非共面容积调制弧线疗法与螺旋断层疗法在海马回避全脑放射治疗中的剂量学比较

IF 1.7 4区 综合性期刊 Q2 MULTIDISCIPLINARY SCIENCES Journal of Radiation Research and Applied Sciences Pub Date : 2025-02-17 DOI:10.1016/j.jrras.2025.101372
Xiao-Long Cheng, Ji-Ping Liu, Bin-Bing Wang, Long Sun
{"title":"非共面容积调制弧线疗法与螺旋断层疗法在海马回避全脑放射治疗中的剂量学比较","authors":"Xiao-Long Cheng,&nbsp;Ji-Ping Liu,&nbsp;Bin-Bing Wang,&nbsp;Long Sun","doi":"10.1016/j.jrras.2025.101372","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Whole-brain radiotherapy(WBRT) can alleviate symptoms in patients with brain metastases. However, WBRT may damage the hippocampus.The helical tomotherapy (HT) presents a significant dosimetric advantage in the hippocampus avoidance WBRT(HA-WBRT). How to design linear accelerator radiation therapy plan for HA-WBRT is a challenge for medical physicists.</div></div><div><h3>Objective</h3><div>The aim of this study is to investigate the dosimetric differences between noncoplanar VMAT(NC-VMAT) and HT in HA-WBRT, exploring the feasibility of NC-VMAT for HA-WBRT.</div></div><div><h3>Methods</h3><div>Fifteen patients with HA-WBRT were chosen randomly. For each patient, the Monaco TPS was used to design four distinct NC-VMAT plans based on the quantity of non-coplanar arcs (NC-VMATA, NC-VMATB,NC-VMATC,NC-VMATD) for HA-WBRT, totaling 60 plans. The HT TPS was used to generate HT plans, totaling 15 plans.The prescribed dose was 30 Gy in 10 fractions. Treatment plans were established based on the RTOG 0933 criteria.Under the premise that the 95% isodose curve covers the target area, dose-volume histogram(DVH) was applied to evaluate the WB-PTV, CI, HI, Dmax, Dmean, Dmin and doses of OARs in NC-VMAT and HT plans. Paired <em>t</em>-test was performed to compare the differences between each two radiation therapy plans, and p &lt; 0.05 was considered statistically significant.</div></div><div><h3>Results</h3><div>The RTOG0933 criteria could not be satisfied in NC-VMATA with 1 non-coplanar beam. NC-VMATB with 2 non-coplanar beams, the condition Dmax&lt;16 Gy was not satisfied for 8 case in the hippocampus. NC-VMATC with 3 non-coplanar beams, the condition D98% &gt; 25 Gy was not satisfied for 5 case in the WB-PTV. NC-VMATD with 4 non-coplanar beams and HT, all plans complied with the \"Per protocol\" requirements in the RTOG 0933 standard.We compared NC-VMATD with HT and found that there were no differences in the D98% and D2% of WB-PTV. However, the HT was significantly superior to NC-VMATD in terms of CI, HI, Dmean in HP, Dmax in Lens, Dmean in eyes (p &lt; 0.05). The Dmax, D100% of HP and the dosimetry of other OARs had no significant difference (p &gt; 0.05).In contrast, the average beam on time in NC-VMATD was greater advantage(506s Vs 687s, p &lt; 0.05). NC-VMAT and HT planning templates were devised, which facilitated physicists in rapidly designing high-quality HA-WBRT plans.</div></div><div><h3>Conclusion</h3><div>NC-VMAT proves to be effective in managing HA-WBRT.The plan quality improved along with the increase of non-coplanar arcs. NC-VMAT(one full arc and four noncoplanar partial arcs) with FFF irradiation mode is most recommended plan design pattern. NC-VMAT provides a practical clinical treatment option for HA-WBRT based on linear accelerators.</div></div>","PeriodicalId":16920,"journal":{"name":"Journal of Radiation Research and Applied Sciences","volume":"18 2","pages":"Article 101372"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dosimetric comparison of noncoplanar volumetric modulated arc therapy and helical tomotherapy in whole brain radiotherapy with hippocampus avoidance\",\"authors\":\"Xiao-Long Cheng,&nbsp;Ji-Ping Liu,&nbsp;Bin-Bing Wang,&nbsp;Long Sun\",\"doi\":\"10.1016/j.jrras.2025.101372\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Whole-brain radiotherapy(WBRT) can alleviate symptoms in patients with brain metastases. However, WBRT may damage the hippocampus.The helical tomotherapy (HT) presents a significant dosimetric advantage in the hippocampus avoidance WBRT(HA-WBRT). How to design linear accelerator radiation therapy plan for HA-WBRT is a challenge for medical physicists.