Melissa Lynne Martin, Quy Cao, Elaina Luskin, Brian Renner, Lynn Daboul, Carly M O'Donnell, Paulo Rodrigues, John Derbyshire, Christina J Azevedo, Amit Bar-Or, Eduardo Caverzasi, Peter Calabresi, Bruce A C Cree, Léorah Freeman, Roland G Henry, Erin E Longbrake, Jiwon Oh, Nico Papinutto, Daniel Pelletier, Vesna Prchkovska, Marc Ramos, Rohini D Samudralwar, Matthew K Schindler, Elias S Sotirchos, Nancy L Sicotte, Andrew J Solomon, Daniel S Reich, Daniel Ontaneda, Russell T Shinohara, Pascal Sati
{"title":"多中心研究中3T FLAIR*中心静脉征象成像的可靠性","authors":"Melissa Lynne Martin, Quy Cao, Elaina Luskin, Brian Renner, Lynn Daboul, Carly M O'Donnell, Paulo Rodrigues, John Derbyshire, Christina J Azevedo, Amit Bar-Or, Eduardo Caverzasi, Peter Calabresi, Bruce A C Cree, Léorah Freeman, Roland G Henry, Erin E Longbrake, Jiwon Oh, Nico Papinutto, Daniel Pelletier, Vesna Prchkovska, Marc Ramos, Rohini D Samudralwar, Matthew K Schindler, Elias S Sotirchos, Nancy L Sicotte, Andrew J Solomon, Daniel S Reich, Daniel Ontaneda, Russell T Shinohara, Pascal Sati","doi":"10.1111/jon.70011","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>The central vein sign (CVS) is a diagnostic imaging biomarker for multiple sclerosis (MS). FLAIR* is a combined MRI contrast that provides high conspicuity for CVS at 3 Tesla (3T), enabling its sensitive and accurate detection in clinical settings. This study evaluated whether CVS conspicuity of 3T FLAIR* is reliable across imaging sites and MRI vendors and whether gadolinium (Gd) contrast increases CVS conspicuity.</p><p><strong>Methods: </strong>A cross-sectional, multicenter study recruited adults referred for possible diagnosis of MS at 10 sites. FLAIR* contrast was generated using high-resolution T2*-weighted (acquired pre- and post-injection of Gd) and T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) brain images at 3T from two MRI vendors. Lesions and veins were segmented to compute lesion-to-vein contrast-to-noise ratio (CNR<sub>lesion-to-vein</sub>), a quantitative measure of CVS conspicuity. CNR<sub>lesion-to-vein</sub> measures for pre- and post-Gd FLAIR* were compared across sites and vendors.</p><p><strong>Results: </strong>Eighty-seven participants from nine sites were included in the analysis. There was no significant difference in mean CNR<sub>lesion-to-vein</sub> between sites for pre-Gd (p-value = 0.07) or post-Gd (p-value = 0.27) FLAIR*. There were also no significant differences between vendors for pre-Gd (p-value = 0.10) or post-Gd (p-value = 0.31) FLAIR*. Patient-level pairwise differences in CNR<sub>lesion-to-vein</sub> between pre-Gd and post-Gd FLAIR* revealed a significant increase for post-Gd FLAIR* (p-value < 0.001).</p><p><strong>Conclusions: </strong>CVS conspicuity on 3T FLAIR* is consistent across imaging sites and MRI vendors. Moreover, Gd-based contrast agent significantly improved CVS conspicuity on 3T FLAIR*. These findings support the implementation of FLAIR* in clinical settings for MS.</p>","PeriodicalId":16399,"journal":{"name":"Journal of Neuroimaging","volume":"35 1","pages":"e70011"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of Central Vein Sign Imaging With 3T FLAIR* in a Multicenter Study.\",\"authors\":\"Melissa Lynne Martin, Quy Cao, Elaina Luskin, Brian Renner, Lynn Daboul, Carly M O'Donnell, Paulo Rodrigues, John Derbyshire, Christina J Azevedo, Amit Bar-Or, Eduardo Caverzasi, Peter Calabresi, Bruce A C Cree, Léorah Freeman, Roland G Henry, Erin E Longbrake, Jiwon Oh, Nico Papinutto, Daniel Pelletier, Vesna Prchkovska, Marc Ramos, Rohini D Samudralwar, Matthew K Schindler, Elias S Sotirchos, Nancy L Sicotte, Andrew J Solomon, Daniel S Reich, Daniel Ontaneda, Russell T Shinohara, Pascal Sati\",\"doi\":\"10.1111/jon.70011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and purpose: </strong>The central vein sign (CVS) is a diagnostic imaging biomarker for multiple sclerosis (MS). FLAIR* is a combined MRI contrast that provides high conspicuity for CVS at 3 Tesla (3T), enabling its sensitive and accurate detection in clinical settings. This study evaluated whether CVS conspicuity of 3T FLAIR* is reliable across imaging sites and MRI vendors and whether gadolinium (Gd) contrast increases CVS conspicuity.