katerina Tlapakova , Hana Koudelova , Veronika Knoblochova , David Rehak , Vladimir Cerny , David Astapenko
{"title":"低度血液稀释可改善手术患者的微循环功能。","authors":"Robert G. Hahn ,&nbsp;Katerina Tlapakova ,&nbsp;Hana Koudelova ,&nbsp;Veronika Knoblochova ,&nbsp;David Rehak ,&nbsp;Vladimir Cerny ,&nbsp;David Astapenko","doi":"10.1016/j.mvr.2024.104781","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Excess fluid in the interstitium can adversely affect the microcirculation. We studied how gradual dilution of the blood plasma by crystalloid fluid influences microcirculatory variables and capillary filtration in 20 patients undergoing surgery.</div></div><div><h3>Methods</h3><div>Video recordings of the sublingual mucosal were made on four occasions during the surgery and compared with quasi-measurements of the capillary filtration rate using retrospective volume kinetic data collected over 5–10-minute periods during 262 infusion experiments with crystalloid fluid.</div></div><div><h3>Results</h3><div>The number of crossings (vessel density) increased up to plasma dilution of 15–20 % whereafter it decreased. The proportion of the vessels that were perfused (PPV) decreased and reached a nadir of −15 % at a dilution of 20–30 %. Changes in the number of crossings and the PPV correlated (<em>r</em> = 0.62, <em>P</em> &lt; 0.001) but the curve was displaced so that crossings showed no change when PPV had decreased by approximately 10 %. However, the PPV of vessels with a thickness of ≤25 μm increased or remained constant in the dilution range of up to 20 %. The volume kinetic analysis showed that the capillary filtration was greater than expected from proportionality with the volume expansion up to a plasma dilution of 15 %, the greatest difference (+89 %) being for plasma dilution up to 5 %.</div></div><div><h3>Conclusion</h3><div>Plasma dilution of up to 15 % increased the vessel density, and the capillary filtration increased by more than suggested by the volume expansion. Dilution &gt;15 % had a negative influence on these variables.</div></div>","PeriodicalId":18534,"journal":{"name":"Microvascular research","volume":"158 ","pages":"Article 104781"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Low-grade hemodilution improves the microcirculatory function in surgical patients\",\"authors\":\"Robert G. Hahn ,&nbsp;Katerina Tlapakova ,&nbsp;Hana Koudelova ,&nbsp;Veronika Knoblochova ,&nbsp;David Rehak ,&nbsp;Vladimir Cerny ,&nbsp;David Astapenko\",\"doi\":\"10.1016/j.mvr.2024.104781\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Excess fluid in the interstitium can adversely affect the microcirculation. We studied how gradual dilution of the blood plasma by crystalloid fluid influences microcirculatory variables and capillary filtration in 20 patients undergoing surgery.</div></div><div><h3>Methods</h3><div>Video recordings of the sublingual mucosal were made on four occasions during the surgery and compared with quasi-measurements of the capillary filtration rate using retrospective volume kinetic data collected over 5–10-minute periods during 262 infusion experiments with crystalloid fluid.</div></div><div><h3>Results</h3><div>The number of crossings (vessel density) increased up to plasma dilution of 15–20 % whereafter it decreased. The proportion of the vessels that were perfused (PPV) decreased and reached a nadir of −15 % at a dilution of 20–30 %. Changes in the number of crossings and the PPV correlated (<em>r</em> = 0.62, <em>P</em> &lt; 0.001) but the curve was displaced so that crossings showed no change when PPV had decreased by approximately 10 %. However, the PPV of vessels with a thickness of ≤25 μm increased or remained constant in the dilution range of up to 20 %. The volume kinetic analysis showed that the capillary filtration was greater than expected from proportionality with the volume expansion up to a plasma dilution of 15 %, the greatest difference (+89 %) being for plasma dilution up to 5 %.</div></div><div><h3>Conclusion</h3><div>Plasma dilution of up to 15 % increased the vessel density, and the capillary filtration increased by more than suggested by the volume expansion. Dilution &gt;15 % had a negative influence on these variables.</div></div>\",\"PeriodicalId\":18534,\"journal\":{\"name\":\"Microvascular research\",\"volume\":\"158 \",\"pages\":\"Article 104781\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microvascular research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0026286224001304\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microvascular research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0026286224001304","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

背景:间质中过量的液体会对微循环产生不利影响。我们研究了晶体液体逐渐稀释血浆对20例手术患者微循环变量和毛细血管过滤的影响。方法:术中四次对舌下粘膜进行录像,并与262次结晶液输注实验中5-10分钟内收集的回顾性体积动力学数据的毛细管滤过率准测量结果进行比较。结果:血浆稀释度为15- 20% %时,血管密度增加,稀释度降低。被灌注血管的比例(PPV)下降,在20-30 %的稀释下达到最低点-15 %。结论:血浆稀释度达到15% %时,血管密度增加,毛细血管滤过量增加,其幅度大于体积扩张所提示的幅度。稀释bbb15 %对这些变量有负影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Low-grade hemodilution improves the microcirculatory function in surgical patients

Background

Excess fluid in the interstitium can adversely affect the microcirculation. We studied how gradual dilution of the blood plasma by crystalloid fluid influences microcirculatory variables and capillary filtration in 20 patients undergoing surgery.

Methods

Video recordings of the sublingual mucosal were made on four occasions during the surgery and compared with quasi-measurements of the capillary filtration rate using retrospective volume kinetic data collected over 5–10-minute periods during 262 infusion experiments with crystalloid fluid.

Results

The number of crossings (vessel density) increased up to plasma dilution of 15–20 % whereafter it decreased. The proportion of the vessels that were perfused (PPV) decreased and reached a nadir of −15 % at a dilution of 20–30 %. Changes in the number of crossings and the PPV correlated (r = 0.62, P < 0.001) but the curve was displaced so that crossings showed no change when PPV had decreased by approximately 10 %. However, the PPV of vessels with a thickness of ≤25 μm increased or remained constant in the dilution range of up to 20 %. The volume kinetic analysis showed that the capillary filtration was greater than expected from proportionality with the volume expansion up to a plasma dilution of 15 %, the greatest difference (+89 %) being for plasma dilution up to 5 %.

Conclusion

Plasma dilution of up to 15 % increased the vessel density, and the capillary filtration increased by more than suggested by the volume expansion. Dilution >15 % had a negative influence on these variables.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microvascular research
Microvascular research 医学-外周血管病
CiteScore
6.00
自引率
3.20%
发文量
158
审稿时长
43 days
期刊介绍: Microvascular Research is dedicated to the dissemination of fundamental information related to the microvascular field. Full-length articles presenting the results of original research and brief communications are featured. Research Areas include: • Angiogenesis • Biochemistry • Bioengineering • Biomathematics • Biophysics • Cancer • Circulatory homeostasis • Comparative physiology • Drug delivery • Neuropharmacology • Microvascular pathology • Rheology • Tissue Engineering.
期刊最新文献
Feasibility of a method for measurement of retinal pulse-propagated wave velocity in humans Focal adhesion kinase mediates microvascular leakage and endothelial barrier dysfunction in ischemia-reperfusion injury Editorial Board Sex and age-related day-to-day variability in the skin microcirculation during post-occlusive reactive hyperemia X-ray microtomography imaging enables accurate visualization and quantification of the small-intestinal villi microvasculature – celiac disease as a model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1