</div></div><div><h3>Objective</h3><div>The aim of this study is to investigate the dosimetric differences between noncoplanar VMAT(NC-VMAT) and HT in HA-WBRT, exploring the feasibility of NC-VMAT for HA-WBRT.</div></div><div><h3>Methods</h3><div>Fifteen patients with HA-WBRT were chosen randomly. For each patient, the Monaco TPS was used to design four distinct NC-VMAT plans based on the quantity of non-coplanar arcs (NC-VMATA, NC-VMATB,NC-VMATC,NC-VMATD) for HA-WBRT, totaling 60 plans. The HT TPS was used to generate HT plans, totaling 15 plans.The prescribed dose was 30 Gy in 10 fractions. Treatment plans were established based on the RTOG 0933 criteria.Under the premise that the 95% isodose curve covers the target area, dose-volume histogram(DVH) was applied to evaluate the WB-PTV, CI, HI, Dmax, Dmean, Dmin and doses of OARs in NC-VMAT and HT plans. Paired <em>t</em>-test was performed to compare the differences between each two radiation therapy plans, and p &lt; 0.05 was considered statistically significant.</div></div><div><h3>Results</h3><div>The RTOG0933 criteria could not be satisfied in NC-VMATA with 1 non-coplanar beam. NC-VMATB with 2 non-coplanar beams, the condition Dmax&lt;16 Gy was not satisfied for 8 case in the hippocampus. NC-VMATC with 3 non-coplanar beams, the condition D98% &gt; 25 Gy was not satisfied for 5 case in the WB-PTV. NC-VMATD with 4 non-coplanar beams and HT, all plans complied with the \\\"Per protocol\\\" requirements in the RTOG 0933 standard.We compared NC-VMATD with HT and found that there were no differences in the D98% and D2% of WB-PTV. However, the HT was significantly superior to NC-VMATD in terms of CI, HI, Dmean in HP, Dmax in Lens, Dmean in eyes (p &lt; 0.05). The Dmax, D100% of HP and the dosimetry of other OARs had no significant difference (p &gt; 0.05).In contrast, the average beam on time in NC-VMATD was greater advantage(506s Vs 687s, p &lt; 0.05). NC-VMAT and HT planning templates were devised, which facilitated physicists in rapidly designing high-quality HA-WBRT plans.</div></div><div><h3>Conclusion</h3><div>NC-VMAT proves to be effective in managing HA-WBRT.The plan quality improved along with the increase of non-coplanar arcs. NC-VMAT(one full arc and four noncoplanar partial arcs) with FFF irradiation mode is most recommended plan design pattern. NC-VMAT provides a practical clinical treatment option for HA-WBRT based on linear accelerators.</div></div>\",\"PeriodicalId\":16920,\"journal\":{\"name\":\"Journal of Radiation Research and Applied Sciences\",\"volume\":\"18 2\",\"pages\":\"Article 101372\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2025-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiation Research and Applied Sciences\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1687850725000846\",\"RegionNum\":4,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research and Applied Sciences","FirstCategoryId":"103","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1687850725000846","RegionNum":4,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dosimetric comparison of noncoplanar volumetric modulated arc therapy and helical tomotherapy in whole brain radiotherapy with hippocampus avoidance

Background

Whole-brain radiotherapy(WBRT) can alleviate symptoms in patients with brain metastases. However, WBRT may damage the hippocampus.The helical tomotherapy (HT) presents a significant dosimetric advantage in the hippocampus avoidance WBRT(HA-WBRT). How to design linear accelerator radiation therapy plan for HA-WBRT is a challenge for medical physicists.