</p><p><strong>Methods: </strong>A cross-sectional, multicenter study recruited adults referred for possible diagnosis of MS at 10 sites. FLAIR* contrast was generated using high-resolution T2*-weighted (acquired pre- and post-injection of Gd) and T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) brain images at 3T from two MRI vendors. Lesions and veins were segmented to compute lesion-to-vein contrast-to-noise ratio (CNR<sub>lesion-to-vein</sub>), a quantitative measure of CVS conspicuity. CNR<sub>lesion-to-vein</sub> measures for pre- and post-Gd FLAIR* were compared across sites and vendors.</p><p><strong>Results: </strong>Eighty-seven participants from nine sites were included in the analysis. There was no significant difference in mean CNR<sub>lesion-to-vein</sub> between sites for pre-Gd (p-value = 0.07) or post-Gd (p-value = 0.27) FLAIR*. There were also no significant differences between vendors for pre-Gd (p-value = 0.10) or post-Gd (p-value = 0.31) FLAIR*. Patient-level pairwise differences in CNR<sub>lesion-to-vein</sub> between pre-Gd and post-Gd FLAIR* revealed a significant increase for post-Gd FLAIR* (p-value < 0.001).</p><p><strong>Conclusions: </strong>CVS conspicuity on 3T FLAIR* is consistent across imaging sites and MRI vendors. Moreover, Gd-based contrast agent significantly improved CVS conspicuity on 3T FLAIR*. These findings support the implementation of FLAIR* in clinical settings for MS.</p>\",\"PeriodicalId\":16399,\"journal\":{\"name\":\"Journal of Neuroimaging\",\"volume\":\"35 1\",\"pages\":\"e70011\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neuroimaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jon.70011\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neuroimaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jon.70011","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Reliability of Central Vein Sign Imaging With 3T FLAIR* in a Multicenter Study.
Background and purpose: The central vein sign (CVS) is a diagnostic imaging biomarker for multiple sclerosis (MS). FLAIR* is a combined MRI contrast that provides high conspicuity for CVS at 3 Tesla (3T), enabling its sensitive and accurate detection in clinical settings. This study evaluated whether CVS conspicuity of 3T FLAIR* is reliable across imaging sites and MRI vendors and whether gadolinium (Gd) contrast increases CVS conspicuity.
Methods: A cross-sectional, multicenter study recruited adults referred for possible diagnosis of MS at 10 sites. FLAIR* contrast was generated using high-resolution T2*-weighted (acquired pre- and post-injection of Gd) and T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) brain images at 3T from two MRI vendors. Lesions and veins were segmented to compute lesion-to-vein contrast-to-noise ratio (CNRlesion-to-vein), a quantitative measure of CVS conspicuity. CNRlesion-to-vein measures for pre- and post-Gd FLAIR* were compared across sites and vendors.
Results: Eighty-seven participants from nine sites were included in the analysis. There was no significant difference in mean CNRlesion-to-vein between sites for pre-Gd (p-value = 0.07) or post-Gd (p-value = 0.27) FLAIR*. There were also no significant differences between vendors for pre-Gd (p-value = 0.10) or post-Gd (p-value = 0.31) FLAIR*. Patient-level pairwise differences in CNRlesion-to-vein between pre-Gd and post-Gd FLAIR* revealed a significant increase for post-Gd FLAIR* (p-value < 0.001).
Conclusions: CVS conspicuity on 3T FLAIR* is consistent across imaging sites and MRI vendors. Moreover, Gd-based contrast agent significantly improved CVS conspicuity on 3T FLAIR*. These findings support the implementation of FLAIR* in clinical settings for MS.
期刊介绍:
Start reading the Journal of Neuroimaging to learn the latest neurological imaging techniques. The peer-reviewed research is written in a practical clinical context, giving you the information you need on:
MRI
CT
Carotid Ultrasound and TCD
SPECT
PET
Endovascular Surgical Neuroradiology
Functional MRI
Xenon CT
and other new and upcoming neuroscientific modalities.The Journal of Neuroimaging addresses the full spectrum of human nervous system disease, including stroke, neoplasia, degenerating and demyelinating disease, epilepsy, tumors, lesions, infectious disease, cerebral vascular arterial diseases, toxic-metabolic disease, psychoses, dementias, heredo-familial disease, and trauma.Offering original research, review articles, case reports, neuroimaging CPCs, and evaluations of instruments and technology relevant to the nervous system, the Journal of Neuroimaging focuses on useful clinical developments and applications, tested techniques and interpretations, patient care, diagnostics, and therapeutics. Start reading today!