Objective

The aim of this study is to investigate the dosimetric differences between noncoplanar VMAT(NC-VMAT) and HT in HA-WBRT, exploring the feasibility of NC-VMAT for HA-WBRT.

Methods

Fifteen patients with HA-WBRT were chosen randomly. For each patient, the Monaco TPS was used to design four distinct NC-VMAT plans based on the quantity of non-coplanar arcs (NC-VMATA, NC-VMATB,NC-VMATC,NC-VMATD) for HA-WBRT, totaling 60 plans. The HT TPS was used to generate HT plans, totaling 15 plans.The prescribed dose was 30 Gy in 10 fractions. Treatment plans were established based on the RTOG 0933 criteria.Under the premise that the 95% isodose curve covers the target area, dose-volume histogram(DVH) was applied to evaluate the WB-PTV, CI, HI, Dmax, Dmean, Dmin and doses of OARs in NC-VMAT and HT plans. Paired t-test was performed to compare the differences between each two radiation therapy plans, and p < 0.05 was considered statistically significant.

Results

The RTOG0933 criteria could not be satisfied in NC-VMATA with 1 non-coplanar beam. NC-VMATB with 2 non-coplanar beams, the condition Dmax<16 Gy was not satisfied for 8 case in the hippocampus. NC-VMATC with 3 non-coplanar beams, the condition D98% > 25 Gy was not satisfied for 5 case in the WB-PTV. NC-VMATD with 4 non-coplanar beams and HT, all plans complied with the "Per protocol" requirements in the RTOG 0933 standard.We compared NC-VMATD with HT and found that there were no differences in the D98% and D2% of WB-PTV. However, the HT was significantly superior to NC-VMATD in terms of CI, HI, Dmean in HP, Dmax in Lens, Dmean in eyes (p < 0.05). The Dmax, D100% of HP and the dosimetry of other OARs had no significant difference (p > 0.05).In contrast, the average beam on time in NC-VMATD was greater advantage(506s Vs 687s, p < 0.05). NC-VMAT and HT planning templates were devised, which facilitated physicists in rapidly designing high-quality HA-WBRT plans.

Conclusion

NC-VMAT proves to be effective in managing HA-WBRT.The plan quality improved along with the increase of non-coplanar arcs. NC-VMAT(one full arc and four noncoplanar partial arcs) with FFF irradiation mode is most recommended plan design pattern. NC-VMAT provides a practical clinical treatment option for HA-WBRT based on linear accelerators.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
5.90%
发文量
130
审稿时长
16 weeks
期刊介绍: Journal of Radiation Research and Applied Sciences provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and applications of nuclear, radiation and isotopes in biology, medicine, drugs, biochemistry, microbiology, agriculture, entomology, food technology, chemistry, physics, solid states, engineering, environmental and applied sciences.
期刊最新文献
Thermally radiative flow of non-Newtonian Rabinowitsch fluid through a permeable artery with multiple stenoses of varying shapes Applications to medical and failure time data: Using a new extension of the extended exponential model Assessment of radiobiological impacts of threshold doses of alpha particles on A549 human lung cancer cells following direct irradiation exposure Irreversibility analysis and thermal performance of quadratic radiation and Darcy-Forchheimer flow over non-isothermal needle with velocity slip: Effects of aggregation and non-aggregation dynamics Robust estimator for estimation of population mean under PPS sampling: Application to radiation data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1